Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"Passive cavitation detection"”

  1. Effects of Histotripsy on Bacterial Viability in Suspension

    … the bactericidal effects of histotripsy, a cavitation-based focused ultrasound therapy, on two bacteria in suspension namely Escherichia coli and Staphylococcus aureus, for potential application in abscess treatment. Abscesses are localized encapsulated collections of pus and bacteria that …

    washington Repository record for Effects of Histotripsy on Bacterial Viability in Suspension (opens in a new tab)

  2. Putting cavitation to work: applications of strongly collapsing bubbles

    … are often conveniently captured by the word ‘cavitation’, can produce profound effects in the medium and mechanisms in which they are produced. The word ‘cavitation’ then implies bubble activity consistent with significant growth followed by strong detectable collapse. Such a definition is …

    bu Repository record for Putting cavitation to work: applications of strongly collapsing bubbles (opens in a new tab)

  3. Interaction of mechanical and thermal lesions induced by high intensity focused ultrasound (HIFU)

    … histotripsy. The characteristics of bubble cavitation by passive cavitation detection (PCD) for the inertial and stable cavitation and temperature elevation by a thermocouple were measured during the therapeutic procedure. Lesion would vary from a mechanical erosion in the shape of a “squid” …

    nanyang Repository record for Interaction of mechanical and thermal lesions induced by high intensity focused ultrasound (HIFU) (opens in a new tab)

  4. Use of high intensity focused ultrasound to destroy subcutaneous fat tissue

    … effectively and non-invasively. Based on initial cavitation and temperature measurements performed ex vivo in excised porcine fat at four different frequencies (0.5, 1.1, 1.6 & 3.4MHz) over a range of pressure amplitudes and exposure durations, it was concluded that 0.5MHz is the optimal frequency …

    oxford Repository record for Use of high intensity focused ultrasound to destroy subcutaneous fat tissue (opens in a new tab)

  5. Developing an Ultrasound–Responsive Lipid Nanoparticle–Microbubble Conjugate via Click Chemistry for mRNA Delivery

    … mRNA delivery. Acoustic characterisation using passive cavitation detection (PCD) revealed that LNP–loaded MBs exhibited reduced cavitation activity compared with unconjugated MBs under two acoustic pressures tested (0.4 MPa and 0.8 MPa, peak to peak), indicating that particle conjugation alters …

    ucl Repository record for Developing an Ultrasound–Responsive Lipid Nanoparticle–Microbubble Conjugate via Click Chemistry for mRNA Delivery (opens in a new tab)

  6. Ultrasonic Histotripsy for Cell Therapy

    … new cell therapy. A high-speed camera with a passive cavitation detection (PCD) system were used to observe the dynamics of bubbles produced in optically transparent tissue phantoms exposed to HIFU fields. Numerical studies on the bubble dynamics and both ex- and in vivo liver experiments were …

    ucl Repository record for Ultrasonic Histotripsy for Cell Therapy (opens in a new tab)

  7. Ultrasound cavitation agent mediated gastrointestinal drug delivery

    … aims to explore the feasibility of ultrasound cavitation agent mediat-ed gastrointestinal drug delivery (UCAMGIDD) in pursuit of the goal to deliver biopharmaceu-ticals via the oral route. A less thermogenic and faster manufacturing method for lipid-shelled microbubbles was optimised with …

    oxford Repository record for Ultrasound cavitation agent mediated gastrointestinal drug delivery (opens in a new tab) Restricted access

  8. A Microscopy-Based Investigation of Microbubble Mediated Antivascular Ultrasound

    … using a combination of microscopy techniques and passive cavitation detection. Two-photon microscopy was employed to assess AVUS in a window chamber tumor model. Flow shutdown preferentially occurred in smaller tumor microvessels, with the incidence and impacted vessel calibers increasing with …

    toronto-retro Repository record for A Microscopy-Based Investigation of Microbubble Mediated Antivascular Ultrasound (opens in a new tab)

  9. High-intensity focused ultrasound (HIFU) induced hyperechoic regions for the ultrasound guidance of HIFU therapy

    … of this dissertation were to: (1) confirm if cavitation is involved in the appearance of a hyperechoic region; (2) determine if there is a relationship between temperature change and the formation of a hyperechoic region; and (3) determine if a hyperechoic region can be used for targeting of …

    washington Repository record for High-intensity focused ultrasound (HIFU) induced hyperechoic regions for the ultrasound guidance of HIFU therapy (opens in a new tab)

  10. Cavitation monitoring and spatial mapping for pulsed high-intensity focused ultrasound enhanced drug delivery

    … caused by ultrasound-induced bubble activity- cavitation. Although cavitation can be beneficial, the violent collapsing of bubbles may cause undesired tissue damage. Therefore, it is very important to monitor cavitation activity during pHIFU treatments and know the ultrasound pressure levels …

    washington Repository record for Cavitation monitoring and spatial mapping for pulsed high-intensity focused ultrasound enhanced drug delivery (opens in a new tab)

  11. Relationship between loss of echogenicity and cavitation emissions from echogenic liposomes insonified by spectral Doppler ultrasound

    … agents (UCAs) being developed for the early detection and treatment of cardiovascular disease. Stability of the echogenicity of ELIP in physiologic conditions is crucial to their successful translation to clinical use. The stability of ELIP echogenicity was determined in vitro under …

    ohiolink Repository record for Relationship between loss of echogenicity and cavitation emissions from echogenic liposomes insonified by spectral Doppler ultrasound (opens in a new tab)

  12. Implementing hybrid ultrasound modalities for high-intensity focused ultrasound monitoring

    … and implement its whole journal monitoring via passive acoustic mapping (PAM) and interlaced high frame rate B-mode. For the dual ultrasound modalities, efforts have been devoted to advanced algorithms with computation efficacy to improve the contrast to noise ratio for hyperechogenicity …

    whiterose Repository record for Implementing hybrid ultrasound modalities for high-intensity focused ultrasound monitoring (opens in a new tab)

  13. High intensity focused ultrasound (HIFU) ablation using the frequency sweeping excitation

    … was further evaluated for the enhanced bubble cavitation. Both gel phantom and ex vivo studies showed that with a proper selection of the frequency sweep range and sweep time, a 50% enlargement of lesion size could be achieved. Analysis of the bubble cavitation signal captured by passive …

    nanyang Repository record for High intensity focused ultrasound (HIFU) ablation using the frequency sweeping excitation (opens in a new tab)

  14. A sonochemical approach for sustainable hydrogen and syngas generation

    … advantages through the phenomenon of acoustic cavitation, which generates localised zones of extreme temperature and pressure capable of initiating reactions that are otherwise difficult to achieve. This thesis explores the development of a sonochemically efficient reactor and its application …

    oxford Repository record for A sonochemical approach for sustainable hydrogen and syngas generation (opens in a new tab)

  15. Passive Imaging and Measurements of Acoustic Cavitation during Ultrasound Ablation

    <p>Cavitation is known to affect therapeutic ultrasound applications such as tissue ablation, where it may complicate heat deposition and make treatment control difficult. In this thesis, acoustic emissions from cavitating bubbles are measured and imaged to serve as indicators of thermal ablation …

    ohiolink Repository record for Passive Imaging and Measurements of Acoustic Cavitation during Ultrasound Ablation (opens in a new tab)