Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 29 for “"Passive mixing"”

  1. Passive mixing on microfluidic devices via dielectric elastomer actuation

    Mixing is an essential process to many areas of science for example it is important in studying chemical reaction kinetics, chemical synthesis, DNA hybridization and PCR amplification. Mixing on the macroscale level is readily achieved through convection. Rapid mixing on microchips however, is …

    ksu Repository record for Passive mixing on microfluidic devices via dielectric elastomer actuation (opens in a new tab)

  2. Computational fluid dynamics (CFD) simulations applied to the design of passive mixing microfluidic systems

    Las simulaciones de dinámica de fluidos computacional de microfluidos y microsistemas permiten diseñar y probar rápidamente el rendimiento de múltiples prototipos identificando las variables que más impactan en la eficiencia del dispositivo para una tarea en particular. Este trabajo tuvo como …

    uniandes Repository record for Computational fluid dynamics (CFD) simulations applied to the design of passive mixing microfluidic systems (opens in a new tab)

  3. Active and Passive Mixing for Immiscible Liquid-Liquid Systems: A Performance Evaluation of Novel Micro-Reactors

    … use continuous flow. In this thesis, elements of passive and active mixing are investigated for the application of immiscible liquid-liquid systems. In the first study, the effects of geometrical arrangements of a residence time between mixing units on the interphase mass transfer rates are …

    ottawa-retro Repository record for Active and Passive Mixing for Immiscible Liquid-Liquid Systems: A Performance Evaluation of Novel Micro-Reactors (opens in a new tab)

  4. Effect of Storage Tank Mixing on Water Quality

    … and operation of the storage tanks affect their mixing characteristics which affect the water quality. Poor mixing can lead to stratification in the tanks, which can lead to low chlorine residual causing microbial growth and nitrification. This thesis presents the results of the study of seven …

    sdstate Repository record for Effect of Storage Tank Mixing on Water Quality (opens in a new tab)

  5. Computational Analysis of Mixing in Microchannels

    … biomedical and chemical industries, etc. Mixing is inevitable for the analysis of trace chemicals, drugs, bio-molecules, fluidic controls in microfluidics, etc. Such miniaturized microfluidics had already proven better over bulky instrumentations, because of time and transportation …

    ohiolink Repository record for Computational Analysis of Mixing in Microchannels (opens in a new tab)

  6. A Theoretical, Numerical, and Experimental Study of Trapped Droplet Coalescence and Mixing, Passively and Under Electric Field

    Passive and electrically active coalescence and mixing of pairs of trapped squeezed nanodroplets were studied in this work. PDMS-glass microfluidic devices were designed and fabricated using multilevel photolithography technique. Flow-focusing method was used to generate nanoliter droplets of died …

    ucf Repository record for A Theoretical, Numerical, and Experimental Study of Trapped Droplet Coalescence and Mixing, Passively and Under Electric Field (opens in a new tab)

  7. High Frequency Generation from Carbon Nanotube Field Effect Transistors Used as Passive Mixers

    … using a Taylor expansion. For the high frequency mixing experiments, two input voltages of different frequencies are sourced on the gate of the devices without any device biasing. The input frequencies are limited to 100 kHz to 40 GHz by the signal generators used. The nonlinearities of the …

    maryland Repository record for High Frequency Generation from Carbon Nanotube Field Effect Transistors Used as Passive Mixers (opens in a new tab)

  8. A computational study on mixing of two-phase flow in microchannels

    <p>The passive mixing of water and alcohol, as two fluids with different densities, is carried out computationally in three-dimensional microchannels. Four designs of microchannels are considered to investigate the efficiency of mixing for Reynolds numbers ranging between 6 and 96. In a …

    iastate Repository record for A computational study on mixing of two-phase flow in microchannels (opens in a new tab)

  9. Broadband microwave diode mixer design and implementation

    … the design and implementation of two passive mixing circuits using Schottky barrier diodes at microwave frequencies. The first circuit is a broadband mixer which operates between 2 GHz and 18 GHz for RF/LO frequency with an average conversion loss of 7 dB. It provides LO-RF and RF-IF …

    metu Repository record for Broadband microwave diode mixer design and implementation (opens in a new tab)

  10. A MEMS based Coulter counter for cell sizing

    … device is based on three important phenomena: 1) Passive mixing of the reagents, 2) Dielectrophoretic focusing of the cells and 3) Electrical impedance based sensing mechanism. This device improves upon existing macro-scale Coulter counter technology by allowing extremely small sample sizes (101 …

    missouri Repository record for A MEMS based Coulter counter for cell sizing (opens in a new tab)

