Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 11 of 11 for “"Pd-103"”.
-
Radiobiological modeling of Pd-103 permanent breast seed implant brachytherapy using Monte Carlo dose calculations
… sensitivity as well as the effectiveness of Pd-103 permanent breast seed implant brachytherapy (PBSI) treatments. Dose distributions are obtained following both the standard TG43 protocol and using realistic tissue models as recommended by TG186. Discrepancies in dose are investigated and …
-
RADIONUCLIDES FOR MEDICINE - EXCITATION FUNCTIONS FOR THE PRODUCTION OF TC-99M, ZR-89 AND PD-103
… of three main radionuclides Tc-99m, Zr-89 and Pd-103 irradiating, correspondingly, targets of enriched molybdenum-100, natural yttrium-89 and natural rhodium-103 with proton or deuteron beams accelerated by cyclotrons. Formation of several by-products synthesized in the same targets is also …
-
Investigation of a Monte Carlo model based dose calculation for Pd-103 low dose rate breast brachytherapy and I-125 low dose rate prostate brachytherapy
… of 80 breast brachytherapy cases treated with Pd-103 seeds (TheraSeed200, 2.3-2.8 U, 90 Gy prescription dose) and 76 prostate cases treated with I-125 seeds (AgX100, 0.354-0.493 U, 144 or 110 Gy prescription doses) were simulated using the MC program and doses were calculated using two methods: …
-
Optically Stimulated Luminescence Dosimetry in Permanent Breast Seed Implant Brachytherapy: a Monte Carlo Approach
… typically performed with low energy radioactive Pd-103 x-ray sources, is a convenient treatment option for many low risk breast cancer patients. Skin is a primary organ at risk (OAR) in PBSI and is susceptible to painful toxicities when exposed to large doses of radiation. The TG-43 formalism …
-
Dosimetric characterization of elongated brachytherapy sources using Monte Carlo methods
… Low- and high-energy photon-emitting sources of Pd-103 and Ir-192, respectively, were examined.
-
An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant
… planning strategies incorporating various Pd-103 seed activities, needle and seed spacings, and implants in which seed positions are either restricted to or permitted outside of spherical target volumes. To address more realistic geometries, model parameters were used to re-plan a 5-patient …
-
Monte Carlo Dose Calculations for Permanent Breast Seed Implant Brachytherapy
… patient models are created and overlaid with Pd-103 seed geometries, allowing for simulations with egs_brachy, a new Monte Carlo code.Considerable discrepancies in dose distributions are demonstrated. Target dose metrics are 4-26\% higher using TG43 assumptions, skin metrics are underestimated …
-
Model-based dose calculations for eye plaque brachytherapy
… for three photon-emitting radionuclides, I-125, Pd-103 and Cs-131. Doses to ocular structures for the full eye model are compared to those for a homogeneous water phantom, both including and excluding (TG-43) inter-seed and eye plaque effects. Doses for the full eye model simulations are shown to …
-
MCNP modeling of prostate brachytherapy and organ dosimetry
… to the organs of interest delivered by 125I and 103Pd. As expected, the organs nearest to the prostate received the highest energy depositions and the organs farthest from the prostate received the lowest energy depositions. Once the energy depositions were calculated, the doses to the organs …
-
Theoretical orientation, experience, and the observation of patient behavior in a supervisory setting
… Orientation catagories were: Psychodynamic (PD), Behavioral/ Cognitive (BC), and Systems/Communication (SC).</p> <p>Results indicated orientations and overall experience levels were similar with regard to homogeneity of selections. Within orientation experience homogeneity differed for BC but …
-
Combining Monte Carlo simulations and detector measurements for a novel quality assurance system of assembled brachytherapy eye plaques.
… quality assurance system for assembled I-125 and Pd-103 brachytherapy eye plaques. The detector is used in conjunction with an acrylic plaque holder to record the 2D dose distribution of the plaque perpendicular to the plaque central axis. The system is simulated in Monte Carlo to generate a 3D …