Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 191 for “"Partial volume"”

  1. Partial Volume Quantification Using Magnetic Resonance Fingerprinting

    … voxel dimensions. However, in the presence of partial volumes, voxel-averaged properties are insufficient to quantitatively assess tissue characteristics such as the potential presence of pathology. It is therefore necessary to quantify both tissue properties and voxel composition. The …

    ohiolink Repository record for Partial Volume Quantification Using Magnetic Resonance Fingerprinting (opens in a new tab)

  2. Deep learning for partial volume correction in SPECT imaging

    … les simulations 2) la correction des effets de volume partiel (EVPs) des images TEMP par apprentissage profond.Les simulations Monte Carlo (MC) jouent un rôle essentiel en médecine nucléaire, notamment pour le calcul de dose, la conception de nouveaux systèmes TEMP et l'évaluation des …

    star-france Repository record for Deep learning for partial volume correction in SPECT imaging (opens in a new tab)

  3. Improved brain PET quantification using partial volume correction techniques

    … accuracy due to a phenomenon known as the partial volume effect (PVE). The effects are due to the limited spatial resolution of the scanner. Methods that correct for PVEs are known as partial volume correction (PVC) techniques and are either data-driven or make use of anatomical information …

    ucl Repository record for Improved brain PET quantification using partial volume correction techniques (opens in a new tab)

  4. Methodological improvements in quantitative MRI : Perfusion estimation and partial volume considerations

    … of perfusion MRI data, and ways to handle the partial volume issue.Constant delivery of oxygen and nutrients via the blood is vital for tissue viability. Perfusion MRI is designed to measure the properties of the local blood delivery, and perfusion images can be used as a marker for tissue …

    lund Repository record for Methodological improvements in quantitative MRI : Perfusion estimation and partial volume considerations (opens in a new tab)

  5. Improved Quantification of Arterial Spin Labelling Images using Partial Volume Correction Techniques

    … (ASL) MRI suffers from a phenomenon known as the partial volume effect (PVE), which causes a degradation in accuracy of quantitative perfusion estimates. The effect is caused by inadequate spatial resolution of the imaging system. Resolution of the system is determined by point spread function …

    ucl Repository record for Improved Quantification of Arterial Spin Labelling Images using Partial Volume Correction Techniques (opens in a new tab)

  6. Non-uniform resolution and partial volume recovery in tomographic image reconstruction methods

    Acquired data in tomographic imaging systems are subject to physical or detector based image degrading effects. These effects need to be considered and modeled in order to optimize resolution recovery. However, accurate modeling of the physics of data and acquisition processes still lead to an …

    ucl Repository record for Non-uniform resolution and partial volume recovery in tomographic image reconstruction methods (opens in a new tab)

  7. Partial-volume correction for high-resolution positron emission tomography using cortical surface information

    … due to the PET imaging process results in partial-volume effects (PVE) that obscure the true radiotracer distribution. Although several partial-volume correction algorithms exist, these frequently require severely limiting assumptions. We developed a new iterative deconvolution algorithm …

    mcgill Repository record for Partial-volume correction for high-resolution positron emission tomography using cortical surface information (opens in a new tab)

  8. Partial volume correction of 99mTc oncology SPECT imaging via case specific resolution estimation

    This project aimed to develop a practical method to compensate for the detrimental effect of limited spatial resolution in Tc-99m nuclear medicine oncology imaging. Correction for limited resolution is currently not routinely applied in clinical practice, limiting quantitative accuracy. Literature …

    ucl Repository record for Partial volume correction of 99mTc oncology SPECT imaging via case specific resolution estimation (opens in a new tab)

  9. Use of a non-stationary Markov random field in brain tissue partial volume segmentation

    This thesis describes a novel approach to partial volume segmentation of cerebrospinal fluid (CSF) in sulci of 3D magnetic resonance (MR) brain images that overcomes a key limitation of other techniques. The method is based upon previous work in that it uses a Markov random field (MRF) to encourage …

    mcgill Repository record for Use of a non-stationary Markov random field in brain tissue partial volume segmentation (opens in a new tab)

