Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 48 for “"Patch test"”.

  1. Contact allergy to fragrances with a focus on oak moss absolute

    … that they may evaporate from petrolatum patch test preparations applied in test chambers. In the first two papers included in this thesis the aims were to i) to investigate the stability of fragrance preparations in petrolatum when applied in patch test chambers, and ii) to investigate …

    lund Repository record for Contact allergy to fragrances with a focus on oak moss absolute (opens in a new tab) Download PDF for Contact allergy to fragrances with a focus on oak moss absolute (opens in a new tab)

  2. Contact allergy to fragrances. With a focus on hydroperoxides of linalool and hydroperoxides of limonene

    Patch testing with fragrance allergens has been performed for over half a century, and the protocol has been continually developed and standardised. Fragrance mixes I and II and Myroxylon pereirae resin are commonly used as screening fragrance allergens in patch testing.During the past few decades, …

    lund Repository record for Contact allergy to fragrances. With a focus on hydroperoxides of linalool and hydroperoxides of limonene (opens in a new tab) Download PDF for Contact allergy to fragrances. With a focus on hydroperoxides of linalool and hydroperoxides of limonene (opens in a new tab)

  3. An overview on contact allergy to acrylates /

    … of this narrative review was to compile the latest scientific information concerning the immunopathogenesis, clinical manifestations, diagnostic modalities, epidemiology, and treatment of acrylate-induced allergic contact dermatitis, especially focusing on occupational, consumer, and medical …

    vilnius Repository record for An overview on contact allergy to acrylates / (opens in a new tab)

  4. Patch testing with palladium and aluminium, epidemiological and experimental studies

    … the importance of the metal aluminium used in test chamber systems and the effect of aluminium chloride (Al-Cl) in patch test preparations. A retrospective study (study I), with 18,306 patch test results obtained from 1995-2016 showed that the prevalence of contact allergy to palladium is …

    lund Repository record for Patch testing with palladium and aluminium, epidemiological and experimental studies (opens in a new tab) Download PDF for Patch testing with palladium and aluminium, epidemiological and experimental studies (opens in a new tab)

  5. <i>Assessment of High-Order Serendipity and Lagrangian Quadrilateral Membrane Elements</i>

    … This assessment includes an evaluation of the patch test, an element eigenvalue test to detect any zero-energy modes, and selected plane stress problems. The effects of using both full and reduced numerical integration procedures and optimum locations for stress recovery are discussed. All …

    odu Repository record for <i>Assessment of High-Order Serendipity and Lagrangian Quadrilateral Membrane Elements</i> (opens in a new tab)

  6. Research on nickel alloy sensitivity

    … to be sensitive to nickel. Uses a standard patch test to identify sensitive subjects

    adelaide Repository record for Research on nickel alloy sensitivity (opens in a new tab)

  7. Διασταυρούμενες αντιδράσεις ευαισθητοποίησης στις χρωστικές τριχών στον ελληνικό πληθυσμό

    … allergens, and the diagnostic value of extended patch testing in a Greek patient population.Materials and Methods: This retrospective observational study included 666 patients with suspected hair dye-related allergic contact dermatitis who underwent patch testing at the Patch Test Clinic of the …

    greece Repository record for Διασταυρούμενες αντιδράσεις ευαισθητοποίησης στις χρωστικές τριχών στον ελληνικό πληθυσμό (opens in a new tab)

  8. The UTexas Seal Coat Design Method using 3D laser technology

    … techniques and analyzes the variance of the sand patch test. The findings indicate that the sand patch test is not a reliable estimator of the volume of voids in the surface texture, which negatively affects the calculation of the binder application rate. The study recommends an algorithm that …

    texas Repository record for The UTexas Seal Coat Design Method using 3D laser technology (opens in a new tab)

  9. Contact allergy to formaldehyde. Diagnosis and clinical relevance.

    … allergy to formaldehyde using the baseline patch test series; ii) to determine the optimal patch test concentration and dose for formaldehyde; iii) to study the clinical relevance of contact allergy to formaldehyde detected by formaldehyde 2.0% (0.60 mg/cm2) but not by formaldehyde 1.0% …

    lund Repository record for Contact allergy to formaldehyde. Diagnosis and clinical relevance. (opens in a new tab) Download PDF for Contact allergy to formaldehyde. Diagnosis and clinical relevance. (opens in a new tab)

