Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 65 for “"Panavia"”.
-
Effect of Storage Temperatures of Panavia F on the Retention of Prefabricated Dowels
… to their superior retention. The manufacturer of Panavia F 2.0 suggests that the product be stored under refrigerated conditions while not in use, however, there is no literature to support such a rationale. It is possible that these storage/use temperature cycling events may have a deleterious …
-
The Europeanisation of British Defence Procurement in the Cold War : The RAF and the Panavia Tornado
The Panavia Tornado Multi-Role Combat Aircraft (MRCA) project, initiated at the end of the 1960s, signalled a sustained shift in British defence-industrial policy. It brought to a definitive close the long-established practice of unilateral combat aircraft design and production in favour of …
-
Retention glasfaserverstärkter Wurzelkanalstifte in Abhängigkeit vom Befestigungszement
… wurden Clearfil(TM) Core, RelyX(TM) Unicem, Panavia® 21ex, Panavia(TM) F2.0 und Calibra(TM) verwendet. Die Stifte wurden 12 mm tief in artifizielle stiftformkongruente Wurzelkanäle boviner Dentinproben zementiert. Als Kontrollgruppe dienten mit Zinkoxidphosphatzement befestigte ER Kopfstifte …
-
Rasterelektronenmikroskopische Randspaltanalyse adhäsiv zementierter Wurzelkanalstifte aus glasfaserverstärktem Komposit, Zirkoniumdioxid und Titan
… Cement mit ParaPost® Cement Conditioner, PANAVIA® 21 mit ED-Primer®, PANAVIA™ F mit ED-Primer®, Variolink® II mit Excite® DSC, Calibra™ niedrigviskös und Ketac-Cem®. Nach einer Thermowechselbelastung wurden die Proben (jeweils n=8) 1 mm, 5 mm und 9 mm unterhalb des zervikalen Randes mit …
-
Untersuchung des Randspaltes und der Löslichkeit von Befestigungskunststoffen bei Zementierung vollkeramischer Restaurationen mittels Microcomputertomographie
… eingesetzt: Relyx Unicem, Variolink II und Panavia F2.0. Die künstliche Alterung wurde durch Kausimulation parallel mit Thermocycling durchgeführt. Die Löslichkeit der Kunststoffe und der Randspalt der Kronen vor und nach Kausimulation wurden mittels Microcomputertomographie gemessen. Der …
-
AN IN-VITRO COMPARISON OF THE RETENTION OF PREFABRICATED PARALLEL-SIDED VENTED TITANIUM POSTS CEMENTED WITH THREE DIFFERENT DUAL-POLYMERIZABLE RESIN CEMENTS
… Parapost XP posts (size 5) were cemented using Panavia 21(control), Panavia F, RelyX Unicem and Linkmax resin cements. The latter three cements were dual-polymerizable and were not light-activated, and the control cement was autopolymerizable. Also, 140 resin cement samples were fabricated for …
-
Verbundfestigkeit zwischen unterschiedlichen Zirkonoxidmaterialien und adhäsiven Befestigungsmaterialien
… der Prüfkörper wurde mit dem Adhäsivsystem Panavia 21 und die andere Hälfte mit Variolink II an eine mit dem Komposit (Clearfil core) gefüllte Versuchsschraube (Innendurchmesser 3 mm) verklebt. Somit konnten je 12 Proben von jeder Keramik in Kombination mit den zwei Befestigungskompositen …
-
In vitro Untersuchung zur Ermittlung der Scherfestigkeit von unterschiedlichen Befestigungszementen zu zahnfarbenen Restaurationsmaterialien sowie Echtzähnen
… überprüft. Es wurden die Befestigungsmaterialien Panavia™ SA Universal, Visalys® CemCore, G-Cem LinkForce™, Bifix® SE, als Kontrollgruppe Panavia™ V5 und Ketac™ Cem Plus zu den Restaurationsmaterialien Ceramill® zolid ht+ PS (Zirkoniumdioxidkeramik), Enamic® (Hybridkeramik), IPS e.max® CAD …
-
Effect of dentin conditioning on bonding and sealing ability of various resin cements to a ceramic crown
… cements (Variolink Esthetic, Multilink Automix, Panavia SA, and GC FujiCEM 2) were assigned to different dentin conditions (control, immediate dentin sealing [IDS], and delayed dentin sealing [DDS]). The control group received a final restoration immediately, while IDS received OptiBond FL …
-
Cementing zirconia: effect of cement types, polymerization mode, cement space, and air particle abrasion
… The tested cements included: Ceramir C&B (Doxa) Panavia F2.0 (Kuraray); Multilink Automix (Ivoclar); Theracem (Bisco); Duolink (Bisco); Bifix (Shofu); CemEZ (Zest Dental). For testing cements retention, custom made zirconia rings 12.5 mm outer diameter, 5.5 mm height and 6.147 mm inner diameter …
-
Shear bond strength of different cements to printed resins and zirconia
… tested groups (16.18 MPa). SprintRay bonded with Panavia SA materials produced the highest shear bond strength mean values (32.07MPa), followed by Rodin Titan bonded with Panavia V5 and Clearfil (30.91MPa) and Panavia SA (29.50 MPa), and PacDent Rodin Sculpture 2.0 Bonded with Panavia SA (25.51 …
-
Bond Of Dual Cure Resin Cements To Enamel And Dentin In Self Cure Mode
… Primer A & B/Multilink Automix (MA, Ivoclar), Panavia V5 Tooth Primer/Panavia V5 Paste (PanV5, Kuraray Noritake Dental), Optibond XTR/NX3 (NX3,Kerr) and Scotchbond Universal/RelyX Ultimate (RXU,3M); were applied to enamel and dentin using a self-etch, self-cure mode. A 1mm x 1mm block of e.max …
-
The influence of compressive cyclic loading on the retention of cast crown copings cemented to implant abutments.
