Results 1 to 20 of 277 for “"PMUs"”

  1. Microgrid control and stability improvement using phasor measurement units (PMUs)

    … distribution-level phasor measurement units (D-PMUs) to develop novel control solutions that can overcome current issues that limit the realization of microgrids full potential. For this, first, a new controller focused on harnessing islanded microgrids independent frequency regulation to …

    ubc Repository record for Microgrid control and stability improvement using phasor measurement units (PMUs) (opens in a new tab)

  2. Optimização da Localização e Comunicações de PMUs em Redes de Energia Eléctrica

    A utilização de Phasor Measurement Units (PMUs) permite conhecer a qualidade da energia eléctrica numa determinada área da rede. Estes dispositivos permitem antecipar potenciais falhas, através da medição de magnitudes e ângulos da tensão e da corrente em pontos chave da rede, assim como perceber …

    coimbro Repository record for Optimização da Localização e Comunicações de PMUs em Redes de Energia Eléctrica (opens in a new tab)

  3. Distributed state estimation using phasor measurement units (PMUs)for a system snapshot

    … with advancement in technologies, including PMUs, most of these advances have remained localized with individual utility state estimation. There is an opportunity to establish a coordinated SE approach integration using PMU data across a system, including multiple utilities and this is using …

    ksu Repository record for Distributed state estimation using phasor measurement units (PMUs)for a system snapshot (opens in a new tab)

  4. Coordinated operations of distributed wind generation in a distribution system using PMUs

    … The data which is obtained from these PMUs can be used to calculate the amount of distributed generation and storage that can be dispatched locally at the distribution feeder, thus resulting in a reduction in the peak load levels associated with the distribution feeder as seen by the …

    ksu Repository record for Coordinated operations of distributed wind generation in a distribution system using PMUs (opens in a new tab)

  5. Performance of project management units (PMUS): the case of Sarah Baartman District Municipality

    … the establishment of Project Management Units (PMUs) tasked with administering the MIG funds and managing the infrastructure projects effectively. Whilst MIG’s overall key principles were clearly defined in the MIG policy framework, the attainment of project success has proved elusive for most …

    nmmu Repository record for Performance of project management units (PMUS): the case of Sarah Baartman District Municipality (opens in a new tab)

  6. Peak-ratio analysis method for enhancement of LOM protection using M class PMUs

    … of Frequency (ROCOF) measurement from M-class PMUs, but the key novelty of the method lies in the fact that it employs a new 'peak-ratio' analysis of the measured ROCOF waveform during any frequency disturbance to determine whether the potentially-islanded element of the network remains …

    strathclyde Repository record for Peak-ratio analysis method for enhancement of LOM protection using M class PMUs (opens in a new tab)

  7. Multi-area power system state estimation utilizing boundary measurements and phasor measurement units ( PMUs)

    … and the additional measurements provided by PMUs are used to increase accuracy and computational efficiency. Finally, the multi-area state estimator is tested for accuracy, its ability to detect bad data, and computation time.

    tamu Repository record for Multi-area power system state estimation utilizing boundary measurements and phasor measurement units ( PMUs) (opens in a new tab)

  8. Estimación del margen de estabilidad de voltaje en sistemas de potencia de baja inercia mediante PMUS

    Debido a la poca periodicidad con que se realizan estudios de estabilidad y los reducidos escenarios que se analizan, se han limitado los alcances de monitoreo de estabilidad de los sistemas eléctricos de potencia (SEP). Además, la introducción masiva de energías renovables no convencionales (ERNC) …

    chile Repository record for Estimación del margen de estabilidad de voltaje en sistemas de potencia de baja inercia mediante PMUS (opens in a new tab)

  9. Power-System State Estimation based on PMUs : Static and Dynamic Approaches - from Theory to Real Implementation

    An increasing number of phasor measurement units (PMUs) are being deployed in power systems in order to enhance the situational awareness and, in the near future, we expect that many networks will be extensively equipped with PMUs. These devices provide accurate and synchronized voltage/current …

    epfl Repository record for Power-System State Estimation based on PMUs : Static and Dynamic Approaches - from Theory to Real Implementation (opens in a new tab)

  10. PHASOR MEASUREMENT UNIT DEPLOYMENT APPROACH FOR MAXIMUM OBSERVABILITY CONSIDERING VULNERABILITY ANALYSIS

    … measurements like Phasor Measurement Units (PMUs) Power systems are now being gradually populated by PMU since they provide significant phasor information for the protection and control of power systems during normal and abnormal situations. There are several applications of PMUs, out of …

    clemson Repository record for PHASOR MEASUREMENT UNIT DEPLOYMENT APPROACH FOR MAXIMUM OBSERVABILITY CONSIDERING VULNERABILITY ANALYSIS (opens in a new tab)

