Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 267 for “"PENETRATION TEST"”.
-
The piezometer cone penetration test
Deep quasi-static cone penetration tests in saturated soils can develop large excess pore pressures. The level and sign of the excess pore pressures depend on the volume change characteristics, the strength and the permeability of the soil. The recent addition of pore pressure measurements during …
-
Energy measurements and correlations of the standard penetration test (SPT) and the becker penetration test (BPT)
The Standard penetration test (SPT) and the Becker penetration test (BPT) are two of the most widely used in-situ tests in North America. The SPT is most commonly used in sands and silty sands, while the BPT, being a large-scale penetration test, is more useful in gravelly soils. Both tests involve …
-
Energy transfer and grain size effects during the Standard Penetration Test (SPT) and Large Penetration Test (LPT)
The Standard Penetration Test (SPT) is the most widely used in-situ soil test in the world. "Large Penetration Test" (LPT) is a term used to describe any scaled up version of the SPT. Several types of LPT have been developed around the world for the purpose of characterizing gravel deposits, as SPT …
-
The cone penetration test in unsaturated sands
The cone penetration test (CPT) is widely used for in situ characterization of saturated or dry soils based on correlations developed for saturated/dry conditions. However, no methods currently exist for interpretation of CPT data in unsaturated soils. This study advances both experimental and …
-
Soil Specific Interpretation of the Cone Penetration Test
The Cone Penetration Test has quickly and rightfully claimed its position as a popular site investigation tool in geotechnical engineering. Like all penetration tests, CPT results need to be interpreted into engineering parameters. In granular soils, the state parameter, which is the key driver of …
-
Standard penetration test correlations for Las Vegas soils
Standard penetration tests (SPT) are used to approximate soil properties including the consistency, cohesion and the internal angle of friction. Due to the frequency of cemented sands, gravel and clay in the Las Vegas Valley, the generally accepted SPT correlations vary from actual local …
-
An analytical study of the cone penetration test
The quasi-static penetration of a cone penetrometer into clay can be formulated as a steady state problem by considering a steady flow of soil past a stationary cone. The soil velocities are estimated from the flow field of an inviscid fluid, and the incompressibility condition is achieved by …
-
The Cone Penetration Test in Unsaturated Silty Sands
The cone penetration test (CPT) is widely used for in-situ characterization of saturated or dry soils for which interpretation methods are well established. The CPT is also performed in unsaturated soils yet very little is known about how to interpret the recovered results. The few published …
-
Compressibility-based interpretation of cone penetration test data
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-03-28 without embargo terms
-
Interpretation of cone penetration test data for underconsolidated clay
In this study, cone penetration test data is correlated to vane shear and triaxial undrained shear strength test data for a saturated and underconsolidated marine clay. It is shown that cone penetration test data not corrected for pore pressures underestimates undrained shear strength. …
-
Development and verification of a miniature cone penetration test
… were to design and validate a miniature cone penetration test (MCPT) system for testing fine-grained soils. The system included a commercially-available miniature piezocone and a 300-mm-diameter, rigid-wall, calibration chamber. Three different materials were used in this study: (i) Ottawa …
-
Bearing capacity of piles from cone penetration test data.
… contain results of full-scale pile loading tests, soil characteristics, and CPT soundings which were performed close to the pile locations. The proposed method relates both the pile unit toe resistance and the unit shaft resistance to the effective cone point resistance, q$\rm\sb{E}.$ The …
-
A Model-driven Penetration Test Framework for Web Applications
Penetration testing is widely used in industry as a test method for web application security assessment. However, penetration testing is often performed late in a software development life cycle as an isolated task and usually requires specialized security experts. There is no well-defined test …
-
Dilatancy characterization of sands using the resistivity cone penetration test
… engineers to place increased reliance on in situ tests. One such test which is gaining acceptance in the geotechnical profession is the cone penetration test (CPT). As with other in situ tests, the CPT can be used to predict dilatancy behaviour of sands based on empirical correlations. As with …
-
Cone Penetration Test in Unsaturated Soil with Matric Suction Measurement
… the use of 3D scanner for shrinkage limit testing of soils are presented; the second half of this dissertation presents the findings related to the chamber tests conducted which measures the matric suction of the unsaturated soil during cone penetration tests. Part I: Shrinkage curve …
-
Dynamic analysis of dynamic cone penetration test for subgrade compaction assessment
… weight obtained from a laboratory compaction test. Most DOTs typically require that the in-place dry unit weight for compacted soil be over 95% of the laboratory maximum dry unit weight obtained from Standard Proctor compaction test results. Nuclear gauges may be used to determine the in-place …
-
Dynamic analysis of dynamic cone penetration test for subgrade compaction assessment
… weight obtained from a laboratory compaction test. Most DOTs typically require that the in-place dry unit weight for compacted soil be over 95% of the laboratory maximum dry unit weight obtained from Standard Proctor compaction test results. Nuclear gauges may be used to determine the in-place …
-
Strength, liquefaction and cone penetration test results in unsaturated silty tailings
… and how they may be characterised using the cone penetration test (CPT), when unsaturated. The focus is on loose states and high degrees of saturation. Firstly the tailings are characterised, using triaxial tests involving constant suction and constant mass (closed system) conditions to establish …
Page 1 of 14