Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"POROUS COATED"”.
-
A three-dimensional finite element stress analysis of interface conditions in porous coated hip prosthesis
… bone/implant interface for various amounts of porous coating and different stem materials. The finite element model consists of 909 nodes comprising 536 linear eight-node solid brick elements and 176 two-node interface elements. The finite element analysis code employed is SUPERTAB from SDRC. …
-
Pool boiling heat transfer from porous-coated surfaces in FC-72, the effects of subcooling and non-boiling immersion time
Thesis (M.S.)--Michigan State University. Department of Mechanical Engineering, 2005
-
Nucleate pool-boiling of R-114 refrigerant and oil mixtures from water-heated enhanced surfaces
… a spirally roped copper-nickel tube with a porous coating; and a copper tube with a structured outer surface and a multiple-start helical ridged inner surface. Measurements were made for refrigerant-oil mixtures at oil concentrations from 0 to 6 mass percent with a boiling pool temperature …
-
The Effect of Porous Poly-L-Lactic Acid Coatings on Tissue Response and Subsequent Glucose Sensor Performance
… leached with ammonium bicarbonate to produce porous coatings for Medtronic MiniMed SOF–sensor glucose sensors. Coating properties included 30μm pore diameters, 90% porosity, and 50μm wall thickness. Cytotoxicity, degradation, and sensor response time studies were performed to ensure the porous …
-
Three dimensional finite element analysis of a tibial ankle prosthesis
… used to evaluate and compare partially and fully porous coated tibial components, of an ankle prosthesis, implanted in the distal tibia. The geometry of the distal tibia is determined from measurements of cross sections of a human tibia. From the measurements, solid models of the cancellous and …
-
Η ΟΛΙΚΗ ΑΡΘΡΟΠΛΑΣΤΙΚΗ ΤΟΥ ΓΟΝΑΤΟΣ ΜΕ ΕΝΔΟΠΡΟΘΕΣΗ PORUS COATED ANATOMIC
… IDIOPATHIC OSTEONECROSES (2). WE HAVE PUT THE POROUS COATED ANATOMIC TOTAL KNEE ENDOPROSTHESES. 23 ARTHROPLASTIES HAVE BEEN DONE UNCEMENTED AND 2 CEMENTED. THE EARLY FIXATION BY TIGHT FITTING OF THE PROSTHESES ON THE CUTTED BONE ENDS THAT IS FOLLOWED BY TISSUE INGROWTH INTO THE POROUS SURFACE …
-
The Effect of a Medial Collar on the Initial Stability of a Cementless Primary Femoral Hip Prosthesis
… of a triple-tapered, broach-only, proximally porous-coated primary cementless hip prosthesis using a computational analysis. In a computer model, collared and collarless prostheses are placed into six femora from six different patients and subjected to two separate loading conditions …
-
Nucleate pool boiling characteristics of R-124
… a modified finned tube (TURBO-B); and a porous coated tube (HIGH FLUX). The tests were carried out using the procedure used for CFC-114 at the same saturation temperature of 2.2 degrees C. This allowed for direct comparison of the pool boiling heat transfer characteristics between the two …
-
The effect of oil on the onset of nucleate pool boiling of R-124 from a single horizontal tube
… inch low-integral finned (GEWA-K) tubes, and (4) porous-coated (HIGH FLUX) tube. The effect of dissolved gases, subcooling and pressure on the onset of nucleate boiling were also investigated. An oil concentration of 3% tends to delay the onset of nucleate pool boiling (compared to pure R-124) on …
-
Bone regeneration in novel porous titanium implants
… and compare it to a commercially-available porous-coated press-fit dental implant (Endopore, Innova Corp.). Twelve cylindrical shaped implants 3 mm in diameter x 5 mm long were made by EBM (Southern Methodist Univ.) using Ti6Al4V ELI alloy. Twelve commercial implants (Endopore, Innova Corp.) …
-
Spark Plasma Sintering of Titanium and Cobalt Alloys For Biomedical Applications
… parameters for the production of a highly porous (cp-Ti), full density materials (Ti-6Al-4V and Co-28Cr-6Mo), and their combination in a surface functionalized full density substrate was the central focus. The SPS parameters were optimized to obtain the Co-28Cr-6Mo alloy in full density …
-
Computer aided stress analysis of the femur with prosthetic hip stem utilizing computed tomography
… or titanium alloy prosthesis, also cemented or porous-coated prosthesis are studied. A comparison of the stress patterns for the three different femora is made and a radiographic follow-up study in two cases is carried out at 14 months and 12 months postoperation for analyzing the bone …
-
Improving Indwelling Glucose Sensor Performance: Porous, Dexamethasone-Releasing Coatings that Modulate the Foreign Body Response
… </p><p>First, Dex-releasing polyurethane porous coatings of controlled pore size and thickness were fabricated using salt-leaching/gas-foaming technique. Porosity, pore size, thickness, drug release kinetics, drug loading amount, and drug bioactivity were evaluated. In vitro sensor …
-
Η ΕΝΔΟΠΡΟΘΕΣΗ AML (ANATOMIC MEDULLARY LOCKING) ΣΤΗΝ ΑΝΤΙΜΕΤΩΠΙΣΗ ΤΗΣ ΟΣΤΕΟΑΡΘΡΙΤΙΔΑΣ ΤΟΥ ΙΣΧΙΟΥ
FROM OCTOBER 1993 TO OCTOBER 1996 IN THE ORTHOPAEDIC DEPARTMENT OF THE UNIVERSITY HOSPITAL OF IOANNINA, 82 PATIENTS (89 HIPS) WERE OPERATED UPON FOR OSTEOARTHRITIS OF THE HIP WITH THE AML (ANATOMIC MEDULLARY LOCKING) TOTAL HIP ENDOPROSTHESIS. 7 PATIENTS HAD THE SAME OPERATION IN BOTH HIPS. THE MEAN …