Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"PHITS"”.

  1. Determination of Dose From Light Charged Ions Relevant to Hadron Therapy Using the Particle and Heavy Ion Transport System (PHITS)

    … the Particle and Heavy Ion Transport System (PHITS), the dose and fragmentation particles from ions of 1H, 4He, 7Li, 12C, 16O, and 20Ne were found at varying depths in a water phantom. A water filled cylindrical phantom with a radius of 10 cm was used to mimic a human body. The energy of each …

    tamu Repository record for Determination of Dose From Light Charged Ions Relevant to Hadron Therapy Using the Particle and Heavy Ion Transport System (PHITS) (opens in a new tab)

  2. Simulation and Analysis of Human Phantoms Exposed to Heavy Charged Particle Irradiations Using the Particle and Heavy Ion Transport System (PHITS)

    … Particle and Heavy-Ion Transport code System (PHITS) was used to test the phantoms and their materials for their potential as human surrogates for heavy ion irradiation. Stopping powers and depth-dose distributions of heavy charged particles (HCPs) important to space research and medical …

    tamu Repository record for Simulation and Analysis of Human Phantoms Exposed to Heavy Charged Particle Irradiations Using the Particle and Heavy Ion Transport System (PHITS) (opens in a new tab)

  3. SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS

    … used in fixed industrial radiography. The PHITS Monte Carlo code was used to compute the appropriate concrete wall necessary to shield gamma radiation and the most effective material appropriate to shield neutron source. For the gamma radiation source, the shielding design took into …

    liege Repository record for SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS (opens in a new tab) Download PDF for SHIELDING DESIGN AND SAFETY MEASURES AROUND 60Co, 192Ir, AND 252Cf SOURCES IN INDUSTRIAL RADIOGRAPHY FACILITIES BASED ON PHITS MONTE CARLO SIMULATIONS (opens in a new tab)

  4. Simulace a měření neutronového toku pomocí Bonnerových sfér

    … simulací vytvořených prostřednictvím programu PHITS. První část práce je zaměřena na neutrony a s nimi spjatou problematikou jejich detekce, a následně se práce věnuje také typům neutronovým zdrojů. Další část práce je zaměřena na program PHITS, a to na jak jeho základní, tak i rozšířené …

    brno-tech Repository record for Simulace a měření neutronového toku pomocí Bonnerových sfér (opens in a new tab)

  5. Designing a Complex Fragmentation Block for Simulating the Galactic Environment by Using a Single Accelerator Beam in PHITS (Practicle and Heavy Ion Transport Code System)

    … - Particle and Heavy Ion Transport code System (PHITS) will be used. Calculations showed it is necessary to design a moderator block that contains two different thicknesses - one with a length less than 23 cm and one with a length greater than 23 cm. The thinner moderator will allow high-Z …

    tamu Repository record for Designing a Complex Fragmentation Block for Simulating the Galactic Environment by Using a Single Accelerator Beam in PHITS (Practicle and Heavy Ion Transport Code System) (opens in a new tab)

  6. STUDY OF SECONDARY PARTICLES PRODUCED FROM HEAVY-ION INTERACTIONS

    … with the model calculations accomplished by PHITS, FLUKA, and MCNP transport codes. The comparison results show that the physics models need improvements particularly in the predictions of 1) neutrons created from the <sup>4</sup>He interactions at the high-energy end of the spectra at each …

    utk-theses Repository record for STUDY OF SECONDARY PARTICLES PRODUCED FROM HEAVY-ION INTERACTIONS (opens in a new tab)

  7. Výpočetní analýza neutronových polí generovaných pokročilými spalačními terči

    … přičemž je pomocí výpočetních kódů TALYS, MCNP a PHITS studován vliv materiálového složení terče na energetické spektrum výsledného neutronového pole. Získané poznatky jsou na závěr vyhodnoceny a je navržen další výzkum této problematiky.

    brno-tech Repository record for Výpočetní analýza neutronových polí generovaných pokročilými spalačními terči (opens in a new tab)

  8. Actinium-225 Production via Proton Irradiation of Thorium-232

    … by the Monte Carlo radiation transport code PHITS to simulate the experimental data obtained from sixteen irradiations of thorium metal targets with 25-210 µA [microampere] proton beams ranging in energies from 77 to 192 MeV. Irradiations were conducted at Brookhaven National Laboratory (BNL) …

    utk-theses Repository record for Actinium-225 Production via Proton Irradiation of Thorium-232 (opens in a new tab)

  9. Design of an In-Vivo Gamma Ray Body Scanner for Assaying Biodistribution of Inhaled Radionuclide Contamination in Warfighters

    … The detector responses were simulated using PHITS Monte Carlo radiation transport code and validated through benchmark measurements with Polymethyl Methacrylate (PMMA) slab phantoms and laboratory check sources to cover a broad spectrum of gamma energies. Upon verification, mesh-type …

    gatech Repository record for Design of an In-Vivo Gamma Ray Body Scanner for Assaying Biodistribution of Inhaled Radionuclide Contamination in Warfighters (opens in a new tab)

  10. SIMULATIONS OF SPACE RADIATION INTERACTIONS WITH MATERIALS, WITH APPLICATION TO DOSE ESTIMATES FOR LUNAR SHELTER AND ABOARD THE INTERNATIONAL SPACE STATION

