Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 91 for “"Patient motion"”

  1. Data-Driven Patient Motion Compensation in Cardiac Positron Emission Tomography

    … disease can be marred in cases where patient motion is severe. Clinical use of motion tracking/compensation tools, however, is relatively uncommon partly due to the increases in complexity and time of patient setup prior to imaging. The purpose of the work described here was to develop …

    carleton Repository record for Data-Driven Patient Motion Compensation in Cardiac Positron Emission Tomography (opens in a new tab)

  2. 3D patient motion estimation and correction for dynamic reconstruction in medical tomosynthesis

    … 2D classiques tout en limitant l'irradiation des patientes. Néanmoins, lorsque les conditions d'acquisition optimale, comme l'absence de mouvement, ne sont pas respectées, des artéfacts compromettent la visibilité des signes cliniques et réduisent l'efficacité du dépistage et diagnostique. Ce …

    star-france Repository record for 3D patient motion estimation and correction for dynamic reconstruction in medical tomosynthesis (opens in a new tab)

  3. Detection and correction of rigid patient motion in SPECT with exponential data consistency conditions

    … (jusqu'à 40 minutes), des mouvements rigides du patient sont susceptibles de se produire pendant la TEMP. Ces mouvements peuvent dégrader la qualité de l'image reconstruite, compromettant ainsi la précision et la fiabilité du diagnostic et du traitement. Les conditions de conditions de cohérence …

    star-france Repository record for Detection and correction of rigid patient motion in SPECT with exponential data consistency conditions (opens in a new tab)

  4. Large-scale Modelling of Patient Motion for Head Coils at 7T Using Magnetic Resonance Integral Equations

    … rate (SAR) at ultra-high field (UHF) MRI for patient safety, are too computationally expensive and may prevent taking advantage of full capabilities of superior image resolution at higher fields due to conservative safety margins. A new approach using magnetic resonance Green’s functions …

    kings Repository record for Large-scale Modelling of Patient Motion for Head Coils at 7T Using Magnetic Resonance Integral Equations (opens in a new tab)

  5. CAMIRA: Correction Advances for Myocardial Imaging using Registration Algorithms

    … Aim: To determine the extent and frequency of patient and respiratory motion artefacts on myocardial perfusion images acquired on the DNM 530c and develop data driven motion estimation and correction techniques that utilise the three-dimensional nature of the system. Method: The effect of …

    whiterose Repository record for CAMIRA: Correction Advances for Myocardial Imaging using Registration Algorithms (opens in a new tab)

  6. Image-Guided Interventions Using Cone-Beam CT: Improving Image Quality with Motion Compensation and Task-Based Modeling

    … image quality — notably, the major challenges of patient motion and detectability of low-contrast structures — which motivate the work undertaken in this thesis. A 3D–2D registration method is presented to compensate for rigid patient motion. The method is fiducial-free, works naturally within …

    jhu Repository record for Image-Guided Interventions Using Cone-Beam CT: Improving Image Quality with Motion Compensation and Task-Based Modeling (opens in a new tab)

  7. A Study of the Prevalence of Patient Body Motion and Its Subsequent Correction by Projection Consistency Conditions

    Patient motion is a common problem during dynamic PET scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting, and evaluate with realistic phantoms the effects of motion on blood flow quantification, …

    carleton Repository record for A Study of the Prevalence of Patient Body Motion and Its Subsequent Correction by Projection Consistency Conditions (opens in a new tab)

  8. Event-Driven Motion Compensation in Positron Emission Tomography: Development of a Clinically Applicable Method

    … due to the monitoring of the metabolism of the patient over a certain time. Therefore, patient motion increasingly limits the possible spatial resolution of PET. In addition, patient immobilisations are only of limited benefit in this context. Thus, patient motion leads to a relevant resolution …

    qucosa-diss Repository record for Event-Driven Motion Compensation in Positron Emission Tomography: Development of a Clinically Applicable Method (opens in a new tab)