… retention values for crown copings cemented with Panavia-F cement (5.103, 2.681, 3.178, 2.986MPa) were statistically significantly greater than both KetacCem (0.646, 0.701, 1.083, 0.914MPa) and TempBond non–eugenol (0.074, 0.181, 0.190, 0.303MPa) cements at each compressive cyclic loading …
-
Retentionsstabilität verschiedener "Zemente" bei Verbindung von ZrO2 - Kronen auf Titanklebebasen - eine in-vitro-Studie
… sowie sechs Kunststoffzemente (SpeedCEM Plus, Panavia SA Cement Universal, RelyX Unicem 2 Automix, Pana-via V5, Multilink Hybrid Abutment, VITA ADIVA IA-Cem) wurden untersucht. Von diesen hatten drei selbstadhäsive Eigenschaften (SpeedCEM Plus, Panavia SA Cement Universal, RelyX Unicem 2 …
-
Prüfung der Verbundfestigkeit zwischen zwei NEM-Legierungen nach Anwendung verschiedener Oberflächenkonditionierungsverfahren und Verwendung unterschiedlicher Kompositklebstoffe
… Das Kleben erfolgte mit Compolute ® und PANAVIA F ®. Der Auftrag der Silikatschicht erfolgte mit dem Rocatec-Verfahren und flammenpyrolytisch mit einem modifizierten Gasbrenner. Um den Einfluss des oralen Milieus auf die Verbundfestigkeit zu untersuchen, wurden die Proben einer …
-
Adhäsiver Verbund zum Wurzeldentin in Abhängigkeit von der Wurzelkanaltiefe, dem Befestigungsmaterial, der Spüllösung und der Befestigungsmethode
… (Super-Bond C&B;, Multilink, Panavia F 2.0) nach Herstellerangaben verwendet, wobei zwei verschiedene Befestigungsmethoden benutzt wurden. Zum einen wurde das Befestigungsmaterial nur auf den Stift aufgetragen (S). Zum anderen wurde es auf den Stift aufgetragen und in den Kanal …
-
In-vitro Untersuchung der Polymerisation verschiedener Komposite für die Befestigung zahnfarbener konfektionierter Wurzelstifte in Wurzelkanälen
… von chemisch härtenden (ClearFil, Panavia 21, Parapost), dual härtenden (Variolink II, Calibra, Compolute) und lichthärtenden (Tetric Flow, Tetric Ceram) Kompositen in großlumigen (3 mm Durchmesser und 10 mm Tiefe) Wurzelkanälen boviner Zähne in Kombination mit verschiedenen, …
-
The effect of hydrofluoric acid etching on zirconia bond strength and surface properties
… Evolve) and two resin composite types of cement (Panavia SA Universal and Panavia V5). A cementing jig was used to standardize the cementation process of the titanium pins to the zirconia rings. An Instron was used to obtain the retention load values. The failure load between the zirconia ring and …
-
Evaluation of Three Bonding Agents in the Repair of Fractured Veneered Stainless Steel Crowns
… of three bonding agents (PQ1, C&B Metabond, and Panavia) and one restorative material (Filtek Z250, 3M) in the repair of these fractured stainless steel crown veneers. The clinical significance is to determine the best methods of repairing these crowns in the event of fracture. A total of 90 …
-
Estabilidad cromática de cementos resinosos duales libres de amina: Una revisión sistemática
… estudios in vitro. Cementos libres de amina como Panavia V5, RelyX Ultimate y Variolink Esthetic DC mostraron consistentemente menores ΔE frente a RelyX ARC, Panavia F2.0 y RelyX Unicem. Los fotopolimerizables también evidenciaron alta estabilidad cromática. La magnitud del cambio dependió del …
Page 1 of 4