Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"PIV measurement"”.

  1. Micro-PIV measurement of flow through forming fabrics

    This thesis describes an experimental investigation of the flow field upstream of forming fabrics that are typically used in the paper making process. Micro Particle Image Velocimetry was used to measure the velocity distribution upstream of a forming fabric. The velocity upstream of two different …

    ubc Repository record for Micro-PIV measurement of flow through forming fabrics (opens in a new tab) Download PDF for Micro-PIV measurement of flow through forming fabrics (opens in a new tab)

  2. Optical fiber coupled low power micro-PIV measurement of flow in microchambers : modeling, fabrication, testing and validation

    … applies micro-particle image velocimetry (oPIV) technique to measure the flow fields in microchambers using de-ionized water. Low power and optical fiber coupled micro PIV experimental system was developed and implemented in-house. This system utilizes an epi-f1uorescent microscope, seed …

    concordia Download PDF for Optical fiber coupled low power micro-PIV measurement of flow in microchambers : modeling, fabrication, testing and validation (opens in a new tab)

  3. Flow Past a Rotating Circular Cylinder

    … flow visualization (PTFV), hot-film anemometry measurement and particle image velocimetry (PIV) measurement. The lift and drag force exerting on the cylinder are measured using a load cell. The von Karman vortex street is observed and its characteristics are presented at low speed ratio (a < 3). …

    nus Repository record for Flow Past a Rotating Circular Cylinder (opens in a new tab) Download file for Flow Past a Rotating Circular Cylinder (opens in a new tab)

  4. Uncertainty of Stereo PIV Calibration and Self-Calibration

    Particle image velocimetry (PIV) is a widely used fluid measurement technique. Three dimensional PIV data or stereo PIV is acquired using two cameras. Stereo cameras are calibrated from camera coordinates, pixels, to real world units such as millimeters using calibration models. Stereo calibration …

    utahstate Repository record for Uncertainty of Stereo PIV Calibration and Self-Calibration (opens in a new tab)

  5. The influences of V-shaped ribs and spanwise system rotation on a turbulent square duct flow

    … using the particle image velocimetry (PIV) measurement, large-eddy simulation (LES) and direct numerical simulation (DNS). The PIV measurements were conducted in a water channel, and three different angled V-shaped (60°, 45° and 30°) and perpendicular (90°) ribs were considered. As a …

    manitoba Repository record for The influences of V-shaped ribs and spanwise system rotation on a turbulent square duct flow (opens in a new tab)

  6. AN EXPERIMENTAL INVESTIGATION ON SOLUTE NATURAL CONVECTION IN A VERTICAL HELE-SHAW CELL

    … and implementation of experimental measurement techniques in microfluidic systems, more specifically in a thin-gap device that is used as a model for a saturated porous medium. Initially, quantitative in-plane velocity measurement by means of particle image velocimetry (PIV) within …

    maryland Repository record for AN EXPERIMENTAL INVESTIGATION ON SOLUTE NATURAL CONVECTION IN A VERTICAL HELE-SHAW CELL (opens in a new tab)

  7. Turbine end-wall aerothermal management with engineered surface structure

    … measured by transient Infrared Thermography. PIV measurement was conducted to obtain the exit flow field. Computational fluid dynamics (CFD) simulations were performed using ANSYS FLUENT to compliment the experimental findings. The flow solver uses the finite volume method to solve the …

    city-london Download PDF for Turbine end-wall aerothermal management with engineered surface structure (opens in a new tab)

  8. Particle Image Velocimetry with Bluff Body and Jet in Cross-Flow Flame Holder Applications

    … In this study Particle Image Velocimetry (PIV) was used to acquire flow field and velocity information for a bluff body flame holder and a jet in cross-flow flame holder. The bluff body trials tested consisted of combustion of a premixed air and fuel flow with the purpose of improving …

    uconn-diss Repository record for Particle Image Velocimetry with Bluff Body and Jet in Cross-Flow Flame Holder Applications (opens in a new tab)

  9. Metachronal Locomotion: Swimming, Scaling, and Schooling

    … recording and planar particle image velocimetry (PIV) measurement, I report on kinematics of fast metachronal swimmer and constructive vortex interactions among its appendages and discuss its implications for improved performance regarding the swimming. Second, I show how hydrodynamic performance …

    usf Repository record for Metachronal Locomotion: Swimming, Scaling, and Schooling (opens in a new tab)

  10. STUDY OF AIR BUBBLE INJECTION INTO LAMINAR AND TURBULENT WATER FLOW THROUGH AN ANNULAR TEST SECTION

    … test section with a high speed video camera. A PIV measurement technique was also used to determine laminar and turbulent velocity profiles in the liquid stream. In this study, an efficient image processing methodology was used to obtain the velocity profiles, bubble size, shapes and trajectory …

    cuny Repository record for STUDY OF AIR BUBBLE INJECTION INTO LAMINAR AND TURBULENT WATER FLOW THROUGH AN ANNULAR TEST SECTION (opens in a new tab)

