Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 73 for “"PET-Scanner"”

  1. Impact of preclinical PET scanner characteristics on the overall image quality

    … dernières décennies, les progrès de la modalité PET et le développement de modèles animaux de maladies humaines ont conduit au développement de la technologie PET dédiée aux petits animaux. En raison de la différence de taille entre l’homme et la souris, les scanners pour petits animaux …

    star-france Repository record for Impact of preclinical PET scanner characteristics on the overall image quality (opens in a new tab)

  2. Design of the Cherenkov TOF whole-body PET scanner using GATE simulation

    … sur la simulation GATE pour la configuration du scanner suivante: cristal de fluorure de plomb attaché à un photomultiplicateur à micro-canaux. C’est un cristal de haute densité, transparent pour les photons ultraviolet, et possède la fraction photoélectrique la plus élevé de 46%. Le …

    star-france Repository record for Design of the Cherenkov TOF whole-body PET scanner using GATE simulation (opens in a new tab)

  3. A Machine Learning Approach to Estimate the Annihilation Photon Interactions Inside the Scintillator of a PET Scanner

    … (SPECT) or by positron emission tomography (PET) scanners. SPECT uses gamma rays as tracer but gives a weaker contrast and spatial resolution compared to a PET scanner which uses positrons as tracer. PET scans show the metabolic changes occurring at the cellular level in an organ or a tissue. …

    wvu Repository record for A Machine Learning Approach to Estimate the Annihilation Photon Interactions Inside the Scintillator of a PET Scanner (opens in a new tab)

  4. System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification

    This thesis develops and validates a PET-based framework for online proton-beam range verification in small-animal models, with an extension to radioactive ion beams. A novel spherical in-beam PET scanner, composed of 56 pyramidal-stepped DOI-capable LYSO scintillator blocks, was designed and …

    lmu-germany Repository record for System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification (opens in a new tab)

  5. Studying The Clinical And Research Applications Of The Pennpet Explorer, A Long Axial Field-Of-View Pet Scanner

    … the long axial field-of-view (AFOV) PennPET Explorer scanner and studies the benefits for clinical and research applications using both measurements and Monte-Carlo simulations. The significant increase in photon sensitivity from extending the standard AFOV of a PET scanner by 3-6 times …

    penn Repository record for Studying The Clinical And Research Applications Of The Pennpet Explorer, A Long Axial Field-Of-View Pet Scanner (opens in a new tab)

  6. Evaluation of Inveon Pre-Clinical Positron Emission Tomography (PET) Scanner Geant4 Application for Tomographic Imaging (GATE) Model for Multi-Positron Emission Particle Tracking (M-PEPT)

    … Pre-Clinical Positron Emission Tomography (PET) scanner, and the scan data are sent to Multi-Positron Emission Particle Tracking (M-PEPT) software to recreate the particle track. A Geant4 Application for Tomographic Imaging (GATE) model of the Inveon is used to simulate the scanner response …

    utk-theses Repository record for Evaluation of Inveon Pre-Clinical Positron Emission Tomography (PET) Scanner Geant4 Application for Tomographic Imaging (GATE) Model for Multi-Positron Emission Particle Tracking (M-PEPT) (opens in a new tab)

  7. Analytic three dimensional image reconstruction from projections

    … that was developed for a proposed volume-imaging PET scanner. The development of the algorithm was motivated by the scanner's ability to collect an order of magnitude more data than current PET systems and the lack of an efficient algorithm that could use the extra data. The algorithm is based on …

    ubc Repository record for Analytic three dimensional image reconstruction from projections (opens in a new tab)

  8. Monte-Carlo simulations of positron emission tomography based on liquid xenon detectors

    … study the expected performance of a small animal PET scanner in comparison with a simulated conventional small animal scanner (LSO Focus 120). A NEMA-like cylinder phantom and an image contrast phantom were simulated with both scanners to compare performance characteristics. A Compton …

    ubc Repository record for Monte-Carlo simulations of positron emission tomography based on liquid xenon detectors (opens in a new tab)

  9. Simulation of AnnPET for Neural Network Training and System Performance Benchmarking

    … MC simulations of Positron Emission Tomography (PET) scanners have typically been used to model the performance of new systems. The imaging group in the Department of Radiology have developed a unique detector design for a pre- clinical PET scanner that utilizes a single, continuous annulus of …

    wvu Repository record for Simulation of AnnPET for Neural Network Training and System Performance Benchmarking (opens in a new tab)

  10. A Geant4 Simulation Study Of A Xenon-Doped Liquid Argon, Full-Body, Time-of-Flight Positron Emission Tomography Scanner To Understand Its Performance And Noise Profile

