Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 66 for “"PSEUDO-CONTINUOUS"”

  1. Sequence Optimization in Pseudo-Continuous Arterial Spin Labeling

    … do tratamento de doenças do cérebro. Pseudo-continuous ASL (pCASL) é o método de implementação recomendado para estudos ASL, uma vez que combina as vantagens de métodos anteriores, uma elevada relação sinal-ruído (S/N) e eficiência de inversão. O objetivo deste trabalho consiste na …

    coimbro Repository record for Sequence Optimization in Pseudo-Continuous Arterial Spin Labeling (opens in a new tab)

  2. Pseudo-continuous spatial and spatio-temporal modelling of disease risk

    … study aims to address this problem by creating a pseudo continuous disease risk surface over the Greater Glasgow and Clyde Health Board. A set of regular grid squares is overlaid across the study region and the main focus of this study is to estimate disease risk in each grid square after removing …

    glasgow Repository record for Pseudo-continuous spatial and spatio-temporal modelling of disease risk (opens in a new tab)

  3. Assessment of Pseudo-Continuous Arterial Spin Labeling (pCASL) Inter-Session Reliability in the Quantification of Cerebral Perfusion

    … used a variation of the ASL technique known as pseudo-continuous ASL (pCASL). This form of ASL is the clinical standard (Alsop et al., 2015). However, it is not well documented the that pCASL is reliable between sessions spanning days to weeks. In this study, we assessed the inter-session …

    ohiolink Repository record for Assessment of Pseudo-Continuous Arterial Spin Labeling (pCASL) Inter-Session Reliability in the Quantification of Cerebral Perfusion (opens in a new tab)

  4. Toward Measuring a Charge-Parity Violating Electric Dipole Moment of the Electron: Production and Pseudo-Continuous Resonance Enhanced Multiphoton Ionization of

    Over one half century has passed since the possible violation of time reversal symmetry was proposed by Purcell and Ramsey. The Standard Model predicts that a value of the e-EDM |de,SM|<10-38e &middot cm that is beyond the reach of current experiment. At the same time, theories beyond the Standard …

    oklahoma-thes Repository record for Toward Measuring a Charge-Parity Violating Electric Dipole Moment of the Electron: Production and Pseudo-Continuous Resonance Enhanced Multiphoton Ionization of (opens in a new tab)

  5. Ultrasonic Technique for the Measurement of Stress in Bolts

    An ultrasonic bolt monitor based on the pseudo-continuous-wave principle has been designed and fabricated. This ultrasonic bolt monitor uses carrier phase detection to track the frequency of mechanical resonance of the bolt. In this thesis we have discussed theory and principle of this ultrasonic …

    marquette Repository record for Ultrasonic Technique for the Measurement of Stress in Bolts (opens in a new tab)

  6. Follow your label: simultanous 4D angiography and perfusion imaging by arterial spin labeling MRI

    … arterial spin labeling (ASL) MRI. Time-encoded pseudo-continuous (ASL) preparation was combined with multiple different readout modules, such as Look-Locker, Simultaneous multi-slice acquisition or a golden angle based non-Cartesian k-space trajectory to obtain high temporal resolution …

    leiden Repository record for Follow your label: simultanous 4D angiography and perfusion imaging by arterial spin labeling MRI (opens in a new tab)

  7. Arterial spin labeling in space and time : new MRI sequences to probe cerebral hemodynamics

    … selective ASL (AccASL) was compared with pseudo continuous ASL (pCASL), a traditional ASL method, as well as other spatially non-selective ASL methods (velocity selective ASL, as introduced by Wong et al with two velocity-selective blocks, and using only a single labeling module), and with …

    leiden Repository record for Arterial spin labeling in space and time : new MRI sequences to probe cerebral hemodynamics (opens in a new tab)

  8. An interference-cancellation receiver for multi-band and multi-standard wireless communication systems

    … filter has programmable gain and pseudo-continuous bandwidth, which reduce the total power consumption and silicon area of the receiver. The measured result of a prototype silicon chip shows the effectiveness of the technique. With these two topologies, a multi-band multi-standard …

    gatech Repository record for An interference-cancellation receiver for multi-band and multi-standard wireless communication systems (opens in a new tab)

  9. Applications pré-cliniques de l'IRM de perfusion

    … d'un marquage de type unbalanced-pCASL (pseudo-Continuous ASL). Ces travaux de thèse ont pour objectif la mise en place, le test et la validation de la séquence pCASL sur un IRM préclinique 7T et l'utilisation de cette méthode pour l'étude des changements de perfusion cérébrale en cas …

    star-france Repository record for Applications pré-cliniques de l'IRM de perfusion (opens in a new tab)

