  1. A Portal imager-based patient dosimetry system

    … therapy (IMRT) has been developed. An electronic portal image, calibrated in terms of absolute dose, is acquired for each radiation field following transmission through the patient at the time of treatment. For an IMRT field, the portal image signal is back-projected through a model of the patient …

    uvic Repository record for A Portal imager-based patient dosimetry system (opens in a new tab)

  2. The Use of an On-Board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy.

    … in this field is the repurposing of the portal imager to not only be used for tumor localization but for recording dose distributions as well. Several advantages make portal imagers attractive options for this purpose. Very high spatial resolution allows for better verification of small …

    ohiolink Repository record for The Use of an On-Board MV Imager for Plan Verification of Intensity Modulated Radiation Therapy and Volumetrically Modulated Arc Therapy. (opens in a new tab)

  3. Transmission dosimetry with a scanning liquid filled electronic portal imaging device for megavoltage photo beams

    … to the success of radiation therapy. The use of portal imaging in radiotherapy for verification of field size, shape, orientation and patient setup is of vital importance in delivering successful radiation treatment. One of the modalities used in improving tumor localization and geometric …

    ubc Repository record for Transmission dosimetry with a scanning liquid filled electronic portal imaging device for megavoltage photo beams (opens in a new tab)

  4. Comparison of video and CCD cameras in online portal imagers calibrated for dosimetry

    Video-based electronic portal imaging devices (EPIDs) are the most common type of portal imager found in clinical practice. In addition to providing a method to detect and correct patient set-up errors and record treatments, possibilities exist for the dosimetric use of video-based EPIDs. To …

    manitoba Repository record for Comparison of video and CCD cameras in online portal imagers calibrated for dosimetry (opens in a new tab)

  5. Kilovoltage Intensity Modulated Radiotherapy

    … The MRC was mounted between a decommissioned portal imager and several phantoms loaded with radiochromic film. Plans were created and delivered, and the resulting films were analyzed. Film results were examined for dose falloff and, for the Rando phantom, enhancement due to the presence of …

    wayne-thes Repository record for Kilovoltage Intensity Modulated Radiotherapy (opens in a new tab)

  6. Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms

    Electronic portal imagers designed and used to verify the positioning of a cancer patient undergoing radiation treatment can also be employed to measure the in vivo dose received by the patient. This thesis investigates the ratio of the dose from patient-scattered particles to the dose from primary …

    ubc Repository record for Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms (opens in a new tab)

  7. Quality Assurance Procedures Implementation for Varian TrueBeam

    … of freedom (DOF) couch, RapidArc, kV on board imager, MV portal imager and Cone Beam CT (CBCT) imaging. This system allows the clinical delivery of modern image guided radiation therapy (IGRT) modalities such as IMRT/VMAT, and SRS/SRT/SBRT. The periodic quality assurance (QA) tests of these …

    unlv Repository record for Quality Assurance Procedures Implementation for Varian TrueBeam (opens in a new tab)