Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 582 for “"Particle diameter"”

  1. Analysis of flow through cylindrical packed beds with small cylinder diameter to particle diameter ratios

    The wall effect is known to present difficulties when attempting to predict the pressure drop over randomly packed beds. The Nuclear Safety Standard Commission, "Kerntechnischer Auss-chuss" (KTA), made considerable efforts to develop an equation which predicts the pressure drop over cylindrical …

    nwu-za Repository record for Analysis of flow through cylindrical packed beds with small cylinder diameter to particle diameter ratios (opens in a new tab)

  2. Modeling the Effect of Particle Diameter and Density on Dispersion in an Axisymmetric Turbulent Jet

    Creating effective models predicting particle entrainment behavior within axisymmetric turbulent jets is of significant interest to many areas of study. Research into multiphase flows within turbulent structures has primarily focused on specific geometries for a target application, with little …

    vt Repository record for Modeling the Effect of Particle Diameter and Density on Dispersion in an Axisymmetric Turbulent Jet (opens in a new tab)

  3. Different methods for particle diameter determination of low density and high density lipoproteins-Comparison and evaluation

    … Small, dense HDL (High Density Lipoprotein) particles protect small dense LDL from oxidative stress. Technological advancements have introduced an array of techniques for measuring diameters of LDL and HDL as well as estimating overall particle heterogeneity. However, there is lack of …

    tamu Repository record for Different methods for particle diameter determination of low density and high density lipoproteins-Comparison and evaluation (opens in a new tab)

  4. The effect of particle diameter and taper angle on the hydrodynamics of a liquid-solid tapered fluidized bed

    … 0.5°, 1.5°) in order to determine the effect of particle size and taper angle on the hydrodynamics of a tapered liquid-solid fluidized bed. Dispersion coefficients were measured using the imperfect pulse method of Michelsen and Ostergaard (1970) and void fractions were measured locally using an …

    utk-theses Repository record for The effect of particle diameter and taper angle on the hydrodynamics of a liquid-solid tapered fluidized bed (opens in a new tab)

  5. Laboratory scale investigations into the influence of particle diameter on colloid transport in highly weathered and fractured shale saprolite

    … was performed using 0.5, 1.7 and 4.25 μm diameter microspheres in a .005 M CaBr<sub>2</sub> solution. Microsphere breakthrough curves for both experiments exhibited a common pattern of rapid initial breakthrough, followed by a concentration "plateau". which was up to four orders of …

    ut-knoxville Repository record for Laboratory scale investigations into the influence of particle diameter on colloid transport in highly weathered and fractured shale saprolite (opens in a new tab)

  6. An Optical Diagnostic for Instantaneous Measurements of Soot Volume Fraction, Primary Particle Diameter and Mean Aggregate Radius of Gyration in Large Turbulent Flames

    … of the soot volume fraction, soot primary particle diameter, and soot mean aggregate radius of gyration in large, turbulent, non-premixed flames. A combination of auto compensating laser induced incandescence and elastic light scattering was used to make the measurements. The produced …

    carleton Repository record for An Optical Diagnostic for Instantaneous Measurements of Soot Volume Fraction, Primary Particle Diameter and Mean Aggregate Radius of Gyration in Large Turbulent Flames (opens in a new tab)

  7. The relation of bed depth, particle density, and particle size to the local coefficients of heat transfer of internally-heated fluidized beds of solids

    … coefficients of heat transfer with bed depth, particle density, and particle size were studied using a pyrex pipe four inches in diameter as the fluidizing vessel. The fluidized solids investigated were aerocat cracking catalyst, having a geometric-mean particle diameter of 0.00262 inch and an …

    vt Repository record for The relation of bed depth, particle density, and particle size to the local coefficients of heat transfer of internally-heated fluidized beds of solids (opens in a new tab)

  8. Investigation of hydrodynamic scaling relationships in shallow spouted beds

    … for shallow spouted beds of high-density particles were characterized in terms of three features: minimum spouting velocity, overall bed pressure drop at minimum spouting velocity; and fountain height. Spouted bed literature is sparse for shallow beds (static particle depth to bed diameter …

    utk-theses Repository record for Investigation of hydrodynamic scaling relationships in shallow spouted beds (opens in a new tab)