  10. From the macro- to the microvasculature : temporal and spatial visualization using arterial spin labeling

    … on ASL techniques, which include pulsed ASL, pseudo-continuous ASL (pCASL), vessel-encoded pCASL, time-encoded pCASL as well as simultaneous multi-slice pCASL. The underlying motivation of these development is to reduce the burden on patients by employing non-invasive ASL techniques as …

    leiden Repository record for From the macro- to the microvasculature : temporal and spatial visualization using arterial spin labeling (opens in a new tab)

  11. Bio-hydrogen and biomass-supported palladium catalyst for energy production and waste-minimisation

    … biological H2 production in a sustainable way. Pseudo-continuous H2 production was achieved with improved efficiency, via the bacterial fermentation of sugars in a dual-bioreactor (‘upstream system’) comprising a dark fermentation coupled to a photofermentation. Excess biomass from the upstream …

    birmingham Repository record for Bio-hydrogen and biomass-supported palladium catalyst for energy production and waste-minimisation (opens in a new tab)

  12. Quantile regression for count data with optimized jittering

    … It models the conditional quantiles of the continuous response variable instead of modeling the conditional mean. Often times we encounter discrete response variables, such as counts or other kind of categorical variables. Due to the discontinuity of counts, traditional QR creates systematic …

    newfoundland Repository record for Quantile regression for count data with optimized jittering (opens in a new tab)

  13. Resting Perfusion Alterations in Veterans and First Responders with PTSD Following an Open-label eTMS Study

    … was assessed preceding and following eTMS with pseudo-continuous arterial spin labeling (pCASL) MRI. Resting perfusion significantly increased across several regions, most notably in the hippocampus and amygdala. The increased perfusion in the left hippocampus and amygdala significantly …

    ohiolink Repository record for Resting Perfusion Alterations in Veterans and First Responders with PTSD Following an Open-label eTMS Study (opens in a new tab)

  14. Freewheel duration optimization schemes for integrated single-inductor multiple-output switching converters

    … switching converter. The SIDO converter works in pseudo-continuous conduction mode to enhance its driving capability. The single-charge successive-discharge scheme is also adopted to increase the flexibility of output loading ratio between outputs and reduces switching loss. A gate triggering cell …

    hkust Repository record for Freewheel duration optimization schemes for integrated single-inductor multiple-output switching converters (opens in a new tab)

  15. Integrated charge-control single-inductor dual-output switching converters

    … are presented. These converters work in pseudo-continuous conduction mode (PCCM) in achieving a larger current handling capability than DCM (discontinuous conduction mode) converters while retaining a low cross-regulation. By monitoring the charges delivered to the two loads directly, …

    hkust Repository record for Integrated charge-control single-inductor dual-output switching converters (opens in a new tab)

  16. Arterial spin labelling in neurocognitive and other mental disorders: a systematic review

    … guidelines for the clinical application of pseudo-continuous arterial spin labelling (pCASL). The included studies comprised samples of patients with neurocognitive disorders (NCD), including Alzheimer's disease (AD), mild cognitive impairment (MCI), frontotemporal lobar degeneration (FTLD), …

    porto Repository record for Arterial spin labelling in neurocognitive and other mental disorders: a systematic review (opens in a new tab)

  17. Shape Memory Alloy-based Whole Blood Glucose Monitoring Device: The e-Mosquito

    … for minimally invasive, autonomous and pseudo-continuous blood glucose monitoring, the e-Mosquito. The proposed design of the e-Mosquito device aims to extract whole blood sample from a small lanced skin wound using a novel shape memory alloy (SMA)-based microactuator and directly …

    calgary Repository record for Shape Memory Alloy-based Whole Blood Glucose Monitoring Device: The e-Mosquito (opens in a new tab)

  18. Application of center-out k-space trajectories to three-dimensional imaging of structure and blood transport in the human brain

    … which was later used in the combination of pseudo-continuous arterial spin labeling module in order to track a short arterial spin labeling (ASL) bolus of well-defined length along the fast passage through the large vessel compartment of the brain. Parametric maps of ASL signal change, …

    qucosa-diss Repository record for Application of center-out k-space trajectories to three-dimensional imaging of structure and blood transport in the human brain (opens in a new tab)

  19. Detection of endogenous compounds in body fluids

    … pulsed KrF laser operating at 248 nm in a pseudo-continuous wave mode was evaluated as an excitation source for native fluorescence detection of tryptophan. On-column LINF detection limits in the low nanomolar range are obtained for tryptophan with the KrF source, which is similar to that …

    concordia

Page 1 of 4