Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 20 for “"Paravalvular leak"”.
-
Biomechanical analysis of aortic valve calcification and post-procedural paravalvular leak
… risk for open heart surgery. Post-procedural paravalvular leak (PVL) is a common complication which occurs around the implanted stent in a significant population of patients who undergo valve replacement, requiring significant interventions. The overarching hypothesis of this research is that …
-
Generalized CFD Study of Paravalvular Leak Associated with Transcatheter Aortic Valve Replacement
Aortic stenosis is a growing health issue that is commonly treated by valve replacement. Transcatheter aortic valve replacement is a newer medical device being used to treat patients with aortic stenosis but poses a different set of problems than its predecessors. This study is an investigation …
-
Energetic and Hemodynamic Characteristics of Paravalvular Leak Following Transcatheter Aortic Valve Replacement
… medium term results are very promising, however paravalvular leak (PVL) post-TAVR still represents a significant complication. PVL post-TAVR is shown to be an independent predictor of short-term and long-term mortality. Despite, its importance and prevalence, with a wide range of reported …
-
Incidence and risk factors for mitral paravalvular leak and comparison of the treatment modalities /
Introduction: Mitral paravalvular leak (PVL) is well-known complication. Repeat surgery was the only effective therapy. Recently, catheter-based PVL closure has gained global spread. The outcomes for treatment of this complication are unknown. Aim: To compare redo surgery versus surgical …
-
Patient-specific finite element modeling of biomechanical interaction in transcatheter aortic valve implantation
… of TAVI, adverse clinical events, such as paravalvular leak, aortic rupture, and coronary occlusion, have been reported extensively. Many of these adverse events can be explained from the biomechanics perspective. Therefore, an in-depth understanding of biomechanical interaction between the …
-
Συσχέτιση των κλινικών αποτελεσμάτων με βάση την κύρια ένδειξη διακαθετηριακής σύγκλεισης παραβαλβιδικής ανεπάρκειας: αιμόλυση ή καρδιακή ανεπάρκεια
Background: Paravalvular leak (PVL) is an important complication following surgical heart valve replacement and may present with symptoms of heart failure, hemolytic anemia, or a combination of both. Transcatheter paravalvular leak closure (TPVLC) is a therapeutic option for selected patients with …
-
Low flow low gradient aortic valve stenosis: the role of transcatheter aortic valve replacement (TAVR)
… 95% C.I: 1.645 - 5.809) and at least moderate paravalvular leak (PVL) post-TAVR (HR: 1.456 , 95% C.I.: 1.106 - 1.792 ) were significant independent predictors of late global mortality. LF-LG patients and LF-HG patients exhibited a significant increase in LVEF at 1-year follow-up. A lower LVEF …
-
Nauji prietaisai struktūrinės širdies ligos gydymui /
… valves were prone to developing higher grade paravalvular leak. However, newer valve models of both types demonstrated improved results. Although golden treatment standard for mitral regurgitation is surgical option, the need for percutaneous interventions is high as well, since around half of …
-
Mitralinio vožtuvo paravalvulinių fistulių susidarymo priežasčių nustatymas, jų gydymo metodų paliginimas /
Introduction: Mitral paravalvular leak (PVL) is well-known complication. Repeat surgery was the only effective therapy. Recently, catheter-based PVL closure has gained global spread. The outcomes for treatment of this complication are unknown. Aim: To compare redo surgery versus surgical …
-
Effect of diastolic dysfunction on outcomes of patients with severe aortic stenosis undergoing transcatheter aortic valve replacement
… the role of DD in patients that develop paravalvular leak (PVL).Results: Over a mean follow-up time of 13 months, severe DD was associated with an increased risk for the outcome measure (HR 2.02 (1.23-3.30), p=0.005). However, this association was lost in a propensity-matched cohort that …
-
Computed tomography aortic valve calcium scoring and its association with adverse events following transcatheter aortic valve implantation (TAVI)
… of a combination of post-TAVI outcomes (paravalvular leak ≥ mild, implant-related conduction disturbances, 30-day mortality, post-procedural stroke, annulus rupture, and device migration). The Akaike information criterion was used to select variables for the multivariable regression …
-
Σύγκριση της διαδερμικής διά της υποκλειδίου αρτηρίας σε σχέση με τη διαμηριαία προσπέλαση τοποθέτηση αορτικής βαλβίδας σε ασθενείς με στένωση αορτικής βαλβίδος
… were reported. The prevalence of more than mild paravalvular leak atdischarge was 14.3 vs. 13.0% in the subclavian vs. femoral group, respectively (p = 0.838).Thirty-day mortality was 8.34 vs. 3.2% (p = 0.179) and one year mortality was 13.9 vs.10.8% in the subclavian vs. femoral group (p = …
-
Comparative outcomes of surgical versus transcatheter interventions in the treatment of aortic stenosis /
… rate of permanent pacemaker implantation and paravalvular leak, whereas SAVR was associated with increased bleeding and a higher incidence of postoperative atrial 2 fibrillation. However, although surgical valves are generally considered more durable, the long-term evidence comparing …
-
Biomechanics of transcatheter aortic valve replacement for bicuspid aortic valves
… when treating BAV patients with TAVR are paravalvular leak (PVL), a known associate of increased patient mortality, and long-term durability. Highly calcified BAV patients have shown increased incidence of PVL following TAVR. Additionally, stent asymmetry and undersizing are common in BAV …
-
Transcatheter aoritc valve implantation as a first-line strategy in low-risk young adults with aortic stenosis
… such as permanent pacemaker implantation and paravalvular leak whose consequences compound across a longer life. Finally, the conventional framing of transcatheter against conventional surgical replacement is argued to be too narrow for the young patient, in whom alternative strategies, most …
-
Die Entwicklung eines neuen Kalzium-Scores zur Vorhersage der paravalvulären Leckage bei der Transkatheter-Aortenklappenimplantation
Hintergrund: Die Transkatheter-Aortenklappenimplantation (TAVI) ist eine weitverbreitete Behandlungsoption für Patienten mit einer schweren symptomatischen Aortenklappenstenose. Trotz enormer Forschungserfolge und Verbesserungen des Implantationsverfahrens, gehört die paravalvuläre Leckage (PVL) …
-
Design parameters and physiologic factors governing mitral valve annular loading following device implantation
… Second, TMV radial expansion forces and paravalvular leakage dynamics were quantified in explanted porcine hearts, as functions of the device’s profile. Findings quantitatively demonstrated key advantages of a non-circular TMV shape, implications of annular oversizing, and criteria for …
-
Η επίδραση της προδιαστολής πριν τη διακαθετηριακή εμφύτευση βιοπροσθετικής αυτοεκπτυσσόμενης αορτικής βαλβίδας στη βραχυπρόθεσμη και μακροπρόθεσμη έκβαση των ασθενών που υποβάλλονται σε αυτήν
… and after (stage-3) final bioprosthesis release. Paravalvular regurgitation (PVR) was assessed after implantation, at discharge, at 1st and 6th month after TAVI and 1-year clinical follow-up were recorded. Overall, from stage-1 to stage-3, prosthesis migrated toward the left ventricle,in both …
-
Άμεσες και απώτερες επιπτώσεις που παρατηρούνται σε ασθενείς με βαλβιδική ανεπάρκεια ή παραβαλβιδική διαφυγή μετά από διαδερμική εμφύτευση αορτικής βαλβίδας
Introduction: The Transcatheter Aortic Valve Implantation (TAVI) is an adequately documented treatment option for patients with severe aortic valve stenosis. Its current indications are not limited to patients who are characterized as inoperable or high risk, but have also been extended to include …