Results 1 to 20 of 57 for “"Patient Model"”

  1. Articulated patient model in high-precision radiation therapy

    … radiotherapy, changes in the anatomy of the patient over the course of treatment pose a major challenge. An accurate assessment of occurring anatomical variations is the key requirement to enable an adaptation of the treatment plan for ensuring a highly precise treatment. Comparison of …

    heid-diss Repository record for Articulated patient model in high-precision radiation therapy (opens in a new tab)

  2. Applications of a Biomechanical Patient Model for Adaptive Radiation Therapy

    Biomechanical patient modeling incorporates physical knowledge of the human anatomy into the image processing that is required for tracking anatomical deformations during adaptive radiation therapy, especially particle therapy. In contrast to standard image registration, this enforces bio-fidelic …

    heid-diss Repository record for Applications of a Biomechanical Patient Model for Adaptive Radiation Therapy (opens in a new tab)

  3. Validating a computational model of patient illness: the Simcare Patient Model.

    The SimCare Patient Model is a computational model of individuals with type 2 diabetes. The model represents a patient as a sequence of health states that respond to treatments over varying intervals of time. It was originally constructed as a “clinical” model of an “individual patient” with type 2 …

    umn Repository record for Validating a computational model of patient illness: the Simcare Patient Model. (opens in a new tab)

  4. Risk amid Protection and Motivation: A Communicative Cardiovascular Physician-Patient Model of Message Preparation-Perception (CPMP)2

    … is essential in the field of health to ensure patients understand the information being presented to them by medical professionals and appreciate the level of risk involved in treatments. Cardiovascular disease, being the leading cause of death worldwide, is relevant to consider when examining …

    ottawa-retro Repository record for Risk amid Protection and Motivation: A Communicative Cardiovascular Physician-Patient Model of Message Preparation-Perception (CPMP)2 (opens in a new tab)

  5. Finite Element Modeling of the Mitral Valve and Mitral Valve Repair

    … studying the mitral valve ex vivo, incorporating patient data and the effects of different repair techniques on the valve prior to surgery. In this study, a method was developed for reconstructing the mitral valve from patient-specific data. Three-dimensional transthoracic and transesophageal …

    ottawa-retro Repository record for Finite Element Modeling of the Mitral Valve and Mitral Valve Repair (opens in a new tab)

  6. VIRTUAL FLUOROSCOPY SYSTEM FOR ARTHROSCOPIC SURGICAL TRAINING

    … surgeons prior to performing such procedures on patients.</p> <p>In this thesis I explored a novel idea for creating a training system for arthroscopic surgery. Previously obtained CT images of a patient model and the surgical tools are manipulated to create a library of fluoroscopy images. The …

    mcmaster Repository record for VIRTUAL FLUOROSCOPY SYSTEM FOR ARTHROSCOPIC SURGICAL TRAINING (opens in a new tab)

  7. Design of control systems for regulation of mean arterial blood pressure of hypertension patients

    … postoperative hypertension is common in cardiac patients and untreated hypertension patients may result in complications. This thesis mainly presents a fuzzy logic multiple-model adaptive control system for postoperative blood pressure management. Multiple-model adaptive control (MMAC) algorithm …

    nanyang Repository record for Design of control systems for regulation of mean arterial blood pressure of hypertension patients (opens in a new tab)

  8. Protein-bound uremic toxin kinetics modeling for a new dialysis device

    … device, we build a fixed-bed adsorbent column model to simulate this process. Also, we build a compatible hemodialysis model with Python language. This hemodialysis model consists of a three-compartment patient model, a dialyzer model and toxin removal unit models where the PBUTs adsorption …

    washington Repository record for Protein-bound uremic toxin kinetics modeling for a new dialysis device (opens in a new tab)

  9. Medical Device Interoperability With Provable Safety Properties

    … devices have the potential to radically improve patient safety and the effectiveness of medical treatment. Medical device interoperability requires devices to have an open, standards-based interface that allows communication with any other device that implements the same interface. This will …

    penn Repository record for Medical Device Interoperability With Provable Safety Properties (opens in a new tab)

  10. Behandlingsplanering för mikrovågshypertermi i huvud och halsregionen: En undersökning av patientmodellering och frekvensoptimering

    … hyperthermia treatment requires careful and patient-specific treatment planning. The project aimed to evaluate the feasibility of creating a usable patient model from CT and MRI data and to investigate how the choice of frequency affects the heating efficiency in microwave hyperthermia in the …

    chalmers Repository record for Behandlingsplanering för mikrovågshypertermi i huvud och halsregionen: En undersökning av patientmodellering och frekvensoptimering (opens in a new tab)