  9. New Methods for Motion Management During Radiation Therapy

    … techniques for the management of intrafractional motion during radiation therapy are presented. Intra-fractional motion describes all kinds of anatomy changes - most prominently respiration - that occur during a single treatment session. Spatially confining the radiation dose to the tumour tissue …

    heid-diss Repository record for New Methods for Motion Management During Radiation Therapy (opens in a new tab)

  10. The development and evaluation of head probes for optical imaging of the infant head

    … sensitive to external sources of light and patient motion. A series of prototype adaptable helmets were developed for optical tomography of the premature infant brain using the UCL 32-channel time-resolved system. They were required to attach 32 optical fibre bundles over the infant scalp, …

    ucl Repository record for The development and evaluation of head probes for optical imaging of the infant head (opens in a new tab)

  11. Analysis of dynamic contrast enhanced MRI datasets

    … which a contrast agent pre-injected into a patient enhances disease affected tissues. Measurement of this enhancement, which is specific to voxels representing particular tissue types, allows assessment of the patient's condition. Currently, analysis of DCE-MRI data is performed using …

    whiterose Repository record for Analysis of dynamic contrast enhanced MRI datasets (opens in a new tab)

  12. Deep Autofocus for Motion Compensation in Cone-Beam Computed Tomography

    … makes images susceptible to artifacts caused by patient motion, degrading image quality despite common motion control protocols such as patient immobilization and breath-holding. Autofocus algorithms for motion compensation in CBCT can mitigate motion artifacts in existing data by incorporating …

    jhu Repository record for Deep Autofocus for Motion Compensation in Cone-Beam Computed Tomography (opens in a new tab)

  13. Towards Fast, Accurate, and Robust Magnetic Resonance Fingerprinting

    … scan acceleration, system imperfections, and patient motion. The objective of this work is to improve the scan efficiency, robustness, and measurement accuracy of MRF scans against errors arising from these confounding factors. The following projects all contribute to this goal by optimizing …

    ohiolink Repository record for Towards Fast, Accurate, and Robust Magnetic Resonance Fingerprinting (opens in a new tab)

  14. Motion-corrected treadmill nuclear angiography

    … exercise and the use of this technique in patients with coronary artery disease (CAD) is significant compared with other methods such as echocardiography. However, patient motion and resulting image blurring during treadmill exercise can significantly degrade resolution and introduce …

    rice Repository record for Motion-corrected treadmill nuclear angiography (opens in a new tab)

  15. Motion Detection in Dynamic Cardiac Positron Emission Tomography Images

    … This assumption is violated in the presence of patient motion and heart motion. This thesis discusses methods for motion detection in dynamic cardiac 82Rb PET images.First, we determined if positron-emitting fiducial markers can be used as surrogate markers for heart motion in dynamic PET …

    carleton Repository record for Motion Detection in Dynamic Cardiac Positron Emission Tomography Images (opens in a new tab)

  16. A Dosimetric Study of a VMAT Head and Neck Treatment Plan Using TLDs and Gafchromic Films

    … as one of the new techniques for treating cancer patients. This smart arc therapy decreases the treatment time, which decreases the patient motion and the internal motion of the tumor. This thesis came to study the accuracy of this kind of treatment in heterogenetic region like the head and neck …

    south-carolina Repository record for A Dosimetric Study of a VMAT Head and Neck Treatment Plan Using TLDs and Gafchromic Films (opens in a new tab)

  17. Automatic registration and segmentation of abdominal images and detection of pancreatic cancer

    … and sometimes unfeasible due to the effects of patient motion and breathing. This is particularly evident during analysis of the pancreas for cancer, due to its proximity to other intra-abdominal organs. Within subject registration thus becomes imperative for pathological analysis of pancreatic …

    njit Repository record for Automatic registration and segmentation of abdominal images and detection of pancreatic cancer (opens in a new tab)

  18. Artifact reduction in functional magnetic resonance imaging

    … blood flow, variations in NMR signal phase, and patient motion. A new method of MR imaging called partial presaturation (PSAT) was developed that allows fMRI studies to be performed with reduced sensitivity to blood flow. The method is more effective than previous techniques for eliminating blood …

    manitoba Repository record for Artifact reduction in functional magnetic resonance imaging (opens in a new tab)

Page 1 of 5