Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"PTR-ToF-MS"”.

  1. Online volatilomics of food fermentation by PTR-ToF-MS for sustainable bioprocess innovation

    … Reaction Time-of-Flight Mass Spectrometry (PTR-ToF-MS) as a fast, direct, and highly sensitive platform for monitoring VOCs in food fermentation processes in real-time. VOCs are more than simple microbial metabolism by-products; they serve as valuable markers for understanding microbial …

    trento Repository record for Online volatilomics of food fermentation by PTR-ToF-MS for sustainable bioprocess innovation (opens in a new tab) Embargoed

  2. Optimization of volatile organic compound sensitivity of Vocus PTR-ToF-MS for quantifying disinfection byproducts

    … have led to the release of the Vocus 2R PTR-ToF, which offers real-time measurements of over 1500 compounds. The Vocus 2R PTR-ToF mass spectrometer offers world-leading sensitivity and mass resolution for the detection of VOCs in multiple ionization modes, but to maximize its capabilities …

    texas Repository record for Optimization of volatile organic compound sensitivity of Vocus PTR-ToF-MS for quantifying disinfection byproducts (opens in a new tab)

  3. Detekce vonných látek v bylinách

    … protónovou ionizáciou a analyzátorom doby letu (PTR-TOF-MS), a tandemovej techniky plynovej chromatografie s hmotnostnou spektrometriou (GC/MS). Pomocou PTR-TOF-MS boli vybrané vonné látky s výraznejším signálom, ktoré boli ďalej rozoberané a identifikované pomocou GC/MS. Monoterpeny tvorili …

    brno-tech Repository record for Detekce vonných látek v bylinách (opens in a new tab)

  4. Chemometric analysis of full scan direct mass spectrometry data for the discrimination and source apportionment of atmospheric volatile organic compounds measured from a moving vehicle.

    … more common place. Direct mass spectrometry (MS), such as membrane introduction mass spectrometry (MIMS) and proton-transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) facilitate real-time, continuous measurements of VOCs in air, with full scan mass spectral data capturing changes …

    uvic Repository record for Chemometric analysis of full scan direct mass spectrometry data for the discrimination and source apportionment of atmospheric volatile organic compounds measured from a moving vehicle. (opens in a new tab)

  5. Rapid and Green Volatilomics of Roasted Hazelnuts: Comparative Multiplatform Analysis and Advanced Data Mining

    … coupled with Mass Spectrometry (GC-MS) remains the reference technique, reducing analysis time and minimizing the environmental impact of analytical methods are becoming pressing priorities, especially in industrial contexts. The aim of this thesis was to evaluate the potential of …

    trento Repository record for Rapid and Green Volatilomics of Roasted Hazelnuts: Comparative Multiplatform Analysis and Advanced Data Mining (opens in a new tab) Embargoed

  6. Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures

    … reaction time-of-flight mass spectrometer (PTR-ToF-MS), we can improve risk assessment through comprehensive characterization of VOC mixtures in distinct settings. Mobile air sampling is an up-and-coming method for air sampling; the high spatial and temporal resolution affords the …

    tamu Repository record for Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures (opens in a new tab) Embargoed until 2027-08-01

  7. Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures

    … reaction time-of-flight mass spectrometer (PTR-ToF-MS), we can improve risk assessment through comprehensive characterization of VOC mixtures in distinct settings. Mobile air sampling is an up-and-coming method for air sampling; the high spatial and temporal resolution affords the …

    tamu Repository record for Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures (opens in a new tab) Embargoed until 2027-08-01

  8. Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures

    … reaction time-of-flight mass spectrometer (PTR-ToF-MS), we can improve risk assessment through comprehensive characterization of VOC mixtures in distinct settings. Mobile air sampling is an up-and-coming method for air sampling; the high spatial and temporal resolution affords the …

    tamu Repository record for Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures (opens in a new tab) Embargoed until 2027-08-01

  9. Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures

    … reaction time-of-flight mass spectrometer (PTR-ToF-MS), we can improve risk assessment through comprehensive characterization of VOC mixtures in distinct settings. Mobile air sampling is an up-and-coming method for air sampling; the high spatial and temporal resolution affords the …

    tamu Repository record for Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures (opens in a new tab) Embargoed until 2027-08-01

  10. Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures

    … reaction time-of-flight mass spectrometer (PTR-ToF-MS), we can improve risk assessment through comprehensive characterization of VOC mixtures in distinct settings. Mobile air sampling is an up-and-coming method for air sampling; the high spatial and temporal resolution affords the …

    tamu Repository record for Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures (opens in a new tab) Embargoed until 2027-08-01

  11. Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures

    … reaction time-of-flight mass spectrometer (PTR-ToF-MS), we can improve risk assessment through comprehensive characterization of VOC mixtures in distinct settings. Mobile air sampling is an up-and-coming method for air sampling; the high spatial and temporal resolution affords the …

    tamu Repository record for Application of Mobile Air Monitoring in Diverse Environments to Characterize Hazardous Volatile Organic Compound Mixtures (opens in a new tab) Embargoed until 2027-08-01