    … interactions are simulated using MCNPX and PHITS probabilistic codes. The energy loss and energy deposition within the shielding materials and in a phantom are calculated. The contributions of secondary particles produced by spallation reactions are identified. Recent experimental …

    unm Repository record for SIMULATIONS OF SPACE RADIATION INTERACTIONS WITH MATERIALS, WITH APPLICATION TO DOSE ESTIMATES FOR LUNAR SHELTER AND ABOARD THE INTERNATIONAL SPACE STATION (opens in a new tab)

  11. Thick-Target Measurements of Light Ion Yields Relevant to Radiation Transport Calculations

    … MCNP’s LAQGSM and ISABEL physics models, and the PHITS Monte Carlo code. Light ion yields were best modeled by MCNPX and PHITS for incident iron and helium projectiles, respectively, while light ion yields were well-modeled by both transport codes for proton projectiles. Overall, this experiment …

    utk-theses Repository record for Thick-Target Measurements of Light Ion Yields Relevant to Radiation Transport Calculations (opens in a new tab)

  12. Trendy ve vývoji stínících materiálů pro neutronové zdroje se zaměřením na doprovodné gama záření

    … materiálů. Simulace byly provedeny v programu PHITS a doplněny výpočty v nástroji Phy-X/PSD. Získané výsledky jsou následně vyhodnoceny a využity k porovnání stínicích vlastností jednotlivých materiálů.

    brno-tech Repository record for Trendy ve vývoji stínících materiálů pro neutronové zdroje se zaměřením na doprovodné gama záření (opens in a new tab)

  13. Double Differential Neutron Yields Produced by Proton, Helium, and Iron Interactions in Thick Aluminum Targets

    … thick-target yields and compared with PHITS and MCNP transport model calculations.</p> <p>Comparisons with PHITS and MCNP revealed inconsistencies at low to intermediate energies, in addition to overestimations of the experimental yields at the 10° high-energy peak. Wide-angle yields at …

    utk-theses Repository record for Double Differential Neutron Yields Produced by Proton, Helium, and Iron Interactions in Thick Aluminum Targets (opens in a new tab)

  14. Implementation of a Tetrahedral Mesh Phantom Geometry Library for EGSnrc

    … transport codes such as MCNP6, Geant4, and PHITS, are also capable of simulating the interaction of ionizing radiation with tetrahedral mesh phantoms. Tetrahedral mesh phantoms have a number of advantages over voxel phantoms including improved modelling fidelity and locally varying element …

    ottawa-retro Repository record for Implementation of a Tetrahedral Mesh Phantom Geometry Library for EGSnrc (opens in a new tab)

  15. Evaluation of fast neutron shielding effectiveness in light-element compounds

    … at 106 n/s intensity along with MCNPX and PHITS code simulations. The transmission factor in different experiments was found to vary from 11% up to 34% with increasing thickness. Simulation results were in reasonable agreement with experimental data and supported the conclusion that …

    uoit Repository record for Evaluation of fast neutron shielding effectiveness in light-element compounds (opens in a new tab)

  16. Thick-target neutron yields for intermediate-energy heavy ion experiments at NSRL

    … emulating the experiment using MCNP and PHITS were conducted to provide a comparison to the collected data and to bring any discrepancies in the models to light.This work seeks to both provide a detailed look at where the particle transport codes poorly predict the experimental results as …

    utk-theses Repository record for Thick-target neutron yields for intermediate-energy heavy ion experiments at NSRL (opens in a new tab)

  17. MONTE CARLO CHARACTERIZATION OF THE NUCLEAR RADIATION EMITTED BY THE SURFACE OF THE MOON

    … frequently used in space radiation applications: PHITS and HETC-HEDS. Finally, the generated spectra are applied to the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) instrument aboard the Lunar Reconnaissance Orbiter (LRO), which has been monitoring the lunar radiation environment …

    utk-theses Repository record for MONTE CARLO CHARACTERIZATION OF THE NUCLEAR RADIATION EMITTED BY THE SURFACE OF THE MOON (opens in a new tab)

  18. Theoretical performance analysis of a novel hemispherical tissue equivalent proportional counter for neutron monitoring and dosimetry

    … were conducted using the Monte Carlo code PHITS (V. 2.24) with both mono-energetic 2.5 MeV neutrons and the neutron spectrum of 252Cf-D2O moderated. In these neutron fields the hemispherical counter appears to be a good alternative to the reference spherical geometry, whereas the …

    uoit Repository record for Theoretical performance analysis of a novel hemispherical tissue equivalent proportional counter for neutron monitoring and dosimetry (opens in a new tab)

  19. Examination of secondary electrons generated by encapsulated gamma sources to improve contact dosimetry estimates

    … Monte Carlo radiation transport code PHITS (Particle and Heavy Ion Transport code System), to calculate the contact dose rate conversion factors for all of the encapsulated gamma sources presented in NCRP-40, taking into account the dose from both gamma rays and secondary electrons. …

    uoit Repository record for Examination of secondary electrons generated by encapsulated gamma sources to improve contact dosimetry estimates (opens in a new tab)

Page 1 of 2