  11. Simulation and Experimental Investigation of Fluid Mixing Enhancement with Orifice Plate

    Current experimental and simulation fluid mixing studies aim to increase mixing efficiency and incorporate various measurement methods to quantify mixing. In this thesis, comprehensive simulation and experimental studies were carried out to investigate the effects of an orifice plate on mixing. …

    usf Repository record for Simulation and Experimental Investigation of Fluid Mixing Enhancement with Orifice Plate (opens in a new tab)

  12. Geothermal heat for remote acid mine drainage remediation: a laboratory and modelling study

    … industry and the government for these sites is a passive system that utilizes locally available and cheap material. Often the geothermal gradient available in mines, or the corresponding geothermal reservoir conditions proximal to the mine, is a viable heat energy source that can provide …

    colo-mines Repository record for Geothermal heat for remote acid mine drainage remediation: a laboratory and modelling study (opens in a new tab)

  13. 3D printed microfluidic device for point-of-care anemia diagnosis

    … fabricate a 3D printed, low cost microfluidic mixing chip that could be used for the diagnosis of anemia. Microfluidic mixing chips use capillary flow to move fluids without the aid of external power. With new developments in 3D printing technology, microfluidic devices can be fabricated …

    ksu Repository record for 3D printed microfluidic device for point-of-care anemia diagnosis (opens in a new tab)

  14. Synthesis and characterization of tetracycline loaded chitosan nanoparticles using a microfluidic method for biofilm suppression /

    … consisted of a serpentine channel and three mixing chambers that enhanced passive mixing under laminar flow. Nine different nanoparticles were synthesised and analysed using dynamic light scattering (DLS). The optimized nanoparticles were additionally characterized using scanning electron …

    vilnius Repository record for Synthesis and characterization of tetracycline loaded chitosan nanoparticles using a microfluidic method for biofilm suppression / (opens in a new tab)

  15. Enhanced Biomolecular Binding to Beads on a Digital Microfluidic Device

    … standard microfabrication procedures to compare passive mixing, active mixing on electrode arrays and local bead actuation on an integrated current-wire electrode, whereby current is sequenced through copper wires fabricated on the electrode to generate magnetic-fields on-chip that cause the …

    duke Repository record for Enhanced Biomolecular Binding to Beads on a Digital Microfluidic Device (opens in a new tab)

  16. MEMS Coulter counter for dynamic impedance measurement of time sensitive cells

    … of time and cellular volumetric changes after mixing isolated cell populations with different extracellular media within 0.2 second from the start of mixing. The novelty of this design is the use of multi-electrodes with vertical sidewalls to enable the measurements of time sensitive cells with …

    missouri Repository record for MEMS Coulter counter for dynamic impedance measurement of time sensitive cells (opens in a new tab)

  17. HIGH FREQUENCY GENERATION BASED ON CARBON NANOTUBE FIELD-EFFECT TRANSISTORS

    … gate controlled radio frequency mixers. Two-tone mixing measurement shows clearly that intermodulation terms in the output spectrum are strong in ampibolar regions and suppressed to noise floor in the linear regions. We further perform passive mixing (no source/drain voltage applied) in higher …

    maryland Repository record for HIGH FREQUENCY GENERATION BASED ON CARBON NANOTUBE FIELD-EFFECT TRANSISTORS (opens in a new tab)

  18. Development of Lattice-Augmented Fuels for Hybrid Rocket Applications

    … of improving the combustion efficiency. A passive mixing device located in the combustion chamber was used to improve the combustion efficiency of the wax-based fuel by over 40%. Finally, lattice-augmented fuels were demonstrated in-flight during a series of sounding rocket flights which …

    calgary Repository record for Development of Lattice-Augmented Fuels for Hybrid Rocket Applications (opens in a new tab)

  19. Characterization of Paraffin-Based Lattice-augmented Hybrid Rocket Fuel for Sloughing Mitigation

    … stratification, prior studies introduced passive mixing devices, such as protrusions, to enhance turbulent mixing. This study experimentally investigated various protrusion materials and their effect on fuel regression. Among the materials tested, silicon carbide (SiC) and mullite …

    calgary Repository record for Characterization of Paraffin-Based Lattice-augmented Hybrid Rocket Fuel for Sloughing Mitigation (opens in a new tab)

Page 1 of 2