Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 6 of 6 for “"Partial Discharge Measurement"”.
-
Online partial discharge measurement in a high noise environment
This thesis deals with the online measurement of partial discharge (PD) in a high-voltage direct current (HVDC) converter station. The HVDC station is a particularly challenging environment for PD measurement due to elevated interference levels caused from the switching of the thyristor-controlled …
-
Design and Implementation of Partial Discharge Measurement Sensors for On-line Condition Assessment of Power Distribution System Components
… easily applicable to the network. In this work partial discharge (PD) measurements have been considered for insulation condition assessment of distribution system components such as overhead covered conductors (CCs) and cables. A high frequency Rogowski coil induction sensor is designed for this …
-
EVALUATION OF THE LIFE EXPECTANCY OF UNDERGROUND POWER CABLES
… tests investigated to AC high voltage withstand, partial discharge measurement, capacitance measurement, DC high voltage for insulation resistance measurement and impulse breakdown. The length of the test samples was found to be too short for practical breakdown testing, suffering from flashover, …
-
Using online partial discharge measurements to optimise asset management of medium voltage cable terminations
… This dissertation focuses on using online partial discharge measurements to optimize asset management of medium voltage cable terminations. Cable terminations as an asset portfolio within asset management is discussed with reference to international asset management standard. The importance …
-
A Study of Medium and High Voltage Form-Wound Coil Turn-to-Turn Insulation of Converter Fed Rotating Machines
… voltage pulse generator, and an antenna based PD measurement system, were implemented in order to investigate significant factors affecting insulation system using PD activity measurements and times-to-failure experiments. The experimental results were used to identify the significant parameters …
-
Poruchy a závady kabelových souborů
Cílem této diplomové práce je definovat kabelové soubory a popsat závady a poruchy, které se na kabelových souborech mohou objevit. V teoretické části práce je kabelový soubor rozdělen na jednotlivé části, které jsou blíže popsány. Uvedeny jsou také diagnostické metody, které je možné použít k …