  9. Effect of particle size and particle size distribution on the burning rate of barium chromate-boron pyrotechnic delay compositions

    … is shown to be related to the 10 percent particle size point on the particle size distribution curve (particle size vs. percent greater than size) for either of the components. The burning rate is also shown to be inversely proportional to the 10 percent point of the barium chromate; and …

    njit Repository record for Effect of particle size and particle size distribution on the burning rate of barium chromate-boron pyrotechnic delay compositions (opens in a new tab)

  10. Pressure Drop in a Pebble Bed Reactor

    … can be explained by using different bed-to-particle diameter ratios. Four different bed-to-particle ratios were used in these experiments (D/dp = 19, 9.5, 6.33 and 3.65). A comparison is made between the predictions by a number of empirical correlations including the Ergun equation (1952) …

    tamu Repository record for Pressure Drop in a Pebble Bed Reactor (opens in a new tab)

  11. The Effect of Water Droplet Oscillations on the Scavenging Efficiency of Micron Sized Particles

    … wake affect the scavenging efficiency, E, of particles. However, no conclusive results have been presented on the effect these phenomena might have on particle scavenging. To address this need, experiments were conducted using oscillating water drops and water drops damped by the addition of …

    clemson Repository record for The Effect of Water Droplet Oscillations on the Scavenging Efficiency of Micron Sized Particles (opens in a new tab)

  12. Experimental Investigation of Solid and Liquid Aerosol Transport in a Horizontal Square Channel

    … study the transport of solid and liquid aerosol particles which represented aerosolized fission products in a nuclear reactor. We measured the flow field, free-stream concentration, and surface deposition of solid/liquid aerosols flowing in a horizontal square channel with Reynolds number of …

    tamu Repository record for Experimental Investigation of Solid and Liquid Aerosol Transport in a Horizontal Square Channel (opens in a new tab)

  13. Effect of particle size on sand deposition in single-phase and multi-phase pipelines.

    … This study investigates the effect both of sand particle diameter and concentration on minimum transport conditions in single phase and multiphase horizontal pipelines through experimental methods. This study defines the minimum transport condition (MTC) for sand grains under stratified two-phase …

    cranfield Repository record for Effect of particle size on sand deposition in single-phase and multi-phase pipelines. (opens in a new tab)

  14. Adhesion of particles on indoor flooring materials

    … of the adhesive forces between spherical particles of four different diameters and two selected flooring materials under different air velocities. Previous theoretical work and experiments described in the literature tended to be conducted with idealized surfaces, and therefore have …

    texas Repository record for Adhesion of particles on indoor flooring materials (opens in a new tab)

  15. Feasibility of the use of capillary electrophoresis for the study of vldl assembly intermediates

    … of hens, roosters, and estrogen treated rosters. Particle diameter of first step particles, as determined by dynamic laser light scattering, was decreased from an average diameter of 31.5 nm in untreated birds, to 16.1 nm 12 hours after estrogen treatment. Effects of estrogen waned after 24 hours …

    tamu Repository record for Feasibility of the use of capillary electrophoresis for the study of vldl assembly intermediates (opens in a new tab)

  16. Corrosion Dynamics of Cobalt-Chromium Alloy F-75 Powder

    … Four powder sizes (44, 74, 105, and 420 µm diameter) were subjected to Hank’s Balanced Salt Solution (HBSS) for a 42 day immersion test within an incubating shaker set at 37°C. Samples were removed periodically and analyzed for cobalt and chromium content using Inductive Coupled Plasma – …

    calpoly Repository record for Corrosion Dynamics of Cobalt-Chromium Alloy F-75 Powder (opens in a new tab)

  17. Two-Phase Flow in Circular Secondary Sedimentation Tanks

    … a turbulent jet, was over-predicted. The mean particle diameter in the model was found by comparing the numerical predictions with experimental data. The particle diameter was between 100 to 190 μm for the secondary clarifiers, which was in agreement with the experimental data in the …

    cranfield Repository record for Two-Phase Flow in Circular Secondary Sedimentation Tanks (opens in a new tab)

Page 1 of 30