Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 366 for “"Palpation"”.

  1. Obstetrical palpation: the art of palpation applied to the diagnosis of obstetrical conditions

    … articles upon it. The value of Obstetrical Palpation was first recognised by the Germans and Austrians who practise the art extensively. The French learned it from them and now it is extensively employed throughout Paris and all France. It is also practised in Belgium, where it was …

    edinburgh Repository record for Obstetrical palpation: the art of palpation applied to the diagnosis of obstetrical conditions (opens in a new tab)

  2. NEUROMORPHIC TACTILE SENSING FOR SOFT TISSUE PALPATION USING A ROBOTIC FINGER

    Palpation is an examination procedure to identify tissue abnormality. Robot-assisted tactile sensing provides robust capabilities for differentiating hard inclusions. In this work, an integrated approach for robotic palpation with a bio-inspired tactile sensing approach is presented to discriminate …

    nus Repository record for NEUROMORPHIC TACTILE SENSING FOR SOFT TISSUE PALPATION USING A ROBOTIC FINGER (opens in a new tab) Download file for NEUROMORPHIC TACTILE SENSING FOR SOFT TISSUE PALPATION USING A ROBOTIC FINGER (opens in a new tab)

  3. Diagnostic Palpation in Osteopathic Medicine: A Putative Neurocognitive Model of Expertise

    … which the development of expertise in diagnostic palpation in osteopathic medicine is associated with changes in cognitive processing. Chapter 2 and Chapter 3 review, respectively, the literature on the role of analytical and non-analytical processing in osteopathic and medical clinical decision …

    oxford-brookes Repository record for Diagnostic Palpation in Osteopathic Medicine: A Putative Neurocognitive Model of Expertise (opens in a new tab) Download PDF for Diagnostic Palpation in Osteopathic Medicine: A Putative Neurocognitive Model of Expertise (opens in a new tab)

  4. A mathematical relationship between palpation forces and displacement associated with restriction

    … data that describes osteopathic clinician palpation forces and displacement. The model delivers an accurate (R[subscript 2] [greater than or equal to] 0.95) representation of forces and displacements. Palpation is the examination of the body by means of the hands and fingers to evaluate the …

    missouri Repository record for A mathematical relationship between palpation forces and displacement associated with restriction (opens in a new tab)

  5. Distinguishing characteristics of thoracic medial paraspinal structures determined as abnormal by palpation

    … the paravertebral gutter (PVG) region by manual palpation has been proposed to be an important diagnostic finding in osteopathic medicine. The pathophysiology of tissues at sites detected as abnormal by palpation and reported as tender by the subject (AbPT) is speculative, because evidence of …

    vu-aus

  6. The accuracy of pregnancy determination by rectal palpation at various post-breeding intervals

    … heat following calving, (2) examining by rectal palpation to determine if any abnormality or problem occurs to prevent pregnancy, (3) breeding cow first heat period after sixty days following calving, and (4) examining by rectal palpation to determine if pregnancy has occurred. It is believed …

    ut-knoxville Repository record for The accuracy of pregnancy determination by rectal palpation at various post-breeding intervals (opens in a new tab)

  7. Development of Robotic Medical Devices: Applications in Tele-palpation, Training, and in Orthognathic Surgery

    … i.e., a soft robotic device applied to tele-palpation and training and a rigid robotic device for orthognathic surgery. We design and develop a novel tactile display apparatus to facilitate medical palpation and enable early diagnosis of a possibly cancerous tumor or thyroid lump. We also …

    ucf Repository record for Development of Robotic Medical Devices: Applications in Tele-palpation, Training, and in Orthognathic Surgery (opens in a new tab)

  8. Abdominal palpation to determine fetal position at the onset of labour: an accuracy study

    Since the late 19th Century, abdominal palpation of the gravid uterus has been routine, worldwide obstetric practice to determine fetal position. A systematic review showed a dearth of research on the accuracy of this ubiquitous test. A test accuracy study was carried out prospectively to assess …

    birmingham Download PDF for Abdominal palpation to determine fetal position at the onset of labour: an accuracy study (opens in a new tab)

  9. HEART RATE RESPONSE TO CAROTID ARTERY PALPATION IN WOMEN AFTER CESSATION OF MODERATE EXERCISE

    … were made prior to, during, and after carotid palpation. Two t-tests for correlated groups were computed. The first t-test compared pre-palpation heart rates with the heart rates during palpation. The second t-test compared the heart rates during palpation with the post-palpation heart rates. …

    ku Repository record for HEART RATE RESPONSE TO CAROTID ARTERY PALPATION IN WOMEN AFTER CESSATION OF MODERATE EXERCISE (opens in a new tab)

  10. State Estimation and Control of Continuum Robots with Applications in Force Sensing and Tissue Palpation

    … intrinsic force sensing for surgical robotic palpation. Deflection-based force-sensing probes are designed and modeled using quasi-static Cosserat and Kirchhoff rod formulations, enabling estimation of both bending and axial contact forces without dedicated tip force sensors. Experimental …

    utk-theses Repository record for State Estimation and Control of Continuum Robots with Applications in Force Sensing and Tissue Palpation (opens in a new tab)

  11. B-CARE: A medical palpation training model for guiding people to monitor their breast health

    Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2024-08-01

    uiuc Repository record for B-CARE: A medical palpation training model for guiding people to monitor their breast health (opens in a new tab)

  12. The role of intraoperative neurostimulation using laryngeal palpation and intraoperative laryngeal ultrasound in optimizing the safety of thyroidectomy /

    … intraoperative neurostimulation using laryngeal palpation and intraoperative laryngeal ultrasound for evaluating the RLN functional status during thyroid surgery. The intraoperative laryngeal ultrasound has never been tested in the intraoperative setting, and the validity of the method was not …

    vilnius Repository record for The role of intraoperative neurostimulation using laryngeal palpation and intraoperative laryngeal ultrasound in optimizing the safety of thyroidectomy / (opens in a new tab)

  13. The effect of training on the inter-examiner and intra-examiner reliability of static palpation for assessing pelvic landmarks

    … and intra-examiner reliability of static palpation of pelvic landmarks. Two groups of final year osteopathic students examined ten asymptomatic female participants for symmetry of pelvic landmarks. One group of examiners attended two training sessions to standardise examination findings …

    vu-aus Download PDF for The effect of training on the inter-examiner and intra-examiner reliability of static palpation for assessing pelvic landmarks (opens in a new tab)

  14. The Accuracy of a Post-Exercise Heart Rate Determined by Electronic Monitoring and Radial Artery Palpation Following Swimming Exercise

    … post-exercise heart rates determined by radial palpation and immediate recovery heart rates determined by electronic monitoring. Fourteen male and four female members of the Eastern Illinois University Swim Program volunteered to be subjects. Each of the subjects swam eight lengths of the pool …

    eiu Repository record for The Accuracy of a Post-Exercise Heart Rate Determined by Electronic Monitoring and Radial Artery Palpation Following Swimming Exercise (opens in a new tab)

  15. VALIDATION AND RELIABILITY OF INERTIAL SENSORS TO MEASURE PELVIC ORIENTATION IN HEALTHY ADULTS

    … pelvic tilt in the sagittal plane require palpation of pelvic landmarks in static standing poses. Inertial sensors may provide a more versatile and reliable option for clinical pelvic tilt measurement. Purpose and Hypothesis The primary purpose of this study was to evaluate the intra-tester …

    sask Repository record for VALIDATION AND RELIABILITY OF INERTIAL SENSORS TO MEASURE PELVIC ORIENTATION IN HEALTHY ADULTS (opens in a new tab)

Page 1 of 19