Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 44 for “"Partial volume effect"”
-
High resolution 3D diffusion tensor imaging for delineating neuronal architectures
… However, the intrinsic problem of DTI is the partial volume effect, which worsens when the structure of interest is complex with fine neuronal tracts. Although many techniques have been proposed to improve the resolution of DTI and hence reduce the partial volume effect, high isotropic …
-
Quantitative radionuclide imaging with a state-of-the-art preclinical PET/CT scanner
… of the major problems with quantification, the partial-volume effect, was studied. Partial-volume correction was applied using different methods: deconvolution post-reconstruction, modelling a point-spread function in the reconstruction and modelling the detector in the reconstruction. …
-
Identification and segmentation of the central sulcus from human brain MR image
… all sulci. The CS is the sulcus with the largest volume within the ROI. Together with the sulci, grey matter (GM) is included for the region growing in order to deal with the partial volume effect. The GM is removed through skeletonization. Experimental results are given.
-
Super-resolution in brain Diffusion Weighted Imaging (DWI)
… series of acquisition artifacts, among them the partial volume effect (PVE) that may completely alter the spatial resolution and therefore the visualization of microanatomical details. In this work, a new superresolution method will be presented, taking advantage of the redundant structural …
-
Segmentation of neuroanatomy in magnetic resonance images
… Resonance Imaging (MRI) is necessary for volume measurement, feature extraction and for the three-dimensional display of neuroanatomy. This thesis proposes several automated and semi-automated methods which offer considerable advantages over manual methods because of their lack of …
-
Improvements in the registration of multimodal medical imaging : application to intensity inhomogeneity and partial volume corrections
… inhomogeneities (IIH) showing in MRI and the partial volume effect (PVE) attached to PET imaging. Reference methods exist for accurate image registration but their performance is severely deteriorated in situations involving little images Overlap. While several approaches to IIH and PVE …
-
Methodological improvements in quantitative MRI : Perfusion estimation and partial volume considerations
… of perfusion MRI data, and ways to handle the partial volume issue.Constant delivery of oxygen and nutrients via the blood is vital for tissue viability. Perfusion MRI is designed to measure the properties of the local blood delivery, and perfusion images can be used as a marker for tissue …
-
Imaging and segmentation of bone in neurological magnetic resonance
… be helpful for the measurement of brain volume, especially small changes in voxel size, which is used in the quantitative assessment of changes in neurological diseases. Skull edge detection is made difficult due to the partial volume effect, strong edges between muscle and scalp, the …
-
Quantification of dopaminergic neurotransmission SPECT studies with 123 l-labelled radioligands
… stages, follow its progression and assess the effects of treatment strategies. SPECT images are affected by a number of effects that are inherent in the image formation: attenuation and scattering of photons, system response and partial volume effect. These effects degrade the contrast and …
-
Improved brain PET quantification using partial volume correction techniques
… accuracy due to a phenomenon known as the partial volume effect (PVE). The effects are due to the limited spatial resolution of the scanner. Methods that correct for PVEs are known as partial volume correction (PVC) techniques and are either data-driven or make use of anatomical information …
-
Multimodality Images Analysis for Photodynamic Therapy of Prostate Cancer in Mouse Models
… necrotic and viable regions, wherein, treatment effect was quantified by necrosis measurement. In order to follow up tumor response, a B-spline based surface registration algorithm was proposed to align the mouse body imaged at different time points, and so allowed tracking tumor response at …
-
Combining global and local information for the segmentation of MR images of the brain
… resonance imaging can provide high resolution volumetric images of the brain with exceptional soft tissue contrast. These factors allow the complex structure of the brain to be clearly visualised. This has lead to the development of quantitative methods to analyse neuroanatomical structures. In …
-
PET investigations in focal epilepsy
… with statistical parametric mapping (SPM), a volume-of-interest (VOI) approach with partial volume effect correction (PVC), or both. Findings: A method for automatical anatomical labelling and a probabilistic anatomical atlas were developed. 8/15 patients with HS had abnormalities of [¹¹C] …
-
Greedy techniques for magnetic resonance fingerprinting
… on spatial regularisation. • An extension to partial volumes and a greedy approximate projection algorithm. • An extension to Self-Calibration and Imaging. In quantitative Magnetic Resonance Imaging, traditional methods suffer from the so-called Partial Volume Effect (PVE) due to spatial …
-
Hybrid Kernelised Expectation Maximisation Reconstruction Algorithms for Quantitative Positron Emission Tomography
… techniques have been demonstrated to reduce partial volume effect (PVE), noise, and improve quantification, but, they have also been shown to rely on the accurate registration between the anatomical image and the PET image, otherwise they may suppress important PET information that may lead …
-
Multiresolution Image Analysis: Innovative applications for Positron Emission Tomography in clinical practice
… spatial resolution with resulting significant partial volume effect (PVE) that deteriorates the accuracy of the quantification of the physiological process under scrutiny. In this context, the use of multimodality imaging is very convenient to resolve this limitation. Using novel techniques …
-
Application of Independent Component Analysis (ICA) in Pharmacokinetic Modeling of Tumors Using Dynamic Contrast Enhanced (DCE)-MRI
… space due to heterogeneity of tumor vasculature, partial volume effect, and low resolution of DCE-MRI. Thus, it is approximated with an arterial input function (AIF) measured outside of the tissue of interest (TOI). Variations and error in calculation of AIF is one of the major sources of …
-
Bias and Variability In Image-Based Volumetric Yttrium-90 Dosimetry
… input images remain to be the weakest link in volumetric dosimetry. The objectives of this dissertation project were to improve image-based volumetric 90Y dose quantification using current commercially available systems and to determine its limitation (bias/variability). We have developed a …
-
Anatomically informed Bayesian inference for physiological imaging
… all aspects of physiological imaging. Notably, volumetric techniques of limited spatial resolution struggle to image complex anatomies such as the cerebral cortex. One consequence of this is the partial volume effect, which introduces bias or confound into parameter measurements derived from …
Page 1 of 3