Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 753 for “"Parallel plate"”
-
Parallel Plate Viscous Dampers
… is to analyze the oscillation of multi-plates immersed in a viscous fluid and the damping forces. The concept of multi-plates oscillating in a viscous fluid with the view of using the plates as a damper is believed to represent a new application. Conventional dampers consist of a …
-
Geodesic focussing in parallel-plate systems
… concerned with the mathematics of the design of parallel-plate equivalents of optical systems, in particular with the parallel-plate equivalent of the parabolic mirror. A parallel-plate microwave system consists of a pair of metal plates, not necessarily plane, which are parallel in the sense …
-
A parallel plate viscoelastometer for molten polymers /
The nonlinear visoelastic behavior that accompanies large transient deformations in high molecular weight polymer melts and concentrated solutions is not at all well-understood, because equipment suitable for the investigation of such phenomena have not been available. This lack of understanding …
-
A study of parallel plate proportional counters
… has led to the construction and study of a parallel plate proportional counter (PPPC). The PPPC was found to be essentially 100% efficient in the detection of 3 MeV protons. Gas gains near 104 were obtained in the pressure range between 177-355 torr. The rise time of the PPPC pulse for a …
-
Controller design for nonlinear micromachined parallel plate actuators
… devices. Nonlinear micromachined electrostatic parallel plate microactuators which work by electrostatic actuation, play an important role in MEMS. Compared with other types of microactuators, these microactuators are the more common and easy to use and it’s because of the fact that they …
-
Salinity (Conductivity) Sensor Based on Parallel Plate Capacitors
… The principle of sensing involves the use of parallel plate capacitors, which minimizes the proximity effects associated with inductive measurement techniques. The barrier properties of two different materials, AZ5214 and Honeywell's ACCUFLO T3027, were investigated for use as the insulation …
-
MICRO OPEN PARALLEL PLATE SEPARATOR: PERFORMANCE AND APPLICATIONS
A comprehensive study of a micro Open Parallel Plate System (µOPPS) is presented. A detailed 3-dimensional computer model that solves a mass balance equation of a solute within the microchannel in the µOPPS was developed. The behavior of the µOPPS was modeled to determine optimal configuration and …
-
Convective Heat Transfer in Parallel Plate Heat Sinks
… heat transfer for single-phase convection in a parallel plate heat sink. A range of modified Reynolds number values between 14.0 and 44.8 was selected based upon pre-existing work to be representative of this transition region. The experimental results were found to be in reasonable agreement …
-
MEMS parallel plate variable capacitor for energy harvesting
… In order to address this problem, a novel MEMS parallel plate variable capacitor for energy harvesting was developed to extract (harvest) wasted energy from undesired mechanical vibrations. This makes it possible to have devices perpetual self-powered. The design, fabrication and …
-
A Sub-Millimeter Parallel-Plate Test of Gravity
… proposed forms of new physics. We performed a parallel-plate test of the gravitational inverse-square law at sub-millimeter distances. Using a tantalum/titanium torsion balance locked in electrostatic feedback, we performed a null search for deviations from uniformity of the gravitational field …
-
A study of a parallel plate ionization chamber
Thesis (M.S.)--Michigan State University of Agriculture and Applied Science. Dept. of Physics & Astronomy, 1961
-
MEMS parallel-plate electrostatic actuator: Modeling, simulation and characterization.
… behavior of an electrostatically actuated parallel-plate actuator which, because of its inherent out-of-plane motion, can be monitored using a laser doppler vibrometer. In order to simulate a real-time fault which may occur due to particulate contamination, fractures or spring softening, …
-
Stress relaxation of glass using a parallel plate viscometer
… parameters in shear of Pyrex¨ glass by using a Parallel Plate Viscometer (PPV). The PPV machine was originally created to measure the viscosity of glass solid cylinders by compression. It is used in this study for creep-recovery tests of glass samples. With this study we want to know if we are …
-
Impedance-Based Water-Quality Monitoring Using Parallel Plate Method
The application of electromagnetic (EM) waves to measure the electrical properties (dielectric constant and loss tangent) of materials is a well-known approach. The electrical properties can be used to indirectly measure several physical properties of solutions in water such as the concentration …
Page 1 of 38