Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 4 of 4 for “"Passive chilled beam"”

  1. The Effect of Thermal Load Configurations on Passive Chilled Beam Performance

    … heat source configurations on the performance of passive chilled beams. Experiments in a thermally controlled test room were conducted using thermal manikins as heat sources cooled with a 0.6 m by 2.4 m beam. The thermal manikins were arranged in a symmetric and an asymmetric configuration and …

    tamu Repository record for The Effect of Thermal Load Configurations on Passive Chilled Beam Performance (opens in a new tab)

  2. Evaluating the performance of passive chilled beams with respect to energy efficiency and thermal comfort

    Existing modeling approaches for passive chilled beams determined from tests on individual chilled beams in a laboratory are not adequate for assessing overall energy usage and occupant comfort within building simulation programs. In addition, design guidelines for passive chilled beam systems are …

    purdue-thes Repository record for Evaluating the performance of passive chilled beams with respect to energy efficiency and thermal comfort (opens in a new tab)

  3. Modeling and Control of Passive Chilled Beams with Underfloor Air Distribution of Ventilation in Office Buildings in Humid Climates

    … and comfort conditions associated with passive chilled beams for office buildings in a humid climate and to develop a method for the modeling of passive chilled beams with a ventilation system and underfloor air distribution (UFAD). For the analysis, a 606,900 ft2 commercial office …

    tamu Repository record for Modeling and Control of Passive Chilled Beams with Underfloor Air Distribution of Ventilation in Office Buildings in Humid Climates (opens in a new tab)

  4. Análise computacional da distribuição de ar em recintos climatizados por métodos de estratificação de temperatura

    … displacement ventilation. The efficiency of a passive chilled beam is also evaluated as a complementary method for removing sensible heat. It is proposed to evaluate, from results obtained from computational fluid dynamics (CFD), the parameters of thermal comfort in the occupied zone and the …

    brazil-uerj Repository record for Análise computacional da distribuição de ar em recintos climatizados por métodos de estratificação de temperatura (opens in a new tab)