Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 108 for “"PH measurement"”

  1. Reference Electrode Techniques for Solid State Potentiometric pH Measurement

    … ever made to the conventional potentiometric pH measurement system. This thesis reports on the experimental investigation of several prototype solid state reference electrodes which were designed to eliminate the reliance of conventional potentiometric specific ion glass electrode techniques …

    marquette Repository record for Reference Electrode Techniques for Solid State Potentiometric pH Measurement (opens in a new tab)

  2. In situ local pH measurement of oxygen evolution reaction catalysts

    … pathways are strongly influenced by the local pH at the electrode electrolyte interface rather than the bulk electrolyte pH. This is particularly important for anion exchange membrane (AEM) water electrolyzers, where operation under reduced alkalinity or pure water feed can result in …

    ubc Repository record for In situ local pH measurement of oxygen evolution reaction catalysts (opens in a new tab)

  3. Preparation of a fibre optic sensor based on AgNp/silica composite for pH measurement

    The measurement of hydrogen ion concentration in a solution, commonly referred to as pH, holds significant importance in various industries. However, measuring pH under high-temperature and high-pressure (HTHP) conditions has posed a formidable challenge due to the lack of reliable sensors and …

    strathclyde Repository record for Preparation of a fibre optic sensor based on AgNp/silica composite for pH measurement (opens in a new tab)

  4. Chitosan membrane based mach zehnder and michelson interferometer with waist enlarged fusion taper for pH measurement.

    … have focused on fiber optic development for pH sensing because real time measuring of pH of blood is critical for the patient who is seriously ill. Among many medical biosensors, optical fiber for pH sensors belong many good points above all medical sensors. Especially, fiber optic can be …

    nanyang Repository record for Chitosan membrane based mach zehnder and michelson interferometer with waist enlarged fusion taper for pH measurement. (opens in a new tab)

  5. Development of a wireless sensor network equipped with ISFET pH measurement technology to facilitate monitoring of microalgae cultivation processes

    … environmental parameters such as temperature, pH, dissolved oxygen, nutrient content, and other factors should be monitored continuously. In a large scale cultivation facility, the problem of developing an appropriate instrumentation and control system is compounded by the need to collect …

    unr Repository record for Development of a wireless sensor network equipped with ISFET pH measurement technology to facilitate monitoring of microalgae cultivation processes (opens in a new tab)

  6. A CEST MRI METHOD TO MEASURE pH

    Tumor pH is an important biomarker in cancer. In the following chapters an approach to measure pH by Chemical Exchange Saturation Transfer (CEST) MRI is described. Chapter 1 presents and introduction to molecular imaging, the importance of tumor pH and existing methods of pH measurement by various …

    ohiolink Repository record for A CEST MRI METHOD TO MEASURE pH (opens in a new tab)

  7. Instrument for measuring pH with optical indicator thin film

    The aim of this thesis is to describe a novel pH measurement instrument and demonstrate its performance by measurements carried out with a prototype. pH measurement is one of the most common measurements in process industry, but despite the wide-spread use of the measurement, common pH measurement …

    aalto Repository record for Instrument for measuring pH with optical indicator thin film (opens in a new tab)

  8. On designing algorithms for controlling pH

    … and control can be used to improve regulation of pH.</p> <p>A novel mathematical model of neutralization is used which explicitly accounts for two separate sources of non-linearities in pH systems: the inherent non-linearity of the pH measurement and the variable and uncertain non-linearity of the …

    oxford Repository record for On designing algorithms for controlling pH (opens in a new tab)

  9. Spectrophotometric determination of pH and its influence in soils

    It would be beneficial to develop an alternative pH measurement technique for soils, since the standard glass electrode method suffers deficiencies with unpredictability in liquid junction potential, high drift and the necessity for electrode calibration with variable ionic strength solutions if …

    adelaide Repository record for Spectrophotometric determination of pH and its influence in soils (opens in a new tab)

  10. The Potential of pH as a Determinant of Muscle Fatigue During Steady-State Exercise

    … fatigue during steady state exercise, how is pH related to muscle fatigue, what technologies exist to measure pH during exercise, and what future steps must be taken to make use of this connection. This paper examines muscle fatigue as a whole, as well as the role pH plays in predicting the …

    oregon Repository record for The Potential of pH as a Determinant of Muscle Fatigue During Steady-State Exercise (opens in a new tab)

  11. Fabrication and characterization of ISFET for PH measurements

    … and characterized the ISFET devices for pH measurement. After electrical measurement on wafer-level to confine the wafer fabrication process, the fabricated wafer was cut into individual ISFET dice. The ISFET dice was then mounted on printing circuit board (PCB).

