Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 50 for “"PMU Measurements"”.

  1. On the application of PMU measurements to system stability analysis

    … to analyze power system stability by utilizing PMU measurements. As the current power system is operated close to its limits, stability is of high concern for both operators and customers. The implementation of phasor measurement units across the power system allows for accurate and fast …

    uiuc Repository record for On the application of PMU measurements to system stability analysis (opens in a new tab)

  2. Fast power network detection of topology change locations using PMU measurements

    … states obtained from phasor measurement units (PMUs). This scheme can be applied on reduced systems where parts of the network are not covered by PMU measurements. The scheme was tested during different outage events in the IEEE39-bus system. The obtained results validated the algorithm’s …

    utc Repository record for Fast power network detection of topology change locations using PMU measurements (opens in a new tab)

  3. Wide-area monitoring and control utilizing PMU measurements for a system protection scheme

    … paradigm; Phasor Measurement Units, or PMUs. PMUs bear high potential for wide-area system monitoring and control as well for conducting advanced engineering analysis. PMUs can provide time-synchronized high-resolution estimates of voltage and currents (both phase amplitude and angle) as …

    ubc Repository record for Wide-area monitoring and control utilizing PMU measurements for a system protection scheme (opens in a new tab) Download PDF for Wide-area monitoring and control utilizing PMU measurements for a system protection scheme (opens in a new tab)

  4. Renewable Energy Integrated Power System Stability Assessment with Validated System Model Based on PMU Measurements

    … transmission line parameters in the system with PMU measurements. The system transient stability assessment is conducted based on this validated model. The constrained stability region is estimated with Lyapunov functions family based method in the center of angles reference frame considering …

    vt Repository record for Renewable Energy Integrated Power System Stability Assessment with Validated System Model Based on PMU Measurements (opens in a new tab)

  5. Power System State Estimation Using Phasor Measurement Units

    … increment. In addition, phasor measurement unit (PMU) measurements are applied in state estimation to verify if they could solve the divergence problem and improve state estimation accuracy. The dissertation investigates the impacts of variations of line power flow increment and topology errors on …

    uky-thes Repository record for Power System State Estimation Using Phasor Measurement Units (opens in a new tab)

  6. Study of the utilization and benefits of phasor measurement units for large scale power system state estimation

    … of the use of the Phasor Measurement Units (PMU) on the state estimation problem. First, incorporation of the PMU measurements in a conventional state estimation program will be discussed. Then, the effect of adding PMU measurements on the state estimation solution accuracy will be studied. …

    tamu Repository record for Study of the utilization and benefits of phasor measurement units for large scale power system state estimation (opens in a new tab)

  7. Online Voltage Stability Monitoring and Control Using Limited Synchrophasor Measurements

    … the application of Phasor Measurement Units (PMUs), dispatchers are able to monitor long term voltage stability in a real time operational environment. This research addresses the critical issues by proposing three different methods. Voltage Stability Assessment Index (VSAI) is a Thévenin …

    vt Repository record for Online Voltage Stability Monitoring and Control Using Limited Synchrophasor Measurements (opens in a new tab)

  8. State and parameter estimation of power systems using phasor measurement units as bilinear system model

    … level. Including of Phasor Measurement Units (PMUs) along with current SCADA (Supervisory Control and Data Acquisition) system is an essential step towards realization of smart grids. PMUs can give synchronized measurements of voltage and current phasors from the grid, however their placement …

    ttu Repository record for State and parameter estimation of power systems using phasor measurement units as bilinear system model (opens in a new tab)

  9. Localization and control of very low-frequency oscillations in Ireland's power system

    … source location and detection algorithms to PMU measurements from the Irish system as well as studying model enhancements to capture oscillatory behaviour and possible mitigation measures. To address power system event detection, the second chapter develops a MQTT based framework to detect …

    qu-belfast Repository record for Localization and control of very low-frequency oscillations in Ireland's power system (opens in a new tab) Embargoed until 2029-07-31

  10. Estimating the parameters of a Thévenin equivalent system based on output voltage and current measurements: computational challenges and simulated studies

    … large-scale power system network based on local measurements. The estimation will use a common mathematical method for an overdetermined system. The motivation is taken from phasor measurement unit (PMU) measurements at specific nodes across a transmission line for monitoring purposes. The ac …

    uiuc Repository record for Estimating the parameters of a Thévenin equivalent system based on output voltage and current measurements: computational challenges and simulated studies (opens in a new tab)