  11. Automatic Particle Image Velocimetry Uncertainty Quantification

    The uncertainty of any measurement is the interval in which one believes the actual error lies. Particle Image Velocimetry (PIV) measurement error depends on the PIV algorithm used, a wide range of user inputs, flow characteristics, and the experimental setup. Since these factors vary in time and …

    utahstate Repository record for Automatic Particle Image Velocimetry Uncertainty Quantification (opens in a new tab)

  12. Detailed Study of Flow and Surface Heat Transfer Enhancement Mechanism in the Presence of Dimples and/or Protrusions

    … by the combination of these two. Flow field measurements, in-and-around these features, are done using the stereoscopic PIV. The transient TLC method is used for local surface heat transfer measurement. Numerical simulations, steady RANS, URANS, and LES, are used in conjunction with …

    ucf Repository record for Detailed Study of Flow and Surface Heat Transfer Enhancement Mechanism in the Presence of Dimples and/or Protrusions (opens in a new tab)

  13. Binary drop coalescence in liquids.

    … before colliding. A dual-field high-speed PIV measurement system was employed to quantify drop trajectories and overall collision conditions while simultaneously examining detailed velocity fields near the collision interface. In the We range examined, for equal size drops, both rebounding …

    umn Repository record for Binary drop coalescence in liquids. (opens in a new tab)

  14. The Haemodynamics of a Stented Arteriovenous Fistula through Experiments and Flow Modelling

    … a Tomographic Particle Image Velocimetry (Tomo-PIV) measurement. The subsequent temporally resolved volumetric velocity field was phase-averaged to quantify fluctuations occurring over the inlet pulsatile conditions. It was noted that high turbulent kinetic energy (TKE) was generated at the JXA …

    unsw Repository record for The Haemodynamics of a Stented Arteriovenous Fistula through Experiments and Flow Modelling (opens in a new tab)

  15. Optical Diagnostic Measurements Investigating Periodic Exhaust Flow Features of a Rotating Detonation Combustor

    … (OH*-CL) and Particle Image Velocimetry (PIV). The experimental configuration features an annular RDC with a converging annulus exit nozzle designed to achieve high internal pressures and an aerospike center body at the annulus exit. The aerospike enables the flow field to adjust …

    alabama Repository record for Optical Diagnostic Measurements Investigating Periodic Exhaust Flow Features of a Rotating Detonation Combustor (opens in a new tab)

  16. Stacked Microchannel Heat Sinks for Liquid Cooling of Microelectronics Devices

    … the microchannels were characterized using Micro-PIV techniques. Microchannels of different width were fabricated in silicon, the smallest channel measuring 34 mm in width. Measurements were conducted at various channel depths. Measured velocity profiles at these depths were found to be in …

    gatech Repository record for Stacked Microchannel Heat Sinks for Liquid Cooling of Microelectronics Devices (opens in a new tab)

  17. An experimental investigation on wind turbine aeromechanics and wake interferences among multiple wind turbines

    … a high-resolution Particle Image Velocity (PIV) system was used to conduct detailed flow field measurements (i.e., both free-run and phase-locked flow fields measurements) to reveal the transient behavior of the unsteady wake vortices and turbulent flow structures behind wind turbines and to …

    iastate Repository record for An experimental investigation on wind turbine aeromechanics and wake interferences among multiple wind turbines (opens in a new tab)

  18. Particle Image Velocimetry Based Flow Characterization in a Randomly Packed Pebble Bed Core Geometry

    … core. By utilizing Particle Image Velocimetry (PIV) among the spheres, high-fidelity velocity measurements and Laser Induced Fluorescence (LIF) were carried out. In this facility, Matched Index of Refraction (MIR) method provides a clear non-intrusive view of the sphere void regions to analyze …

    tamu Repository record for Particle Image Velocimetry Based Flow Characterization in a Randomly Packed Pebble Bed Core Geometry (opens in a new tab)

  19. Novel cooling strategies for improved protection of gas turbine blades

    … a high-resolution Particle Image Velocimetry (PIV) system was used to conduct detailed flow field measurements to quantify the dynamic mixing process between the coolant streams and the mainstream flows over the test plates, Pressure Sensitive Paint (PSP) technique was used to map the …

    iastate Repository record for Novel cooling strategies for improved protection of gas turbine blades (opens in a new tab)

  20. An Investigation Into The Flow In Candu Fan Nozzles

    … simulations done on the same nozzle. Physical measurements were taken using a PIV laser system on the scaled down nozzle. Seven measurements planes were taken on two of the outlets of the nozzle at two different flowrates (0.2 kg/s and 0.1 kg/s). Given a single PIV measurement plane contains …

    mcmaster Repository record for An Investigation Into The Flow In Candu Fan Nozzles (opens in a new tab)

Page 1 of 2