    Positron Emission Tomography (PET) is used to observe metabolic processes within living tissue. It works by reconstructing the annihilation origin of incident gamma rays produced by a positron emitting radiotracer. This field of nuclear imaging has seen a steady improvement of PET imaging largely …

    houston Repository record for A Geant4 Simulation Study Of A Xenon-Doped Liquid Argon, Full-Body, Time-of-Flight Positron Emission Tomography Scanner To Understand Its Performance And Noise Profile (opens in a new tab)

  11. Development of a novel method to estimate kinetic micro-parameters in dynamic whole-body PET imaging protocols

    … based on a typical Positron Emission Tomography (PET) scanner, a multi-pass multi-bed scanning protocol is necessary because of the limited axial field of view. Such a protocol introduces loss of early dynamics in the time-activity curves (TACs) and sparsity in TAC measurements; thus inducing …

    ubc Repository record for Development of a novel method to estimate kinetic micro-parameters in dynamic whole-body PET imaging protocols (opens in a new tab)

  12. An algorithm for automatic crystal identification in pixelated scintillation detectors using thin plate splines and Gaussian mixture models

    Positron emission tomography (PET) is a non-invasive imaging technique which utilizes positron-emitting radiopharmaceuticals (PERs) to characterize biological processes in tissues of interest. A PET scanner is usually composed of multiple scintillation crystal detectors placed in a ring so as to …

    manitoba Repository record for An algorithm for automatic crystal identification in pixelated scintillation detectors using thin plate splines and Gaussian mixture models (opens in a new tab)

  13. First results from the Time-of-Flight PET for proton therapy

    … in the patient. To this end, the Time-of-Flight PET for Proton Therapy (TPPT) consortium has constructed and partially commissioned an in-line Positron Emission Tomography (PET) scanner to monitor the activity of Positron Emitting Species (PES) produced as a result of Proton Beam interactions …

    texas Repository record for First results from the Time-of-Flight PET for proton therapy (opens in a new tab)

  14. System Solution for In-Beam Positron Emission Tomography Monitoring of Radiation Therapy

    In-beam Positron Emission Tomography (PET) is a system for monitoring high precision radiation therapy which is in the most cases applied to the tumors near organs at risk. High quality and fast availability of in-beam PET images are, therefore, extremely important for successful verification of …

    qucosa-diss Repository record for System Solution for In-Beam Positron Emission Tomography Monitoring of Radiation Therapy (opens in a new tab)

  15. Development of stopping rule methods for the MLEM and OSEM algorithms used in PET image reconstruction

    … reconstruction positron emission tomography (PET). The development of the stopping rules is based on the study of the properties of both algorithms. Analyzing their mathematical expressions, it can be observed that the pixel updating coefficients (PUC) play a key role in the upgrading process …

    patras-thes Repository record for Development of stopping rule methods for the MLEM and OSEM algorithms used in PET image reconstruction (opens in a new tab)

  16. Development of stopping rule methods for the MLEM and OSEM algorithms used in PET image reconstruction

    … reconstruction positron emission tomography (PET). The development of the stopping rules is based on the study of the properties of both algorithms. Analyzing their mathematical expressions, it can be observed that the pixel updating coefficients (PUC) play a key role in the upgrading process …

    greece Repository record for Development of stopping rule methods for the MLEM and OSEM algorithms used in PET image reconstruction (opens in a new tab)

  17. Event-Driven Motion Compensation in Positron Emission Tomography: Development of a Clinically Applicable Method

    Positron emission tomography (PET) is a well-established functional imaging method used in nuclear medicine. It allows for retrieving information about biochemical and physiological processes in vivo. The currently possible spatial resolution of PET is about 5 mm for brain acquisitions and about 8 …

    qucosa-diss Repository record for Event-Driven Motion Compensation in Positron Emission Tomography: Development of a Clinically Applicable Method (opens in a new tab)

  18. IN-PIXEL TIME DIGITAL CONVERTER FOR TIME-OF-FLIGHT PET IMAGING

    … of patients. Positron emission tomography (PET) imaging, as one of the recent imaging technologies, provides imaging from cellular-level metabolic changes in tissues. This gives PET imaging a substantial lead in detecting disease in their very early stages. PET imaging provides high …

    mcmaster Repository record for IN-PIXEL TIME DIGITAL CONVERTER FOR TIME-OF-FLIGHT PET IMAGING (opens in a new tab)

  19. Modellbasierte Korrektur der Streustrahlung in der Positronen-Emissions-Tomographie

    In der Positronenemissionstomographie (PET) hat sich durch den Wegfall abschirmender Septen beim Übergang von 2D zu 3D Messungen das Problem des Streuanteils in den gemessenen Projektionen deutlich verschärft. Gewöhnlich wird der Streuanteil unter Verwendung eines Streumodells geschätzt und zur …

    heid-diss Repository record for Modellbasierte Korrektur der Streustrahlung in der Positronen-Emissions-Tomographie (opens in a new tab)