  10. Investigation and Correction for the Partial Volume Spill in Effects in Positron Emission Tomography

    Positron emission tomography (PET) imaging has a wide applicability in oncology, cardiology and neurology. However, a major drawback when imaging very active regions such as the bladder and the bone is the spill in effect, leading to inaccurate quantification and obscured visualisation of nearby …

    whiterose Repository record for Investigation and Correction for the Partial Volume Spill in Effects in Positron Emission Tomography (opens in a new tab)

  11. Improvements in the registration of multimodal medical imaging : application to intensity inhomogeneity and partial volume corrections

    … inhomogeneities (IIH) showing in MRI and the partial volume effect (PVE) attached to PET imaging. Reference methods exist for accurate image registration but their performance is severely deteriorated in situations involving little images Overlap. While several approaches to IIH and PVE …

    barcelona Repository record for Improvements in the registration of multimodal medical imaging : application to intensity inhomogeneity and partial volume corrections (opens in a new tab)

  12. ADDRESSING PARTIAL VOLUME ARTIFACTS WITH QUANTITATIVE COMPUTED TOMOGRAPHY-BASED FINITE ELEMENT MODELING OF THE HUMAN PROXIMAL TIBIA

    … of clinical CT systems, however, results in partial volume (PV) artifacts and low contrast between the cortical and trabecular bone, which adversely affect the accuracy of QCT-FE models. Using different cortical modeling and partial volume correction algorithms, the overall aim of this …

    sask Repository record for ADDRESSING PARTIAL VOLUME ARTIFACTS WITH QUANTITATIVE COMPUTED TOMOGRAPHY-BASED FINITE ELEMENT MODELING OF THE HUMAN PROXIMAL TIBIA (opens in a new tab)

  13. Automatic Bayesian segmentation of human facial tissue using 3D MR-CT fusion by incorporating models of measurement blurring, noise and partial volume

    … a prior helping to reduce noise as well as a partial volume model. Regularization based on isotropic and directional Markov Random Field priors are integrated to the algorithm and their effects on segmentation accuracy are investigated. The Bayesian model is solved iteratively yielding tissue …

    metu Repository record for Automatic Bayesian segmentation of human facial tissue using 3D MR-CT fusion by incorporating models of measurement blurring, noise and partial volume (opens in a new tab)

  14. A Medical Physics Chronicle In Three Acts: Machine Learning In Radiation Oncology; Designing RF Shim Coils In MRI; New Partial Volume Analysis In MRF.

    … imaging method. A key challenge in MRF are partial volume (PV) effects. Building on the seminal work into PV MRF, we propose a method based on density-based clustering, which is semi-automatic and interpretable. The brain tissue properties calculated by our method aligns closely with …

    ohiolink Repository record for A Medical Physics Chronicle In Three Acts: Machine Learning In Radiation Oncology; Designing RF Shim Coils In MRI; New Partial Volume Analysis In MRF. (opens in a new tab)

  15. PET Quantification for Assessing Tumour Response

    … may be compromised due to small activity and volume of the blood sample. The implementation of image-based simplified dynamic PET quantification in head and neck cancer patients requires partial volume correction due to small vessel sizes and limitted PET spatial resolution. The objective of …

    toronto-retro Repository record for PET Quantification for Assessing Tumour Response (opens in a new tab)

  16. A fuzzy clustering framework with neighbourhood constraints and quantitative analysis for segmentation of MRI images

    … include noise, intensity imhomogeneity and partial volume effect. Noise can dramatically degrade the performance of image segmentation algorithms. In order to remove the noise from MR images, a fuzzy filter is used and a modified spatial fuzzy c-means algorithm is developed to overcome the …

    nanyang Repository record for A fuzzy clustering framework with neighbourhood constraints and quantitative analysis for segmentation of MRI images (opens in a new tab)

Page 1 of 10