  1. Isolating Power Amplifiers for Parallel Transmit MRI

    A radio frequency parallel transmitter was developed for magnetic resonance imaging. Eight channels of vector modulation and isolating power amplifiers were constructed so that the performance of different amplifier architectures could be investigated. An eight channel system was implemented and …

    tamu Repository record for Isolating Power Amplifiers for Parallel Transmit MRI (opens in a new tab)

  2. Radiofrequency safety modelling of parallel transmit magnetic resonance imaging

    … (PRF) based MR thermometry in the context of parallel transmit (pTx) MRI is described in Chapter 4. Also described in this chapter is a 3D gradient-echo sequence used to monitor temperature-induced phase shifts, as well as the required image reconstruction techniques and field-stabilisation …

    oxford Repository record for Radiofrequency safety modelling of parallel transmit magnetic resonance imaging (opens in a new tab)

  3. Eight-Channel Head Array and Control System for Parallel Transmit/Receive Magnetic Resonance Imaging

    … wavelength causes potential inhomogeneity in the transmit field of the RF coil, resulting in non-uniform excitations. Susceptibility effects are also more pronounced at high field strengths, and can cause local distortions in the field and create areas of signal dropout. Parallel transmit is one …

    tamu Repository record for Eight-Channel Head Array and Control System for Parallel Transmit/Receive Magnetic Resonance Imaging (opens in a new tab)

  4. Motion estimation using radiofrequency scattering of a parallel transmit coil for cardiac magnetic resonance imaging at 7T

    … are based on radiofrequency (RF) scattering of a parallel-transmit coil and directly assess the heart motion, independent of the electrical activity of the heart. A cardiac motion signal is derived with a high SNR and with a number of potential gating features, which have a high accuracy when …

    oxford Repository record for Motion estimation using radiofrequency scattering of a parallel transmit coil for cardiac magnetic resonance imaging at 7T (opens in a new tab)

  5. Quantitative Evaluation of Microstrip, Dipole and L/C Loop Parallel Transmit (pTx) Arrays for UHF MR Imaging

    … in depicting soft tissue pathologies, offering unparalleled detail for clinical diagnosis and biomedical research. Radiofrequency coil arrays enhance sensitivity, scan speed, and image consistency across the brain to optimize performance further. Advanced UHF scanners are equipped with 8 or 16 …

    buffalo Repository record for Quantitative Evaluation of Microstrip, Dipole and L/C Loop Parallel Transmit (pTx) Arrays for UHF MR Imaging (opens in a new tab)

  6. New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI

    … design an eight-channel array coil that is both transmit and receive, and could be used for both types of studies. We focused on optimizing the array for the application of small field-of-view (FOV) excitation, which allows zooming into a region-of-interest (ROI). For example, in breast imaging …

    manitoba Repository record for New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI (opens in a new tab)

  7. Parallel transmission technologies for imaging the brain and body with 7 tesla MRI

    … field non-uniformity using technology known as parallel transmission. Although, in order to provide a robust subject-specific improvement the non-uniform radiofrequency field must first be mapped in a process known as “B1+ mapping”.</p> <p>To begin, I will go through some essential magnetic …

    oxford Repository record for Parallel transmission technologies for imaging the brain and body with 7 tesla MRI (opens in a new tab)

  8. Real-time motion correction for Magnetic Resonance Imaging of the human brain at 7 Tesla

    … which includes field strengths of 7T and above. Transmit B +1 field inhomogeneity is also higher, causing uneven signal intensity and linking to an uneven SAR distribution, which is also higher than at lower field strengths. The potential for higher spatial resolution imaging can also result in …

    glasgow Repository record for Real-time motion correction for Magnetic Resonance Imaging of the human brain at 7 Tesla (opens in a new tab) Download PDF for Real-time motion correction for Magnetic Resonance Imaging of the human brain at 7 Tesla (opens in a new tab)

  9. Multi-rate access schemes and successive interference cancellation for wireless multimedia MC-CDMA communications

    … such as voice, video and higher rate data can be transmitted seanilessly through one MC-CDMA infrastructure. The performance of the multi-rate MC-CDMA is mainly limited by multiple access interference (MAI). For example, in the MFSL MC-CDMA systems, the interference is not only presented among …

    njit Repository record for Multi-rate access schemes and successive interference cancellation for wireless multimedia MC-CDMA communications (opens in a new tab)

  10. Application of Parallel Transmission to Ultra-High Field Magnetic Resonance Spectroscopy and Imaging

    … of imaging at such extreme field strength is the transmit B1 field inhomogeneity. The technique of parallel transmission has been proposed to mitigate such challenge and provides opportunities to explore new acquisition methods. To take advantage of these capabilities, this thesis investigates its …

    umn Repository record for Application of Parallel Transmission to Ultra-High Field Magnetic Resonance Spectroscopy and Imaging (opens in a new tab)

  11. A 64 Channel Transmit System for Single Echo Acquisition MRI

    … based methods have reached the safety limit. Parallel receiving techniques achieve accelerations by reducing phase encoding steps. Among these methods, SEA Imaging achieved the highest possible acceleration by completely eliminating phase encoding. However, SEA imaging is limited to thin …

    tamu Repository record for A 64 Channel Transmit System for Single Echo Acquisition MRI (opens in a new tab)

  12. Control System for Phase-Only B1 Steering in High Field Magnetic Resonance Imaging

    … requires the ability to change phase for transmit power (TX) on each channel of a parallel transmit coil. While a simple approach to this problem would be to use a collection of coaxial cables of various lengths, this is very cumbersome and limits the functionality of the system. …

    tamu Repository record for Control System for Phase-Only B1 Steering in High Field Magnetic Resonance Imaging (opens in a new tab)

  13. High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI

    … and B0 inhomogeneity and higher SAR deposition. Parallel transmit (PTx) combined with more advanced pulse design methods is a flexible solution to overcome B+1 inhomogeneity. During my PhD I investigated how to compare different qMRI methods and developed two RF pulse design methods for pTx …

    kings Repository record for High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI (opens in a new tab) Download PDF for High resolution imaging of tissue properties with optimized precision using Ultra High Field MRI (opens in a new tab)

  14. B1 Mapping for Magnetic Resonance Imaging

    … on a linear relationship between flip angle and transmit voltage. That assumption breaks down when a 3D slab-selective excitation is used. 3D slab-selective excitation is a common technique used to reduce the field-of-view (FOV) in MRI, which can directly reduce scan time. The problem with …

    byu Repository record for B1 Mapping for Magnetic Resonance Imaging (opens in a new tab) Download PDF for B1 Mapping for Magnetic Resonance Imaging (opens in a new tab)