Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 31 for “"Pcasl"”
-
The role of cerebral blood flow in Gulf War Illness using PCASL
… called pseudo-continuous arterial spin labeling (PCASL) has become a favorable technique in ASL research because it combines the advantages of continuous arterial spin labeling (CASL) and pulsed arterial spin labeling (PASL). PCASL can quantify the absolute cerebral blood flow without the …
-
Assessment of Pseudo-Continuous Arterial Spin Labeling (pCASL) Inter-Session Reliability in the Quantification of Cerebral Perfusion
… ASL technique known as pseudo-continuous ASL (pCASL). This form of ASL is the clinical standard (Alsop et al., 2015). However, it is not well documented the that pCASL is reliable between sessions spanning days to weeks. In this study, we assessed the inter-session reliability of CBF through …
-
Optimierung der Labeling-Effizienz von pseudo-kontinuierlichem Arteriellem Spin-Labeling (pCASL) für die Messung der zerebralen Perfusion
… Arterielles Spin-Labeling (pCASL) als nichtinvasive Methode in der Magnetresonanzbildgebung etabliert. Das Anliegen der vorliegenden Arbeit ist es, pCASL zu charakterisieren und die Ursache für dessen Empfindlichkeit gegenüber intrinsischen Magnetfeldgradienten zu …
-
Vascular imaging in brain metastasis
… pseudo-continuous labelling approach (MP-pCASL MRI). This sequence and its output cerebral blood flow (CBF) measurements were validated with gold-standard autoradiography and, subsequently, applied to a rat breast cancer brain metastasis model. CBF was monitored during tumour progression …
-
Developments in preclinical arterial spin labeling
… ASL continues et pseudo-continues (CASL, pCASL) ainsi qu'à améliorer leur performance en pré-clinique. En effet, la mesure quantitative de CBF par ASL est un protocole complexe qui nécessite plusieurs étapes d'ajustements, d'acquisitions et de traitement de données. Dans le but d'alléger …
-
Optimisation of Arterial Spin Labelling MRI for the assessment of perinatal brain injury
… imaging technique called pseudo-continuous ASL (pCASL). However, the use of pCASL for neonatal CBF assessment in research or clinical practice is still uncommon due to several challenges specific to this patient group. This thesis addressed some of the acquisition and quantification challenges …
-
Functional Evaluation of the Peripheral Vasculature Using Magnetic Resonance Imaging
… method for the brain, pseudo-continuous ASL (pCASL). Assessment of the impact of blood flow variability throughout the ischemia-reperfusion paradigm on pCASL perfusion quantification is investigated. Then, both PASL and pCASL sequences are used to measure reactive hyperemia perfusion in …
-
Time-efficient methods for non-invasive brain blood flow imaging using arterial spin labelling MRI
… a range of existing pseudo-continuous ASL (PCASL) perfusion protocol designs, including time- encoded preparations, from the literature and to explore novel protocol designs. These comparisons allowed the advantages and disadvantages of each approach to be explored, and recommendations about …
-
Développement de l'imagerie de perfusion cérébrale par marquage des spins artériels
… la séquence ASL de marquage pseudo-continu (pCASL) et évalué sa réponse à un stimulus hypercapnique. Nous avons évalué différentes stratégies pour optimiser l'efficacité d'inversion. Pour cela, nous avons également mis en place des outils de simulations numériques des approches ASL. Nos …
-
Quantification of cerebral vascular hemodynamics using MRI
… the standard implementation of ASL (single-PLD PCASL) and a novel ASL technique (Turbo QUASAR ASL). CVR, ATT, and blood flow velocity were estimated before and after acetazolamide administration in healthy volunteers. Regional differences of CVR were found between the two ASL methods. Both PCASL …
-
Applications pré-cliniques de l'IRM de perfusion
… l'utilisation d'un marquage de type unbalanced-pCASL (pseudo-Continuous ASL). Ces travaux de thèse ont pour objectif la mise en place, le test et la validation de la séquence pCASL sur un IRM préclinique 7T et l'utilisation de cette méthode pour l'étude des changements de perfusion cérébrale en …
-
Improving the quantification of cerebral haemodynamics using optimally sampled arterial spin labelling MRI
… delay (PLD) pseudo-continuous ASL (pCASL) method to robustly quantify CBF, there has been a growing body of research on multi-delay ASL which provides the ability to estimate for parameters other than CBF.</p> <p>A framework applying optimal sampling strategy (OSS) to multi-PLD pCASL …
-
MAGNETIC RESONANCE IMAGING OF CEREBRAL PERFUSION
… we developed a modified pseudo-continuous ASL (pCASL) technique, large-vessel-suppression pCASL (LVS-pCASL) for neonatal perfusion imaging, addressing challenges of vascular artifacts and low SNR. This approach enabled reliable estimation of CBF within clinically feasible scan time. Third, we …
-
Application of Arterial Spin Labelling as perfusion imaging in acute and chronic ischaemic stroke patients
… 3, two commonly used ASL sequences which were PCASL with multi-post labelling delays (multi-PLDs) and PASL (single-PLD), were compared to investigate their agreement. 35 subjects from WHISPER study underwent ASL scanning for both sequences. Grey matter and white matter CBF for these subjects …
-
Optimisation des techniques non invasives d'IRM de perfusion cérébrale et d'imagerie spectroscopique par résonance magnétique pour l'exploration des pathologies cérébrales
… type marquage de spins,PASL PICORE, PASL FAIR et pCASL, ont été comparées en termes de sensibilité et de reproductibilité. pCASL a ensuite été intégrée dans un protocole de recherche sur des patients atteints de sclérose en plaques ou SEP. Quant au métabolisme cérébral, un protocole a été mis en …
-
Imaging angiogenesis in brain metastasis
… validated multiphase pseudo-continuous ASL (MP pCASL) for use in mice. This sequence was then used to measure and identify areas of reduced CBF in mouse models of brain metastasis and glioma. </p> <p>Integrin αvβ3 is a marker of angiogenesis expressed on tumour blood vessels, including in brain …
-
Investigation of the neural correlates of ongoing pain states using quantitative perfusion arterial spin labelling
… with the newly acquired pseudo-continuous ASL (pCASL); a novel ASL technique that benefits from maximal signal-to-noise (SNR) across a whole-brain volume. In Chapter 4 we implement the pCASL FMRI approach to image the neural correlates of ongoing experimental pain. Results from the investigation …
-
Measurement of Cerebral Blood Flow Using Arterial Spin Labeling Magnetic Resonance Imaging
… Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI is a new MRI technique that is able to detect blood flow changes, non-invasively. The blood flow change detected by pCASL MRI is relative and it is expressed in terms of arbitrary MRI units which does not have any physiological meaning. …
-
Investigating markers of Alzheimer’s disease in posttraumatic stress disorder using machine learning and magnetic resonance imaging
… (pseudo-continuous arterial spin labelling [pCASL] and structural magnetic resonance imaging [MRI]) and behavioral data for the current study (n = 67) were taken from our non-randomized, open label clinical trial (ClinicalTrials.gov Identifier: NCT03229915) for treatment-seeking individuals …
-
Modulating functional brain connectivity using high-definition transcranial direct current stimulation (HD-tDCS)
… and pseudo-continuous arterial spin labeling (pCASL). HD-tDCS (2 mA, 20 min) was administered using 9 electrodes positioned to optimize inward current to each target. Rs-fMRI and pCASL were repeated. ANAM was repeated after the scanning session. Functional connectivity and cerebral blood flow …
Page 1 of 2