  11. Synchronized measurement data conditioning and real-time applications

    <p>Phasor measurement units (PMU), measuring voltage and current phasor with synchronized timestamps, is the fundamental component in wide-area monitoring systems (WAMS) and reveals complex dynamic behaviors of large power systems. The synchronized measurements collected from power grid may degrade …

    utk-theses Repository record for Synchronized measurement data conditioning and real-time applications (opens in a new tab)

  12. Efficient algorithms to expedite transient stability analysis of power systems

    … to expedite the TDS method; iii) integration of PMU measurements into the TSM. Initially, a new adaptive aggregation algorithm for dynamic reduction is proposed, wherein parameters of generators and structure of transmission network are considered to aggregate coherent generators and create a …

    ubc Repository record for Efficient algorithms to expedite transient stability analysis of power systems (opens in a new tab) Download PDF for Efficient algorithms to expedite transient stability analysis of power systems (opens in a new tab)

  13. Data Analytics and Wide-Area Visualization Associated with Power Systems Using Phasor Measurements

    … and visualization of phasor measurement unit (PMU) data obtained from large, interconnected systems. The proposed framework has been implemented in three steps: (a) large-scale, synthetic PMU data generation: conducted to generate research-based measurements with the inclusion of features …

    tamu Repository record for Data Analytics and Wide-Area Visualization Associated with Power Systems Using Phasor Measurements (opens in a new tab)

  14. Power System Online Stability Assessment using Synchrophasor Data Mining

    … and voltage stability from synchrophasor measurements. A regression tree-based approach is proposed to predict the stability margins. Modal analysis and continuation power flow are the tools used to build the knowledge base for off-line DT training. Corresponding metrics include the …

    tamu Repository record for Power System Online Stability Assessment using Synchrophasor Data Mining (opens in a new tab)

  15. Malicious data detection and localization in state estimation leveraging system losses

    … on the network topology information and the measurements from a set of sensors within the network. The state estimates must be accurate even with the presence of corrupted measurements. Traditional techniques used to detect and identify bad sensor measurements in state estimation cannot …

    uiuc Repository record for Malicious data detection and localization in state estimation leveraging system losses (opens in a new tab)

  16. Phasor Measurement Unit Data-Based Steady State and Dynamic Model Estimation

    Phasor measurement units (PMUs) have been put into power grid for real-time monitoring. This research investigates the PMU data for steady state estimation and dynamic model estimation. It focuses on three main research areas to enhance the security of the power system monitoring. First, optimal …

    usf Repository record for Phasor Measurement Unit Data-Based Steady State and Dynamic Model Estimation (opens in a new tab)

  17. Multi-area power system state estimation utilizing boundary measurements and phasor measurement units ( PMUs)

    … Then the thesis shows how conventional measurements and newer, more accurate PMU measurements work within the framework of weighted least squares estimation. Next, the multi-area state estimator is examined closely and the additional measurements provided by PMUs are used to increase …

    tamu Repository record for Multi-area power system state estimation utilizing boundary measurements and phasor measurement units ( PMUs) (opens in a new tab)

  18. Three-Phase Linear State Estimation with Phasor Measurements

    Given the ability of the Phasor Measurement Unit (PMU) to directly measure the system state and the increasing implementation of PMUs across the electric power industry, a natural expansion of state estimation techniques would be one that employed the exclusive use of PMU data. Dominion Virginia …

    vt Repository record for Three-Phase Linear State Estimation with Phasor Measurements (opens in a new tab)

  19. Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks

    … System (WAMS) and Phasor Measurement Unit (PMU), various fault location algorithms have been proposed. The purpose of this work is to determine, modify and test the most appropriate fault location method which can be implemented with a PMU only linear state estimator. The thesis reviews …

    vt Repository record for Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks (opens in a new tab)

  20. Towards Automated Machine Learning on Imperfect Data for Situational Awareness in Power System

    … of sensors (e.g., phasor measurement units (PMUs) and smart meters) and the emerging smart Internet of Things (IoT) sensing devices in the electric grid, large amounts of data are being collected, which provide golden opportunities to achieve high level of situational awareness for reliable …

    unr Repository record for Towards Automated Machine Learning on Imperfect Data for Situational Awareness in Power System (opens in a new tab)

Page 1 of 3