    nanyang Repository record for Fabrication and characterization of ISFET for PH measurements (opens in a new tab)

  12. Studies in process analysis and control in batch reactors

    … carried out in batch reactors. The problems of pH measurement and sampling, linked to the implementation of NMR and HPLC on-line analysers, are presented as key areas in this development work. Also, part of the engineering work surnmarised in this thesis assisted the work of other researchers …

    strathclyde Repository record for Studies in process analysis and control in batch reactors (opens in a new tab)

  13. Accuracy of Verification Methods for Gastric Feeding Tube Placement in Preterm Neonates

    … aspirates, auscultation of an air bolus, and pH measurement of aspirates, when compared to x-ray confirmation. Nurses have an obligation to use the most accurate and least stressful method of placement and verification of feeding tubes. Nurses are responsible for checking the feeding tube …

    sdstate Repository record for Accuracy of Verification Methods for Gastric Feeding Tube Placement in Preterm Neonates (opens in a new tab)

  14. Carbon Nanotube-Based Wearable Sweat Sensors; Design and Fabrication

    … real-time health monitoring. Few sensors exhibit pH measurement on skin due to interference by sodium chloride ions. This thesis presents a multiplexing wearable sweat sensor using single and multi-walled carbon nanotubes. The wearable device houses pH, humidity, temperature and sodium chloride …

    washington Repository record for Carbon Nanotube-Based Wearable Sweat Sensors; Design and Fabrication (opens in a new tab)

  15. Metabolic Imaging of Early Radiation-Induced Lung Injury Using Hyperpolarized 13C-Pyruvate in Rodent Lungs

    … treated patients. RILI proceeds in two distinct phases: a) early and reversible Radiation Pneumonitis (RP), and b) late and irreversible radiation fibrosis. Clinically, Dose Volume Histogram (DVH) parameters derived from radiation therapy planning stage are used to determine outcome and severity …

    uwo Repository record for Metabolic Imaging of Early Radiation-Induced Lung Injury Using Hyperpolarized 13C-Pyruvate in Rodent Lungs (opens in a new tab)

  16. The effect of pre-partum diet on the severity of post-partum ruminal acidosis in primiparous dairy cows

    … and precision of a new continuous ruminal pH measurement system 2) to determine the required frequency for pH electrode standardization and 3) to determine the effect of additional pre-partum concentrate when compared to NRC (2001) recommendations on post-partum ruminal acidosis in …

    sask Repository record for The effect of pre-partum diet on the severity of post-partum ruminal acidosis in primiparous dairy cows (opens in a new tab)

  17. Temperature and pH Imaging using Chemical Exchange Saturation Transfer (CEST) MRI Contrast

    … contrast was proposed to noninvasively measure physiological parameters including temperature and pH. Tissue temperature and pH are known markers of pathological processes in many diseases including stroke and cancer. CEST contrast can be generated using endogenous proteins and peptides …

    uwo Repository record for Temperature and pH Imaging using Chemical Exchange Saturation Transfer (CEST) MRI Contrast (opens in a new tab)

  18. The development of electrochemical sensors based on the use of different forms of carbon materials

    … carbon based materials such as pyrolytic graphite; carbon nanotubes and carbon fibre have been used for a number of analytical and fundamental investigations. The first research aim of this thesis is to develop sensors for the detection of chemical compounds in ginger and turmeric. Chapter 3 …

    oxford Repository record for The development of electrochemical sensors based on the use of different forms of carbon materials (opens in a new tab)

  19. Pourbaix diagrams at elevated temperatures: a study of Zn and Sn

    … oC coolant in CANDU reactors. The Pourbaix (EH-pH) diagram is a plot of electrochemical potential versus pH, which shows the domains of various metal species and by inference, corrosion susceptibility. Elevated temperature data for tin +II and tin +IV species were obtained using solid-aqueous …

    uoit Repository record for Pourbaix diagrams at elevated temperatures: a study of Zn and Sn (opens in a new tab)

  20. A UV-Visible-NIR, Time-Resolved Fluorescence Spectrometer for High-Pressure Biological Studies

    … a quartz capillary pressure cell, an avalanche photodiode (APD), a 1-GHz digital oscilloscope, a 1-nm-resolution spectrometer and a fast-gated intensified charge coupled device (ICCD). The system is characterized as a spectroscopic probe at high pressures. A high-pressure cell has been designed …

    ohiolink Repository record for A UV-Visible-NIR, Time-Resolved Fluorescence Spectrometer for High-Pressure Biological Studies (opens in a new tab)

Page 1 of 6