  11. Steady State Testing and Analysis of a Phasor Measurement Unit

    Phasor Measurement Units (PMUs) have been instrumental in building a reliable and robust Power System. Recent blackouts have increased the importance of PMUs and PMUs from various manufacturers are being installed in the in large quantities in the North American Grid. The interoperability and …

    vt Repository record for Steady State Testing and Analysis of a Phasor Measurement Unit (opens in a new tab)

  12. Optimization and Heuristic Facility Location Algorithms for the Smart Grid

    … can be achieved by Phasor Measurement Units (PMUs). Despite having a number of advantages, PMUs are expensive and cannot be placed at every node in a network for constant observation. Therefore, it is economically feasible to place these PMUs at optimal locations, depending on the demand of …

    ndsu Repository record for Optimization and Heuristic Facility Location Algorithms for the Smart Grid (opens in a new tab)

  13. Placement of phasor measurement units : optimization approaches and applications

    "Phasor measurement units (PMUs) provide measurements with high precision at a high resolution (up to 50 samples per second). These measurements are synchronized and time-stamped using the Global Positioning System. Despite these advantages, the industry has been slow in adopting PMU technology due …

    msu Repository record for Placement of phasor measurement units : optimization approaches and applications (opens in a new tab)

  14. Robust GPS-based timing for phasor measurement units based on single-receiver and multi-receiver position-information-aided vector tracking

    … industry to utilize phasor measurement units (PMUs) for wide area monitoring and control. PMUs are considered to be one of the most critical technologies for the future and modernization of the power grid. This technology produces time-stamped voltage and current phasor measurements, allowing …

    uiuc Repository record for Robust GPS-based timing for phasor measurement units based on single-receiver and multi-receiver position-information-aided vector tracking (opens in a new tab)

  15. On the Power Domination Problem in Graphs

    … accomplished by placing phase measurement units (PMUs) at selected network locations. However, due to the high cost of the PMUs, their number must be minimized [1]. Finding the minimum number of PMUs needed to monitor a given power network, as well as to determine the locations where the PMUs …

    texas-state Repository record for On the Power Domination Problem in Graphs (opens in a new tab)

  16. The Virginia Tech Calibration System

    … relies on the consistent measurements of PMUs across the system. This has become a major challenge for designers since large networks use PMUs from various manufacturers who likely implement different synchrophasor technologies to perform the phasor estimations. The current synchrophasor …

    vt Repository record for The Virginia Tech Calibration System (opens in a new tab)

  17. Development and application of synchronized wide-area power grid measurement

    <p>Phasor measurement units (PMUs) provide an innovative technology for real-time monitoring of the operational state of entire power systems and significantly improve power grid dynamic observability. This dissertation focuses on development and application of synchronized power grid measurements. …

    utk-theses Repository record for Development and application of synchronized wide-area power grid measurement (opens in a new tab)

  18. Development of a Low-cost Phasor Measurement Unit

    … such as real-time and synchronize measurements. PMUs have many applications from gird protection to grid control, the down side however is that commercial PMUs have a high price tag staring at $2,400 and can go up to $10,000 USD. This large price can make it difficult to install a large number of …

    ttu Repository record for Development of a Low-cost Phasor Measurement Unit (opens in a new tab)

  19. Phasor Measurement Units Applications Prioritization Based on Wide-Area Disturbance Events

    Synchrophasor Measurement Units (PMUs) are devices that can not only measure but also time stamp voltage, current, frequency, among others. PMUs take these synchronized measurements as fast as 60 times per second; compared with the traditional 2-4 second SCADA measurements, PMUs bring a much clear …

    vt Repository record for Phasor Measurement Units Applications Prioritization Based on Wide-Area Disturbance Events (opens in a new tab)

  20. Transient Stability Prediction based on Synchronized Phasor Measurements and Controlled Islanding

    … With the advent of Phasor Measurement Units (PMUs) in power systems, it is now possible to monitor the behavior of the system in real time and provide important information for transient stability assessment and enhancement. Techniques such as the rotor oscillation prediction method based on …

    vt Repository record for Transient Stability Prediction based on Synchronized Phasor Measurements and Controlled Islanding (opens in a new tab)