Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Pan-Tompkins"”.

  1. Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device

    … spacing decreases QRS amplitude, a robust Pan–Tompkins beat detection algorithm can still detect beats for the calculation of Heart Rate and Heart Rate Variability under various noise conditions. A two-Gaussian modeling framework is proposed with iterative Gaussian decomposition for …

    carleton Repository record for Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device (opens in a new tab)

  2. Achieving high-throughput distributed, graph-based multi-stage stream processing

    … Storm and Yahoo S4 using an implementation of Pan Tompkins algorithm which is used to detect QRS complexities of an ECG signal using a 2 node graph. Our results show our solution performs 4 times better than other systems. We also use four level node graph which is used to process smart plug …

    colostate Repository record for Achieving high-throughput distributed, graph-based multi-stage stream processing (opens in a new tab)

  3. Ανάπτυξη εφαρμογής επεξεργασίας καρδιακού σήματος σε φορητή συσκευή για ανίχνευση αρρυθμιών

    … αλγόριθμοι μεταξύ αυτών ο Moving Average, ο Pan Tompkins καθώς και η χρήση κυματιδίων (wavelets) για την εξαγωγή χαρακτηριστικών. Σε τελικό στάδιο θα γίνουν δοκιμές, προσομοιώνοντας την εφαρμογή μας σε καταγραφές πραγματικού χρόνου χρησιμοποιώντας το TCP πρωτόκολλο δικτύου για την επικοινωνία …

    athens Repository record for Ανάπτυξη εφαρμογής επεξεργασίας καρδιακού σήματος σε φορητή συσκευή για ανίχνευση αρρυθμιών (opens in a new tab)

  4. A New Real-Time Algorithm for Obtaining the ECG-derived Respiration (EDR) Signal from the Electrocardiogram (ECG)

    … three major sections. The first section uses the Pan & Tompkins algorithm [3] to obtain the QRS proximity. The second section, estimates the baseline wander noise based on 3rd -order interpolation of the baseline at midpoints in each R-R interval. The final section estimates the EDR signal using …

    sdstate Repository record for A New Real-Time Algorithm for Obtaining the ECG-derived Respiration (EDR) Signal from the Electrocardiogram (ECG) (opens in a new tab)

  5. Sistema para aquisição, monitorização e análise da actividade cardíaca

    … detecção do complexo QRS através do algoritmo de Pan- Tompkins. O modelo de seis estados modela para cada pulso os eventos Q-S, S-T, T, T-P, P e PQ. Neste trabalho foram implementados, testados e comparados dois métodos de extracção de características; a linearização e a transformada wavelet (WT). …

    minho-thes Repository record for Sistema para aquisição, monitorização e análise da actividade cardíaca (opens in a new tab)

  6. Design of fractional-order analog integrated circuits

    … 2nd-order approximation of Continued Fraction Expansion is utilized in order to present a systematic way for describing the design equations of fractional-order generalized transfer functions. To this direction, the design and realization of fractional-order analog integrated circuits offering: …

    greece Repository record for Design of fractional-order analog integrated circuits (opens in a new tab)

  7. Neonatal brain injury detection using advanced deep learning architectures

    … a high quality HRV dataset, an enhanced Pan-Tompkins algorithm was developed to improve R-peak detection robustness in noisy EEG recordings. This enhancement significantly increased the availability and quality of extracted heart rate signals. A hybrid Convolution-Transformer …

    cork Repository record for Neonatal brain injury detection using advanced deep learning architectures (opens in a new tab)

  8. Equine electrocardiography revisited : 12- lead recording, vectorcardiography and the power of machine intelligence

    … QRS detection algorithm outperformed the classic Pan-Tompkins algorithm with a sensitivity of 99.0% versus 91.5% for the Pan-Tompkins algorithm. Next, a novel parallel convolutional neural network architecture was proposed for the feature extraction and classification of the individual beats. The …

    ghent Repository record for Equine electrocardiography revisited : 12- lead recording, vectorcardiography and the power of machine intelligence (opens in a new tab)

  9. Monitorování EKG signálu v reálném čase

    Kľúčovým prvkom pri analyzovaní EKG signálu je detekcia QRS komplexov. QRS komplexy sú najvýraznejšia zložka signálu. V tejto práci je zahrnutý stručný prehľad metód detekcie QRS komplexov v reálnom čase. Na základe rešerše je vybraný vhodný detekčný algoritmus, ktorý je realizovaný v programovom …

    brno-tech Repository record for Monitorování EKG signálu v reálném čase (opens in a new tab)

  10. In-sensor information processing for resource-limited platforms on flexible epidermal substrates

    Moving towards the age of big data, the demand for embedded processing has been drastically increasing to make inference and intelligent decisions at lower architectural layers. The myriad of health conditions that can be treated and analyzed via low-energy embedded information processing kernels …

    uiuc Repository record for In-sensor information processing for resource-limited platforms on flexible epidermal substrates (opens in a new tab)

  11. Principy softwarové detekce QRS

    … V práci jsou realizované tři metody detekce: Pan-Tompkinsův algoritmus, metoda založená na průchodu nulovou hladinou a metoda využívající adaptivní kvantovací práh. Metody byly realizované v prostředí MATLAB a testované na CSE databázi.

    brno-tech Repository record for Principy softwarové detekce QRS (opens in a new tab)

  12. Vestavný systém pro detekci lidské agrese

    Táto bakalárska práca sa zameriava na návrh a implementáciu detekčného systému na rozpoznanie agresie pomocou kombinácie fyziologických zmien, ako sú srdečný tep, intenzita hlasu a odpor kože. Cieľom práce je implementovať systém na vstavanom zariadení a otestovať efektívnosť takéhoto systému …

    brno-tech Repository record for Vestavný systém pro detekci lidské agrese (opens in a new tab)