Power Transformer Partial Discharge (PD) Acoustic Signal Detection using Fiber Sensors and Wavelet Analysis, Modeling, and Simulation
… The second part of this thesis focuses on the PD signal analysis from an on-site PD measurement of the in-house design fiber optic sensors (by Virginia Tech, Center for Photonics Technology). Several commercial piezoelectric transducers (PZTs) were also used to compare the measurement results. …
-
A Study on Insulation Problems in Drive Fed Medium Voltage Induction Motors
… by non-linear potential distributions; increased partial discharge (PD) activities due to overshoots in pulse waveforms; and built-up space charge by high frequency signals. The present work therefore addresses the problems associated with enamelled wires and groundwall insulation in motor stator …
-
Diagnostika vysokonapěťových kondenzátorů pro kaskádní napěťový násobič
… nalezení vhodné metody měření částečných výbojů (Partial discharge, PD) vysokonapěťových kondenzátorů v dielektriku. V teoretické části této diplomové práci je popsán mechanismus vzniku částečných výbojů a škodlivé působení částečných výbojů na izolaci vysokonapěťových kondenzátorů. Je popsána …
-
Inspection frequency optimization and partial discharge monitoring for condition based maintenance of substations
… and the other to develop an efficient partial discharge (PD) diagnostic technique for gas-insulated substations (GIS). Three contributions have been made through these two objectives. The first contribution is the development of an adaptive reliability model, which adapts to changing …
-
Noise reduction and source recognition of partial discharge signals in gas-insulated substation
To minimise the failure risk of GIS due to partial discharge (PD), PD diagnosis system is required to detect and identify the harmful PD reliably and efficiently. In this thesis, two major issues for achieving successful PD diagnosis, namely: influence of noises and extraction of effective features …
-
Online partial discharge measurement in a high noise environment
This thesis deals with the online measurement of partial discharge (PD) in a high-voltage direct current (HVDC) converter station. The HVDC station is a particularly challenging environment for PD measurement due to elevated interference levels caused from the switching of the thyristor-controlled …
-
Interpretation of UHF signals produced by partial discharges in oil-filled power transformers
… of time by the cumulative adverse effects of partial discharge (PD) activity. Recognition of PD in power transformers is important because early detection can allow utilities to take appropriate preventative measures in order that costly failures do not occur. In this work, a range of on-line …
-
Sensor UHF elíptico para detecção de descargas parciais
… geometry, aiming for its application of partial discharge (PD) detection, as a UHF sensor. To improve the performance of the proposed antenna, cascaded frequency selective surfaces (FSS), using double square loops as a unit cell element, were designed and evaluated. Antenna reflection …
-
A Comparative Analysis of Experimental and Computational Methods for Evaluating Partial Discharge Inception Voltage on Printed Circuit Boards
Partial discharge (PD) presents a significant reliability concern in medium-voltage (MV) and high-voltage (HV) systems, particularly as power electronics applications continue to push to higher voltage levels. One aspect of MV/HV system design that has not received much treatment in the literature …
-
Statistical system identification and classification using Laguerre functions
… classification methods to automatically identify partial discharge (PD) signals from multiple sources and developing new system identification techniques to help increase the accuracy of these classifications. We use a Laguerre functional basis to approximate PD signal waveforms, obtained through …
-
A new approach to partial discharge measurements for testing electrical insulation systems
Partial discharge (PD) data has been recorded simultaneously using the conventional IEC60270 `apparent charge' measurement technique and the more recent Radio Frequency (RF) method. Due to the different responses of each system, combined measurement allows additional information on the nature of …
-
The Investigation of Tree-Retardant Ethylene Propylene Rubber Insulated Medium Voltage Cable as an Alternative Underground Cable for Victorian Power Distribution Network
… and elongation at break. Measurements of Partial Discharge (PD) were also conducted prior and after cable heating at service temperature. The results of the thermal ageing test and PD measurements were visually presented through graphs and plots. For the thermal ageing, a theoretical life …
-
An optic fiber sensor for partial discharge acoustic detection
Partial discharge (PD) is a very common problem in operating power transformers and is one of the factors that could lead to failure of power transformers, leading to power outage and expensive repairs. The acoustic wave induced by PD can be measured and used for monitoring, diagnosing, and …
-
FDTD modelling of partial discharge in high voltage cables
Partial discharge (PD) is recognized as an effective insulation diagnostic tool. PD measurement on high voltage (HV) cables is performed to evaluate the cable insulation conditions and high frequency current transformers (HFCTs) are widely used as the PD sensor. Detected PD signals can be subject …
-
A Study of the Detection of Defects in Ceramic Insulators Based on Radio Frequency Signatures.
… ultimately results in the initiation of partial discharge (PD) activity. Because insulation failure and the consequent breakdown of power equipment can occur due to the cumulative adverse effects of partial discharges, it is important to detect PD activity in its early stages. Current …
-
Partial discharge detection in cable systems
… with the development of suitable methods for partial discharge (PD) detection, quantification and location within high voltage cable systems. Acoustic emission (AE) techniques are suitable for PD on-line monitoring. This approach is free from electrical interference. Application of acoustic …
-
Partial Discharge Monitoring by the UHF Method in Power Transformers
… in power system equipment, the level of partial discharge (PD) activity should be continuously monitored to avoid unexpected breakdowns. PD occurrence can accelerate the aging process of insulation in high voltage equipment and result in catastrophic failure if the associated defects are …
-
Partial Discharges: Experimental Investigation, Model Development, and Data Analytics
… aging factors in insulation systems known as partial discharge (PD) is targeted. PD phenomenon has been studied for more than a century and yet new technologies still demand the investigation of PD impact. Nowadays, electrification is penetrating into various fossil-fuel-based industries such …
-
A framework for developing a prognostic model using partial discharge data from electrical trees
… diagnosis of the fault can be achieved based on partial discharge (PD) analysis. Nonetheless, after diagnosis of a defect, engineers need to know how long they have to take action. This requires prognosis of remaining insulation life. The progression of a defect is far less well understood than …
-
The excitation of UHF signals by partial discharge in gas insulated substations
… ultra-high frequency (UHF) signals excited by partial discharge (PD) sources inside gas insulated substations (GIS). PD is indicative of defects in the insulation system and by using couplers mounted at intervals along the GIS, the corresponding bursts of UHF signal can be extracted. This is …