  11. Design of computerized drug delivery control systems

    A fuzzy controller-based multiple-model adaptive control system (FCMMAC) for drug delivery control system was presented in this report. We developed a multiple-model adaptive control (MMAC) algorithm to identify the patient model, because the transfer function parameters were different for each …

    nanyang Repository record for Design of computerized drug delivery control systems (opens in a new tab)

  12. Assessing the passive fit of milled titanium substructure produced from different digitalimpression techniques.

    … techniques, and the abutment replica of the patient model.Materials and Methods: Four implant Simulated Patient Model was duplicated from a demonstration resin model. The implant impression of the edentulous arch was obtained using 6 techniques: Conventional splinted Open-Custom tray …

    ohiolink Repository record for Assessing the passive fit of milled titanium substructure produced from different digitalimpression techniques. (opens in a new tab)

  13. Pilot Case Studies to Assess the Effectiveness of the DTI Marketing Consultancy Initiative

    … intent of the client company, and the style model the consultant employed. The findings suggest that in the case studies, the most effective intervention occurred when the strategic intent was of the Analyser and the consultants style was of the Enlightened Doctor/Patient model. Finally, …

    aston Repository record for Pilot Case Studies to Assess the Effectiveness of the DTI Marketing Consultancy Initiative (opens in a new tab)

  14. A Biomechanical Simulation Framework for Upper Limb Rehabilitation Assistance Using Cable Driven Parallel Robots

    … robotic systems that adapt assistance to each patient’s residual motor capacity. Cable Driven Parallel Robots (CDPRs) are promising candidates, yet most studies rely on simplified patient representations that limit simulation realism. This thesis presents an inte grated Assist as Needed (AAN) …

    uniandes Repository record for A Biomechanical Simulation Framework for Upper Limb Rehabilitation Assistance Using Cable Driven Parallel Robots (opens in a new tab)

  15. Fully-Integrated Control: Noise Filtering, Parameter Estimation, Disturbance Determination and Predictive Control of Biological Nonlinear Processes

    … malfunction. With the growing number of diabetic patients worldwide, along with the hassle of the treatment, it becomes imperative to find ways to accurately control diabetes with very little user interaction. This work presents development of the required methods for a fully itegrated control …

    south-carolina Repository record for Fully-Integrated Control: Noise Filtering, Parameter Estimation, Disturbance Determination and Predictive Control of Biological Nonlinear Processes (opens in a new tab)

  16. Cardiovascular system modeling and simulation

    This report deals with modeling and computer simulation of the cardiovascular system. The modeling focuses on the left heart and the complete cardiovascular system modeled close to the actual heart. Specific attention is given to the modeling of blood flow in the cardiovascular system. The …

    nanyang Repository record for Cardiovascular system modeling and simulation (opens in a new tab)

  17. Unterstützung der Entscheidungsfindung bezüglich der Therapie mit Immuncheckpointinhibitoren bei rekurrenten/metastasierten(R/M) Kopf-Hals-Karzinomen durch Bayes’sche Netze

    … tumor boards (MDTBs). By considering the patient’s tumor properties, molecular pathological test re-sults, and comorbidities, the MDTB has to consent an evidence-based treatment decision. Im-munotherapies are increasingly important in today’s cancer treatment, resulting in detailed …

    qucosa-diss Repository record for Unterstützung der Entscheidungsfindung bezüglich der Therapie mit Immuncheckpointinhibitoren bei rekurrenten/metastasierten(R/M) Kopf-Hals-Karzinomen durch Bayes’sche Netze (opens in a new tab)

  18. Investigation of Glutathione S-Transferase (GST) expression and activity in mouse with Multiple Sclerosis (MS)

    … C57BL/6 mouse autoimmune encephalomyelitis (EAE) model. There was no statistically significant difference (p ≤ 0.05) in mouse liver GST protein expression between the two groups of animals, the MS patient model and the control group. However, higher GST enzyme activity was detected in the MS group …

    metu Repository record for Investigation of Glutathione S-Transferase (GST) expression and activity in mouse with Multiple Sclerosis (MS) (opens in a new tab)

  19. Experimental validation of a collision avoidance software in radiation therapy

    … enhances the possibility of couch-gantry or patient-gantry collision, a safety concern. To prevent collisions from occurring, this work presents a collision avoidance computer program. It simulates a treatment plan using a linac, couch and patient model using a collision detection algorithm. …

    gatech Repository record for Experimental validation of a collision avoidance software in radiation therapy (opens in a new tab)

  20. Advisory system for administration of Phenylephrine following spinal anesthesia for cesarean section

    … blood pressure response. Data was collected from patients undergoing Cesarean Section at the British Columbia Women's Hospital for drug response modeling. Preliminary results indicated that the quality of noninvasive blood pressure measurement by the existing cuff sphygmomanometry was a prominent …

    ubc Repository record for Advisory system for administration of Phenylephrine following spinal anesthesia for cesarean section (opens in a new tab)