Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 10 of 10 for “"Passive cavitation imaging"”
-
Passive Imaging and Measurements of Acoustic Cavitation during Ultrasound Ablation
<p>Cavitation is known to affect therapeutic ultrasound applications such as tissue ablation, where it may complicate heat deposition and make treatment control difficult. In this thesis, acoustic emissions from cavitating bubbles are measured and imaged to serve as indicators of thermal ablation …
-
Putting cavitation to work: applications of strongly collapsing bubbles
… are often conveniently captured by the word ‘cavitation’, can produce profound effects in the medium and mechanisms in which they are produced. The word ‘cavitation’ then implies bubble activity consistent with significant growth followed by strong detectable collapse. Such a definition is …
-
Quantitative Assessment of Cavitation from DEFINITYr and DEFINITY RTr and Insonified by a Repaired Therapeutic Array
… and DEFINITY RT® microbubbles and to quantify cavitation activity nucleated by the agents during infusion through a multi sideport catheter in a flow phantom mimicking the human femoral vein exposed to 1.5 MHz therapeutic pulsed ultrasound. Echo contrast agent size distributions were measured …
-
Histotripsy as an Adjuvant Therapy for Deep Vein Thrombosis
… differences between acute and chronic thrombi. Imaging techniques were also tested to gauge sample response to lytic therapy. We found thrombi older than 7 days have substantial changes in the extracellular structure compared younger thrombi (< 7 days old). A positive trend was observed between …
-
Histotripsy as an Adjuvant Therapy for Deep Vein Thrombosis
… differences between acute and chronic thrombi. Imaging techniques were also tested to gauge sample response to lytic therapy. We found thrombi older than 7 days have substantial changes in the extracellular structure compared younger thrombi (< 7 days old). A positive trend was observed between …
-
Relationship between loss of echogenicity and cavitation emissions from echogenic liposomes insonified by spectral Doppler ultrasound
… agents (UCAs) have the potential to nucleate cavitation and promote both beneficial and deleterious bioeffects in vivo. Previous studies have elucidated the pressure amplitude threshold for rapid loss of echogenicity due to UCA fragmentation as a function of pulse duration and pulse repetition …
-
Role of Cavitation during Bulk ultrasound Ablation: Ex vivo and In vivo Studies
… was used to suppress cavitation and tissue vaporization in the ex vivo studies.Ex vivo bovine liver was ablated with unfocused ultrasound (3.1 MHz or 4.8 MHz) at 31 W/cm2for 10 or 20 minutes. A passive cavitation detector (PCD) was used to record acoustic …
-
Therapeutic Ultrasound: Improved Image Guidance and Combinatorial Treatments for Recurrent Prostate Cancer
… methods currently available. Improved imaging metrics are needed to better plan, treat, and evaluate thermal ultrasound ablation and histotripsy, as well as to quantify the release of drugs or generation of ROS during SDT. The first aim of this dissertation examined a novel theranostic …
-
Therapeutic Ultrasound: Improved Image Guidance and Combinatorial Treatments for Recurrent Prostate Cancer
… methods currently available. Improved imaging metrics are needed to better plan, treat, and evaluate thermal ultrasound ablation and histotripsy, as well as to quantify the release of drugs or generation of ROS during SDT. The first aim of this dissertation examined a novel theranostic …
-
Contributions à l’imagerie passive de la cavitation ultrasonore : formation de voies adaptatives en 3D et extension spatiale de nuages de bulles
L’imagerie passive s’appuie sur des algorithmes de formation de voie qui nécessitent des sondes de grande ouverture pour offrir de bonnes résolutions axiales ; or, en imagerie passive 3D, les sondes matricielles actuellement commercialisées ne vérifient pas cette contrainte. De plus, ces sondes …