Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"PLS calibration"”.

  1. Resonance Raman spectroscopy in the analysis of residual lignin and other unsaturated structures in chemical pulps

    … wood samples. Further, a partial least squares (PLS) model was developed to assist the determination of the characteristic UVRR bands of different lignin structures. The UVRRS-PLS method was further applied to interpret the more complex lignin spectra. The results correlated well with the results …

    aalto Repository record for Resonance Raman spectroscopy in the analysis of residual lignin and other unsaturated structures in chemical pulps (opens in a new tab)

  2. MEASUREMENT OF RARE EARTH AND URANIUM ELEMENTS USING LASER-INDUCED BREAKDOWN SPECTROSCOPY (LIBS) IN AN AEROSOL SYSTEM FOR NUCLEAR SAFEGUARDS APPLICATIONS

    … Ce and Gd lines, respectively. The univariate calibration curve for Ce using the peak intensities of the Ce 418.660 nm line was recommended and had an R2 value, LOD, and RMSECV of 0.994, 189 ppm, and 390 ppm, respectively. The recommended Gd calibration curve was generated using the peak areas …

    vcu Repository record for MEASUREMENT OF RARE EARTH AND URANIUM ELEMENTS USING LASER-INDUCED BREAKDOWN SPECTROSCOPY (LIBS) IN AN AEROSOL SYSTEM FOR NUCLEAR SAFEGUARDS APPLICATIONS (opens in a new tab)

  3. Assessment of novel measurement technologies for process monitoring and use of chemometric advances to facilitate their application

    … the spectrometer for in situ process monitoring. Calibration transfer between the two MIR spectrometers was also performed, demonstrating the ability to build a model in the laboratory for subsequent application to a process.;The instrumental stability of a low-field NMR spectrometer was …

    strathclyde Repository record for Assessment of novel measurement technologies for process monitoring and use of chemometric advances to facilitate their application (opens in a new tab)

  4. KINETIC MODELING OF DISSOLUTION AND CRYSTALLIZATION OF BATCH REACTIONS WITH IN SITU SPECTROSCOPIC MEASUREMENTS

    … in a slurry. Using a Partial Least-Squares (PLS) calibration, we were able to verify and validate the kinetic model. A temperature probe was also used to monitor heat changes involved in these experiments.

    ecu Repository record for KINETIC MODELING OF DISSOLUTION AND CRYSTALLIZATION OF BATCH REACTIONS WITH IN SITU SPECTROSCOPIC MEASUREMENTS (opens in a new tab)

  5. COMPOSITIONAL ANALYSIS OF CERIUM AND CESIUM IN RAPID SETTING CEMENT AS AN IMMOBILIZATION AGENT FOR NUCLEAR WASTE

    … analysis (PCA) and partial least squares (PLS) were applied to detect the surrogate elements (Ce (0.5 – 8 wt%) and Cs (0.5 – 4 wt%)) for nuclear materials captured in ceramic materials. The best calibration curves for Ce and Cs in samples were created using the peak areas of the Ce 571.8 nm …

    vcu Repository record for COMPOSITIONAL ANALYSIS OF CERIUM AND CESIUM IN RAPID SETTING CEMENT AS AN IMMOBILIZATION AGENT FOR NUCLEAR WASTE (opens in a new tab)

  6. Kinetika degradace inkjetových barviv

    … Z daných hodnôt bola vypočítaná kalibrácia (PLS metódou a metódou najmenších štvorcov). Na základe kalibrácie bola následne získaná predikcia úbytku jednotlivých atramentov v prijímacej vrstve na reálnych vzorkách. Zmeny v elektrónovej a molekulovej štruktúre boli analyzované pomocou FTIR a …

    brno-tech Repository record for Kinetika degradace inkjetových barviv (opens in a new tab)