Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"Paravalvular leak"”.

  1. Biomechanical analysis of aortic valve calcification and post-procedural paravalvular leak

    … risk for open heart surgery. Post-procedural paravalvular leak (PVL) is a common complication which occurs around the implanted stent in a significant population of patients who undergo valve replacement, requiring significant interventions. The overarching hypothesis of this research is that …

    colostate Repository record for Biomechanical analysis of aortic valve calcification and post-procedural paravalvular leak (opens in a new tab)

  2. Generalized CFD Study of Paravalvular Leak Associated with Transcatheter Aortic Valve Replacement

    Aortic stenosis is a growing health issue that is commonly treated by valve replacement. Transcatheter aortic valve replacement is a newer medical device being used to treat patients with aortic stenosis but poses a different set of problems than its predecessors. This study is an investigation …

    houston Repository record for Generalized CFD Study of Paravalvular Leak Associated with Transcatheter Aortic Valve Replacement (opens in a new tab)

  3. Energetic and Hemodynamic Characteristics of Paravalvular Leak Following Transcatheter Aortic Valve Replacement

    … medium term results are very promising, however paravalvular leak (PVL) post-TAVR still represents a significant complication. PVL post-TAVR is shown to be an independent predictor of short-term and long-term mortality. Despite, its importance and prevalence, with a wide range of reported …

    concordia Download PDF for Energetic and Hemodynamic Characteristics of Paravalvular Leak Following Transcatheter Aortic Valve Replacement (opens in a new tab)

  4. Incidence and risk factors for mitral paravalvular leak and comparison of the treatment modalities /

    Introduction: Mitral paravalvular leak (PVL) is well-known complication. Repeat surgery was the only effective therapy. Recently, catheter-based PVL closure has gained global spread. The outcomes for treatment of this complication are unknown. Aim: To compare redo surgery versus surgical …

    vilnius Repository record for Incidence and risk factors for mitral paravalvular leak and comparison of the treatment modalities / (opens in a new tab)

  5. Patient-specific finite element modeling of biomechanical interaction in transcatheter aortic valve implantation

    … of TAVI, adverse clinical events, such as paravalvular leak, aortic rupture, and coronary occlusion, have been reported extensively. Many of these adverse events can be explained from the biomechanics perspective. Therefore, an in-depth understanding of biomechanical interaction between the …

    gatech Repository record for Patient-specific finite element modeling of biomechanical interaction in transcatheter aortic valve implantation (opens in a new tab)

  6. Low flow low gradient aortic valve stenosis: the role of transcatheter aortic valve replacement (TAVR)

    … 95% C.I: 1.645 - 5.809) and at least moderate paravalvular leak (PVL) post-TAVR (HR: 1.456 , 95% C.I.: 1.106 - 1.792 ) were significant independent predictors of late global mortality. LF-LG patients and LF-HG patients exhibited a significant increase in LVEF at 1-year follow-up. A lower LVEF …

    greece Repository record for Low flow low gradient aortic valve stenosis: the role of transcatheter aortic valve replacement (TAVR) (opens in a new tab)

  7. Nauji prietaisai struktūrinės širdies ligos gydymui /

    … valves were prone to developing higher grade paravalvular leak. However, newer valve models of both types demonstrated improved results. Although golden treatment standard for mitral regurgitation is surgical option, the need for percutaneous interventions is high as well, since around half of …

    vilnius Repository record for Nauji prietaisai struktūrinės širdies ligos gydymui / (opens in a new tab)

  8. Mitralinio vožtuvo paravalvulinių fistulių susidarymo priežasčių nustatymas, jų gydymo metodų paliginimas /

    Introduction: Mitral paravalvular leak (PVL) is well-known complication. Repeat surgery was the only effective therapy. Recently, catheter-based PVL closure has gained global spread. The outcomes for treatment of this complication are unknown. Aim: To compare redo surgery versus surgical …

    vilnius Repository record for Mitralinio vožtuvo paravalvulinių fistulių susidarymo priežasčių nustatymas, jų gydymo metodų paliginimas / (opens in a new tab)

  9. Effect of diastolic dysfunction on outcomes of patients with severe aortic stenosis undergoing transcatheter aortic valve replacement

    … the role of DD in patients that develop paravalvular leak (PVL).Results: Over a mean follow-up time of 13 months, severe DD was associated with an increased risk for the outcome measure (HR 2.02 (1.23-3.30), p=0.005). However, this association was lost in a propensity-matched cohort that …

    greece Repository record for Effect of diastolic dysfunction on outcomes of patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (opens in a new tab)

  10. Computed tomography aortic valve calcium scoring and its association with adverse events following transcatheter aortic valve implantation (TAVI)

    … of a combination of post-TAVI outcomes (paravalvular leak ≥ mild, implant-related conduction disturbances, 30-day mortality, post-procedural stroke, annulus rupture, and device migration). The Akaike information criterion was used to select variables for the multivariable regression …

    fu-berlin Repository record for Computed tomography aortic valve calcium scoring and its association with adverse events following transcatheter aortic valve implantation (TAVI) (opens in a new tab)

  11. Comparative outcomes of surgical versus transcatheter interventions in the treatment of aortic stenosis /

    … rate of permanent pacemaker implantation and paravalvular leak, whereas SAVR was associated with increased bleeding and a higher incidence of postoperative atrial 2 fibrillation. However, although surgical valves are generally considered more durable, the long-term evidence comparing …

    vilnius Repository record for Comparative outcomes of surgical versus transcatheter interventions in the treatment of aortic stenosis / (opens in a new tab)

  12. Biomechanics of transcatheter aortic valve replacement for bicuspid aortic valves

    … when treating BAV patients with TAVR are paravalvular leak (PVL), a known associate of increased patient mortality, and long-term durability. Highly calcified BAV patients have shown increased incidence of PVL following TAVR. Additionally, stent asymmetry and undersizing are common in BAV …

    gatech Repository record for Biomechanics of transcatheter aortic valve replacement for bicuspid aortic valves (opens in a new tab)

  13. Transcatheter aoritc valve implantation as a first-line strategy in low-risk young adults with aortic stenosis

    … such as permanent pacemaker implantation and paravalvular leak whose consequences compound across a longer life. Finally, the conventional framing of transcatheter against conventional surgical replacement is argued to be too narrow for the young patient, in whom alternative strategies, most …

    bu Repository record for Transcatheter aoritc valve implantation as a first-line strategy in low-risk young adults with aortic stenosis (opens in a new tab)

  14. Die Entwicklung eines neuen Kalzium-Scores zur Vorhersage der paravalvulären Leckage bei der Transkatheter-Aortenklappenimplantation

    Hintergrund: Die Transkatheter-Aortenklappenimplantation (TAVI) ist eine weitverbreitete Behandlungsoption für Patienten mit einer schweren symptomatischen Aortenklappenstenose. Trotz enormer Forschungserfolge und Verbesserungen des Implantationsverfahrens, gehört die paravalvuläre Leckage (PVL) …

    fu-berlin Repository record for Die Entwicklung eines neuen Kalzium-Scores zur Vorhersage der paravalvulären Leckage bei der Transkatheter-Aortenklappenimplantation (opens in a new tab)

  15. Design parameters and physiologic factors governing mitral valve annular loading following device implantation

    … Second, TMV radial expansion forces and paravalvular leakage dynamics were quantified in explanted porcine hearts, as functions of the device’s profile. Findings quantitatively demonstrated key advantages of a non-circular TMV shape, implications of annular oversizing, and criteria for …

    gatech Repository record for Design parameters and physiologic factors governing mitral valve annular loading following device implantation (opens in a new tab)