Particle Image Velocimetry (PIV) for Positron Emission Particle Tracking (PEPT) and Turbulence Modeling Validation
<p>A Particle Image Velocimetry (PIV) experiment is designed and data collected with intention to validate Positron Emission Particle Tracking (PEPT) methods. The PIV data are collected in a narrow rectangular channel for flow Reynolds number near 20,000. The narrow channel and attendant pump, …
-
COMPARISON BETWEEN PARTICLE IMAGE VELOCIMETRY DATA AND COMPUTATIONAL FLUID DYNAMICS SIMULATIONS FOR AN IN-LINE SLOT AND TOOTH ROTOR-STATOR MIXER
… capabilities, analyzing the velocity field data due to the rotor-stator interactions is crucial. Experimental 2-D velocity data have previously been acquired using Particle Image Velocity (PIV) for an in-line IKA prototype mixer which contains single rows of 12 rotor teeth and 14 stator …
-
Particle image velocimetry in an advanced, serpentine jet engine inlet duct
… obtained to aid in the interpretation of the PIV data. Using these diagnostic techniques, the formation of a pair of counter-rotating vortices was revealed. Two-dimensional PIV measurements were conducted along 20 planes near the two bends of the duct model. All data was collected with an …
-
Improved Particle Image Velocimetry Methods in Large-Scale Production Wind Tunnels
Implementing particle image velocimetry (PIV) data collection in wind tunnel testing increases understanding of the model flow field by providing velocity field data, as compared to single-point velocity data produced by traditional measurement approaches. However, using PIV poses challenges for …
-
Uncertainty of Stereo PIV Calibration and Self-Calibration
Particle image velocimetry (PIV) is a widely used fluid measurement technique. Three dimensional PIV data or stereo PIV is acquired using two cameras. Stereo cameras are calibrated from camera coordinates, pixels, to real world units such as millimeters using calibration models. Stereo calibration …
-
An Experimental Study of the Effect of Reshock on the Inclined Interface Richtmyer-Meshkov Instability
… Mie scattering and particle image velocimetry (PIV) data was collected using a planar laser system and was used to compute mixing width, vorticity and circulation. Experimental cases were defined by the time which the interface was allowed to develop before reshock interaction. Cases 1, 2 and 3 …
-
The Effects of Lock-On and Quasi-Periodicity in a Bluff Body Wake using Cylindrical Moving Surface Actuators
… results a detailed grid search is performed and PIV data gathered for the baseline and actuated flow to investigate changes in the wake. Baseline characteristics and a methodology for analysis are first presented for the unactuated flow at a constant Reynolds number of 15,000. Key signatures of …
-
Exploration of turbulent separation over a CRM-HS model in a large scale wind tunnel
… was studied using particle image velocimetry (PIV) in Kirsten Wind Tunnel (KWT) at the University of Washington without the nacelle/pylon group. The experiments were conducted for a range of Reynolds numbers and Angles of Attack (AOA) using tuft flow visualization to determine test conditions …
-
Particle image velocimetry study of a skid steer loader cooling fan
… In this thesis, particle image velocimetry (PIV) is used to study airflow in a skid steer loader's cooling package with an emphasis on gaining insights into strategies for noise reduction. The centrifugal fan used in this package is installed in a blower housing with two outlets and one …
-
Exploration of stall dynamics on a high-speed CRM wing
… and Particle Image Velocimetry (PIV) in the 8 ft by 12 ft Kirsten Wind Tunnel (KWT) at the University of Washington. The tufts showed a leading edge–tip stall at every tested condition, with separation delayed to higher angles of attack at higher Reynolds numbers (Re). Approximate …
-
Particle Image Velocimetry (PIV) measurements in the wake of a cascade of compressor blades at stall
… through the use of a Particle Image Velocimeter (PIV). This examination was conducted from the trailing edge of the blade well into the wake region. Flow visualization techniques were used to observe and record the behavior of the region of flow separation. The PIV data showed that the separated …
-
Experimental study of low Reynolds number flow control devices: dynamic burst control plate and dynamic roughness
… measurements, and particle image velocimetry (PIV) data, it is shown that these devices have the ability to suppress the leading edge separation bubble at higher angles of attack than an airfoil without such devices. With the increased stall angle obtained through the use of these devices, lift …
-
A study of the flow within shallow, narrow cavities at low Reynolds numbers.
… by experimental investigation. Experimental data are obtained at low speed in both wind and water tunnels. The free stream Reynolds numbers are 3.4 x 10⁵ in air and 4.3 x 10⁴ in water. The ratio of cavity length (in the direction of the flow) to width to depth is l:w:d=6:2:1. The first …
-
Experimental studies of unstart dynamics in inlet/isolator configurations in a Mach 5 flow
… velocities up to about 300 m/s as measured by PIV. Both the schlieren imaging and PIV data suggest the dynamics and flow structure of the unstart process are dependent on inlet geometry. Furthermore, the PIV data indicate the unstart process to be highly three-dimensional. Finally, tripping the …
-
Numerical Investigation of Turbulent Flows Around a Helical Coil Steam Generator for an Advanced Small Modular Reactor Using Large Eddy Simulation
… results from particle image velocimetry (PIV) measurements are provided as validation data. In first-order statistics, both the LES and URANS simulation results have agreements with the PIV data in cases of streamwise direction velocity and z-vorticity; however, the spanwise direction …
-
Alteration of Wingtip Vortices using Wingtip Jets on Fixed Wings and Rotating Blades
… loads, while Particle Image Velocimetry (PIV) data are acquired at three chordwise locations to characterize the flow around the wingtip. The results demonstrate that the addition of wingtip jets increases both overall lift and drag, with the effects being more pronounced at lower …
-
Turbulent interactions with normal shocks and their effects on aluminum particle burn time
… of turbulence present was also studied using PIV methods to verify that it represents a signi cant di fference between the two conditions. The experiments were conducted in the UIUC heterogeneous shock tube facility. The test conditions were 10atm and 2500K after the refl ected shock for both …
-
Experimental and numerical study of Taylor-Couette flow
… a combination of particle image velocimetry (PIV) experimental data and computational fluid dynamics (CFD). Wavy vortex flow and modulated wavy vortex flow which are two flow regimes of Taylor-Couette flow are investigated using the PIV technique and power spectral density. In addition, the …
-
TIME-RESOLVED PARTICLE IMAGE VELOCIMETRY STUDY OF LATERAL JET IN SUPERSONIC CROSSFLOW
… time-resolved particle image velocimetry (TR-PIV). The project concentrated on shock-wave boundary-layer interaction induced by the penetration of the jet, to understand the low-frequency fluctuations and the related unsteadiness associated with the fuel jet injection process in a supersonic …
-
Sensor-based Temporal Superresolution: Application to turbulent separated flow over a three-dimensional Gaussian hill
… The lack of time-resolved experimental data further hampers the understanding of the three-dimensional unsteady dynamics. This thesis addresses these issues in two parts. First, a data-driven technique using high-rate surface-pressure sensors and long short-term memory (LSTM) neural …