  10. Contact allergy to textile dyes. Clinical and experimental studies on disperse azo dyes

    … those disperse dyes that are now present in test series are actually used in textile dyeing today. The aim of this thesis was A) to evaluate the significance of the impurities found in the commercial dyes Disperse Orange 1 and Disperse Yellow 3 and their potential metabolites from azo …

    lund Repository record for Contact allergy to textile dyes. Clinical and experimental studies on disperse azo dyes (opens in a new tab) Download PDF for Contact allergy to textile dyes. Clinical and experimental studies on disperse azo dyes (opens in a new tab)

  11. Experimental and Clinical Studies on Contact Allergy to Diphenylmethane-4,4′-diisocyanate and Related Substances

    … due to co-exposure or possible cross-reactivity. Patch test preparations of 4,4′-MDI have been shown to contain only fractions of what is stated. Concentrations of 4,4′-MDI in test preparations decrease rapidly. The aim of the first two papers included in this thesis was to study the dermal uptake …

    lund Repository record for Experimental and Clinical Studies on Contact Allergy to Diphenylmethane-4,4′-diisocyanate and Related Substances (opens in a new tab) Download PDF for Experimental and Clinical Studies on Contact Allergy to Diphenylmethane-4,4′-diisocyanate and Related Substances (opens in a new tab)

  12. A scaled boundary finite element based node-to-node scheme for contact problems.

    … Their implementations, however, either fail the patch test or require sophisticated algorithms and techniques. This thesis presents a novel NTN contact scheme based on the scaled boundary finite element method (SBFEM). Nonmatching meshes can be converted to matching ones through polytope elements …

    unsw Repository record for A scaled boundary finite element based node-to-node scheme for contact problems. (opens in a new tab)

  13. Contact Allergy to Textile Dyes - Clinical and Chemical Studies on Disperse Dyes

    … rubber substances, and to ascertain whether patch testing with the dye mix was equivalent to testing with the separate ingredients at the concentrations used in the mix. Furthermore, the purity of the 8 disperse dyes used for patch testing at various dermatology departments and the …

    lund Repository record for Contact Allergy to Textile Dyes - Clinical and Chemical Studies on Disperse Dyes (opens in a new tab) Download PDF for Contact Allergy to Textile Dyes - Clinical and Chemical Studies on Disperse Dyes (opens in a new tab)

  14. Chip Seals for Asphalt Concrete Pavements: A Proposed Emulsion Residue Specification and Existing Pavement Texture Evaluation

    … included the following tasks: investigation of a testing and grading system for grading asphalt binder residues from chip seal emulsions; and investigation of texture measurement methods for assessing existing pavement macrotexture before a chip seal is placed. The performance graded (PG) asphalt …

    tamu Repository record for Chip Seals for Asphalt Concrete Pavements: A Proposed Emulsion Residue Specification and Existing Pavement Texture Evaluation (opens in a new tab)

  15. Strongly orthotropic continuum mechanics

    … objectivity, material frame-indifference, patch test satisfaction, and agreement between the subsequent Material Principal Co-rotation and P–I–C decomposition methods that produce the intermediary stress/strain fields. The encompassing theory has wide applicability owing to its fundamental …

    unsw Repository record for Strongly orthotropic continuum mechanics (opens in a new tab)

  16. Στατιστικά μοντέλα φασματογραφίας ηλεκτρικής εμπέδησης και φωτονικής σε επαληθευμένα δερματολογικά διαγνωστικά δεδομένα

    … of life. Its diagnosis is based on epicutaneous patch testing, which represents the reference standard for the identification of causative allergens. However, interpretation of patch test reactions relies on the International Contact Dermatitis Research Group (ICDRG) scoring system, an …

    greece Repository record for Στατιστικά μοντέλα φασματογραφίας ηλεκτρικής εμπέδησης και φωτονικής σε επαληθευμένα δερματολογικά διαγνωστικά δεδομένα (opens in a new tab)

  17. Penetration of harmful substances into the skin: polycyclic aromatic hydrocarbons and metal allergens

    … are, contrary to palladium, part of the standard patch test used as diagnostic tool to detect contact allergies. Therefore, fewer allergies against palladium are diagnosed than those against nickel and cobalt. Nonetheless, Pd2+ exhibited higher frequencies of CD154+ in an in vitro activated marker …

    fu-berlin Repository record for Penetration of harmful substances into the skin: polycyclic aromatic hydrocarbons and metal allergens (opens in a new tab)

Page 1 of 3