Results 1 to 20 of 20 for “"Partial discharges (PD)"”
-
Partial discharge detection in medium voltage stators using two independent detection schemes
… that contribute towards insulation breakdown is Partial Discharges (PD). In this work, an attempt is made to come up with an accurate, reliable and repeatable procedure to test medium voltage stators for PD." -- Abstract.
-
Low air pressure partial discharge recognition using statistical analysis of time-domain pulse features
… of electrical power supplies that may cause partial discharges (PD). At higher voltages, the partial discharges can be disruptive and cause insulation failure. Furthermore, an aircraft experiences a wide range of operating pressures during ascending and descending. The air pressure at high …
-
Analysis of Partial Discharge Pulse Height Distribution Parameters
Partial Discharges (PD) have been traditionally used to assess the state of any insulation system and its remnant life. In earlier work, Perspex (PMMA) samples with a needle plane gap have been aged with AC voltage. Their tree growth was monitored simultaneously by collecting PD at regular …
-
Numerical modelling of partial discharge in high-voltage systems
Partial discharges (PD) are a key failure component in high voltage insulation, typically emerging from locally increased electric fields around voids and impurities. For the case of PD phenomenon, they were modelled and simulated using the Finite Integration Technique (FIT) implemented in CST …
-
Análise do processo de wavelet shrinkage na extração de ruído de sinais de descargas parciais e separação dos defeitos associados
… of signals related to the phe- nomenon of partial discharges (PD), which manifests itself in high voltage equip- ment. Initially, in the field of noise extraction using the wavelet transform, new optimized thresholding functions are proposed to treat the wavelet coefficients of the PD …
-
Localização de fontes de descargas parciais baseada em técnicas radiométricas
… degradation is to identify the occurrence of partial discharges (PD). Early detection of defects in insulation enables the programming of electric power equipment maintenance activities. Thus, the electrical system can operate more reliably and with fewer interruptions. In addition to …
-
Testing and modelling nanostructured insulation for capacitor and cables used for storage and delivery of electrical energy
The measurement of partial discharges (PD) is a commonly used tool to evaluate the healthiness of electrical insulation materials in high voltage systems such as HVDC cables. PD measurement is an important non-destructive test from predictive maintenance and asset management of high voltage …
-
UHF monitoring of partial discharges in high voltage transformers
… of Ultra High Frequency (UHF) signals from Partial Discharges (PD) to detect and characterise defect signals in multi-source environments. PD is the result of partial bridging of the insulation medium between electrodes, and can be a precursor to eventual flashover. UHF monitoring techniques …
-
Enhancing the reliability of electric transportation motors through insulation coordination and improved qualification
… probability. In particular, the appearance of partial discharges (PD) is disruptive on the reliability of the drive, especially under fast repetitive transients. Extensive experimental activity has been performed to extend the body of knowledge on PD inception, endurance under PD activity, and …
-
Radiometric partial discharge characterisation
… are manifestations of this condition, called partial discharges (PD) and because of this, PD have been subject of an extensive study and investigation. PD identification relies on the intrinsic characteristics of the generated discharge. This thesis shows the behaviour of radiated discharge …
-
On-line measurement of partial discharges in high voltage rotating machines.
… high voltage rotating machines by detection of partial discharges (PD) which are indicative of stator insulation degradation. Partial discharge manifests itself in various forms which can be detected using various electrical and non-electrical techniques. The electrical method of detecting small …
-
DETECTION AND DIAGNOSIS OF PARTIAL DISCHARGES UNDER REPETITIVE PULSED VOLTAGE EXCITATION
… high-frequency switching inherent in PWM induces partial discharges (PD) within motor winding insulation, often causing premature insulation failure and reduced motor lifespan. Furthermore, rapid voltage rise times, fast switching frequencies and high dv/dt associated with PWM complicate PD …
-
Partial discharge diagnostics in medium voltage cables
… based maintenance strategies utilizing online partial discharge monitoring technologies. Partial discharges (PD) are the early symptoms of insulation degradation that can ultimately lead to complete breakdown of the insulation system.Presented in this thesis are novel contributions to the area …
-
Automated localization of partial discharge in transformer winding using noninvasive capacitively-coupled pulse injection
… can cause serious problems. Local electrical discharges called partial discharges (PD) can occur in transformer insulation, causing damage to the insulation over time. To ensure reliable transformer operation, PD detection and localization are essential. It is, however, difficult to locate the …
-
Localization of partial discharge in power transformer winding using electromagnetic time reversal and reciprocity
… and reliable power delivery to customers. Partial discharges (PD), which are localized electrical discharges in transformer insulation, can lead to insulation failure if they are not detected and accurately localized. To enable early detection and localization of PDs in transformer …
-
Pre-breakdown phenomena in ester-based fluids for potential application in transformers serving in cold climatic regions
… count, turbidity, and UV spectroscopy) on partial discharges (PD) and breakdown characteristics. The complete analysis is carried out for the liquids having pour point less than -50°C with those including a mineral oil (MO) and two synthetic ester liquids (SE1 and SE2). Changes in discharge …
-
A Study of Stress Grading System of Medium Voltage Motor Fed by Adjustable Speed Drives
… Any local high electric field produces surface partial discharges (PD) on the stress grading system that may lead to immature insulation failure. Limiting the temperature rise and controlling the local electric field to avoid surface discharges and hot spots using an appropriate stress grading …
-
Study of partial discharge and gas breakdown phenomena at a triple junction under various pressure and temperature conditions
… tensions-seuil d'amorçage/d'extinction des DP (Partial Discharge Inception Voltage, PDIV/Partial Discharge Extinction Voltage, PDEV) et la tension de claquage du gaz en surface de l'isolant solide (Flashover Voltage, FOV).Dans ce contexte, un dispositif expérimental a été conçu et exploité dans …
-
Recherche de matériaux isolants pour la conception d'une nouvelle génération de connecteurs électriques haute tension : influence de la pollution sur les phénomènes de décharges partielles du contournement et de claquage
… thermodurcissables époxydes ou élastomères en EPDM, capables de résister à plusieurs contraintes : thermique, électrique, mécanique, chimique et climatique. La partie expérimentale concerne, tout d’abord, la mesure de la tension de contournement, de l’activité des décharges partielles se …
-
Vliv tvaru napětí na částečné výboje v izolačních systémech vn
Tato bakalářská práce se zabývá vlivem různých tvarů napětí běžně se vyskytujících ve vysokonapěťových (VN) sítích na vznik a chování částečných výbojů. V úvodu je popsána základní charakteristika těchto výbojů při standardním sinusovém napájení. Vzhledem k rostoucímu využití výkonových …