  12. Chamber studies of glyoxal yields from the oxidation of selected biogenic VOCs

    … Reaction-Time of Flight-Mass Spectrometer (PTR-ToF-MS), a glyoxal laser-induced-phosphorescence (GLYOX-LIP) instrument, and a Fluorescence Assay by Gas Expansion (FAGE) instrument. Simultaneous measurement with these instruments during oxidation reactions allowed detection of hydroxyl (OH) …

    whiterose Download PDF for Chamber studies of glyoxal yields from the oxidation of selected biogenic VOCs (opens in a new tab)

  13. INVESTIGATION OF EMISSIONS AND CHEMISTRY OF FORMIC ACID AND ACETIC ACID IN WILDFIRE SMOKE

    … chemical ionization mass spectrometer (HRToF-CIMS) on average are approximately 1.48 times higher than the proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS) for HCOOH, and 1.36 times higher for emission passes. Secondly, I examined emissions of HCOOH and CH3COOH …

    montana Repository record for INVESTIGATION OF EMISSIONS AND CHEMISTRY OF FORMIC ACID AND ACETIC ACID IN WILDFIRE SMOKE (opens in a new tab)

  14. INVESTIGATION OF EMISSIONS AND CHEMISTRY OF FORMIC ACID AND ACETIC ACID IN WILDFIRE SMOKE

    … chemical ionization mass spectrometer (HRToF-CIMS) on average are approximately 1.48 times higher than the proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS) for HCOOH, and 1.36 times higher for emission passes. Secondly, I examined emissions of HCOOH and CH3COOH …

    montana-tech Repository record for INVESTIGATION OF EMISSIONS AND CHEMISTRY OF FORMIC ACID AND ACETIC ACID IN WILDFIRE SMOKE (opens in a new tab)

  15. ADVANCED MEASUREMENTS OF UNDERSAMPLED GLOBALLY SIGNIFICANT BIOMASS BURNING SOURCES

    … time-of-flight mass spectrometer (PTR-TOF-MS) to characterize biomass burning (BB) emissions for the first time. BB is the second largest global atmospheric source of gas-phase non-methane organic compounds (NMOCs) and a significant portion of the higher molecular weight species …

    montana-tech Repository record for ADVANCED MEASUREMENTS OF UNDERSAMPLED GLOBALLY SIGNIFICANT BIOMASS BURNING SOURCES (opens in a new tab)

  16. ADVANCED MEASUREMENTS OF UNDERSAMPLED GLOBALLY SIGNIFICANT BIOMASS BURNING SOURCES

    … time-of-flight mass spectrometer (PTR-TOF-MS) to characterize biomass burning (BB) emissions for the first time. BB is the second largest global atmospheric source of gas-phase non-methane organic compounds (NMOCs) and a significant portion of the higher molecular weight species …

    montana Repository record for ADVANCED MEASUREMENTS OF UNDERSAMPLED GLOBALLY SIGNIFICANT BIOMASS BURNING SOURCES (opens in a new tab)

  17. Studium chemických procesů iniciovaných elektrickým výbojem v atmosféře podobné Titanu ve stacionárním režimu

    … hmotnostní spektrometrie s protonovou ionizací (PTR-ToF-MS). Detekovány byly především jednoduché dusíkaté alifatické uhlovodíky, avšak se zvyšujícím se průtokem CH4 docházelo ke vzniku složitějších aromatických uhlovodíků v případě obou výbojů. Složení plazmatu a jeho diagnostika byla zkoumána …

    brno-tech Repository record for Studium chemických procesů iniciovaných elektrickým výbojem v atmosféře podobné Titanu ve stacionárním režimu (opens in a new tab)

  18. Analýza produktů elektrického výboje ve směsích vody a etanolu

    … a acetaldehyd. Na sběr dat byla použita metoda PTR-TOF-MS. Tato metoda je vhodná díky rychlé odezvě a okamžitému měření, pro naše potřeby poskytuje dostatečně přesné výsledky. Pro lepší a přesnější stanovení je do budoucna vhodné použít kombinaci s nějakou chromatografickou metodou – např. …

    brno-tech Repository record for Analýza produktů elektrického výboje ve směsích vody a etanolu (opens in a new tab)

  19. Optimizing instrument signal to quantify urban volatile compound concentrations and emission sources

    … of chemical ionization mass spectrometry (CIMS), I measured a constant concentration of a 14-compound gas standard tank with a Vocus proton transfer reaction time-of-flight mass spectrometry (Vocus PTR-ToF-MS) in both H₃O⁺ and NH₄⁺ ionization modes and automatically varied voltage and …

    texas Repository record for Optimizing instrument signal to quantify urban volatile compound concentrations and emission sources (opens in a new tab)

  20. Application of Proton Transfer Reaction Mass Spectrometry to Analytical Science

    … reaction time-of-flight mass spectrometer, PTR-TOF-MS, a bespoke model manufactured by Kore Technology Ltd. for Smiths Detection. This instrument achieves 'soft' ionization of volatile organic compounds (VOCs) by proton transfer from protonated water vapour in a reaction chamber at 1 mbar (= …

    the-open-u Download PDF for Application of Proton Transfer Reaction Mass Spectrometry to Analytical Science (opens in a new tab)

Page 1 of 2