Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 4 of 4 for “"PRO-FM"”

  1. Applications of FM Noise Radar Waveforms: Spatial Modulation and Polarization Diversity

    … the exploitation of highdimensional nonrecurrent FM-noise waveforms. The first involving a simultaneous dual-polarized emission scheme that provides good separability with respect to co- and cross-polarized terms and the second mimicking the passive actuation of the human eye with a MIMO emission. …

    ku Repository record for Applications of FM Noise Radar Waveforms: Spatial Modulation and Polarization Diversity (opens in a new tab)

  2. Expanding the Doppler Span of Fast-Time Sidelobe Suppression for Random FM Waveforms

    Numerous random FM (RFM) waveform design techniques have been developed and shown to provide good spectral containment and low autocorrelation sidelobes, as compared to unoptimized RFM waveforms whose autocorrelation sidelobes depend on time-bandwidth (TB) product alone. However, these design …

    ku Repository record for Expanding the Doppler Span of Fast-Time Sidelobe Suppression for Random FM Waveforms (opens in a new tab)

  3. Multi-Objective Optimization of FM Noise Waveforms via Generalized Frequency Template Error Metrics

    FM noise waveforms have been experimentally demonstrated to achieve high time bandwidth products and low autocorrelation sidelobes while achieving acceptable spectral containment in physical implementation. Still, it may be necessary to further reduce sidelobe levels for detection or improve …

    ku Repository record for Multi-Objective Optimization of FM Noise Waveforms via Generalized Frequency Template Error Metrics (opens in a new tab)

  4. Validity and Reliability of the Medical Graphics VO2000, Cosmed Fitmate Pro, and HealtheTech MedGem During Rest and at Submaximal and Maximal Exercise Intensities

    … reliability and validity of the Cosmed Fitmate Pro (FM) and the Medical Graphics VO2000 against the ParvoMedics Turemax 2400 (TM) computerized metabolic system in the measurement of VO2, VE, and F EO2 during sub-maximal and maximal exercise intensities. In addition, to assess the reliability and …

    sdstate Repository record for Validity and Reliability of the Medical Graphics VO2000, Cosmed Fitmate Pro, and HealtheTech MedGem During Rest and at Submaximal and Maximal Exercise Intensities (opens in a new tab)