An Evaluation of The Consistency of Imrt Patient-Specific Qa Techniques
… through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard among clinical institutions, and many devices and action levels are used. Since the acceptance criteria …
-
An AI-driven, Virtual DVH-Based Patient-Specific QA Framework for Lung SBRT VMAT
… calculation and delivery, necessitating rigorous patient-specific quality assurance (PSQA). Traditional measurement-based PSQA, while standardized and widely adopted according to AAPM Task Group 218 (TG218) guidelines, is limited by its resource-intensive workflow and its reliance on gamma passing …
-
Validation and Implementation of Automated Planning Optimization in Utah Valley Hospital
… Subsequently, a complementary institution-specific SRS model tailored to single-isocenter multitarget workflows was created. Seventy retrospectively selected patients were replanned using RapidPlan-generated objectives under identical beam configurations, prescriptions, and normalization …
-
Creating A Dynamic, Multi-Purpose Correction for Multiple Geometries and Field Sizes to Account for Off-Axis and Asymmetric Backscatter With Varian Portal Dosimetry
… be accurately measured for quality assurance (QA). One of the most efficient ways to perform patient-specific QA when using clinical linear accelerators (linac) is to use an electronic portal imaging device (EPID). Amorphous silicon (aSi) Electronic Portal Imaging Devices (EPIDs) are attached …
-
Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout
… to offer optimal tumour control while preserving patient quality of life by avoiding damage to healthy tissue. This increased complexity requires more thorough quality assurance (QA). External beam radiation therapy has seen an increase of QA of individual patients’ treatments for complex …
-
Comprehensive Calculation-Based Imrt Qa Using R&V Data, Treatment Records, and A Second Treatment Planning System
Purpose: Traditional patient-specific IMRT QA measurements are labor intensive and consume machine time. Calculation-based IMRT QA methods typically are not comprehensive. We have developed a comprehensive calculation-based IMRT QA method to detect uncertainties introduced by the initial dose …
-
Σχεδιασμός ογκομετρικά διαμορφούμενης τοξοειδούς ακτινοθεραπείας (VMAT) κεφαλής-τραχήλου: σύγκριση βελτιστοποίησης μέσω βιολογικών και φυσικών παραμέτρων για τους σιελογόνους αδένες
… Εξατομικευμένη Επιβεβαίωση Πλάνου Θεραπείας (patient specific QA) για την εξακρίβωση της παράδοσης των πλάνων θεραπείας, που σχεδιάστηκαν στο Monaco, εξετάζοντας ως κριτήριο αποδοχής το 3%/2mm, η οποία έδειξε πως όλα τα πλάνα ικανοποιούν το κριτήριο αποδοχής 95% (γ-index). Έπειτα με τη βοήθεια …
-
Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method
In vivo dosimetry is widely used for patient specific dose evaluation and treatment verification in external beam radiation therapy (EBRT). There is a growing interest in using an electronic portal imaging device (EPID) for in vivo dosimetry, by correlating pixel values of measured EPID images to …