Showing 1 to 20 of 87 for “"Peak Capacity"”.
-
Advances in Instrumentation and Data Analysis Techniques for Increasing Peak Capacity and Peak Capacity Production in One and Two-Dimensional Gas Chromatography
Techniques to substantially increase peak capacity (number of peaks per separation window) and peak capacity production (number of peaks produced per unit time) for one and two-dimensional gas chromatography are demonstrated. First, instrumental advances related to sample introduction and column …
-
Novel Injection Techniques to Enable Fast, High Peak Capacity Gas Chromatography Separations
… increasingly complex samples requires improved peak capacity production (peak capacity per separation run time) from the separation. The increased peak capacity production was achieved by selecting appropriate experimental conditions based on theoretical modeling of on-column band broadening , …
-
Evaluating the effective peak capacity of a saw-tooth gradient for reverse-phase high performance liquid chromatography separation of proteins and peptides
… high performance liquid chromatography. The peak splitting and number of peptides detected is used to characterize the effective peak capacity of the saw-tooth gradient as a function of solvent strength change (Delta&phis;). Peak splitting demonstrated in experimental result as one single …
-
Development of Ultra-Fast Modulation for Application in Multi-Dimensional Gas Chromatography
… improves the efficiency, resolving power (i.e. peak capacity/ peak capacity production), and lessens the typical time of multi-dimensional gas chromatography (MDGC) separation in a straightforward, easily interpretable manner. Application of partial modulation via a commercially available high …
-
High Speed Separations of Complex Mixtures using nano-Liquid Chromatography Coupled with micro Free Flow Electrophoresis
… and fabricated for coupling with nLC. High peak capacity separations of tryptic peptides of BSA demonstrated the power of the technique. Broadening in temporal and spatial dimensions were investigated since peak capacity is calculated using analyte peak width. The observation that the …
-
Advances in two-dimensional liquid chromatography
… liquid chromatography (LC×LC) offers increased peak capacity, resolution and selectivity compared to one-dimensional liquid chromatography. It is commonly accepted that the technique produces the best results when the separation mechanisms in the two dimensions are completely orthogonal, which …
-
Development of New Modulation Methods Using the Pulse Valve Modulator for Multidimensional Gas Chromatography
… mode (PPM). The NPM produces comparable analyte peak widths-at-base (wb) as the PPM but does so with greater S/N and with less data processing required. In the 1D-GC mode, 8 analytes are baseline resolved (Rs ≥ 1.5) in a 200 ms window, providing a peak capacity, nc, of 14 at unit resolution (Rs = …
-
Polymeric Monolithic Stationary Phases for Capillary Hydrophobic Interaction Chromatography
… using a 20 min elution gradient, resulting in a peak capacity of 54. The performance of this monolithic column for HIC was comparable or superior to the performance of columns packed with small particles. Monoliths synthesized solely from PEGDA were also found to show excellent performance in HIC …
-
Development of Instrumental and Chemometric Techniques for the Analysis of Complex Samples via Multi-Dimensional Gas Chromatography
… improve the efficiency and resolving power (i.e. peak capacity/ peak capacity production) of multi-dimensional gas chromatography (MDGC) as well as provide straightforward, easily interpretable chemical information. Implementation of a high speed pulse flow valve for two-dimensional gas …
-
Comprehensive Multidimensional Separations of Biological Samples using Capillary Electrophoresis coupled with Micro Free Flow Electrophoresis
… directly into the µFFE separation channel. High peak capacity separations of trypsin digested BSA and small molecule bioamines demonstrated the power of CE × µFFE. Since both methods rely on electrophoretic mobility to separate, an investigation on the orthogonality of the two techniques was …
-
Development of a Cost-Effective and Consumable-Free Interface for Comprehensive Two-Dimensional Gas Chromatography (GC×GC)
… conventional gas chromatography (GC) is limited peak capacity, making the analysis of complex mixtures a difficult or even impossible task. Comprehensive two-dimensional gas chromatography (GC×GC) significantly increases peak capacity and resolution, improves sensitivity and generates structured …
-
Development of Microfluidic Chips for High Performance Electrophoresis Separations in Biochemical Applications
… The research also focuses on improving the peak capacity and separation resolution of two counter-flow gradient electrofocusing methods: Temperature Gradient Focusing (TGF) and Micellar Affinity Gradient Focusing (MAGF). In these techniques, a temperature gradient across a microchannel or …
-
Complex Mixture Analysis Using Ion Mobility Spectrometry-Mass Spectrometry (IMS-MS) and Computational Techniques
… include the overwhelming of the analytical peak capacity, the wide concentration range of the different analytes, and the inter-sample concentration variability of given molecular species. Therefore advances in the rapid identification of compounds such as improvements in peak capacity and …
-
Determining The Capacity Requirements Of Coal Mine Gathering Belts.
… loads from two or more sources. Therefore the capacity requirements for these belts are dependent upon the individual source loads that will superimpose on them. Since belt loading is intermittent and often of short and varying duration, it is difficult to determine the extent of this …
-
Fundamental Considerations in One and Two-Dimensional Chromatography for Improved Chemometric Analysis
… based on sample complexity, separation peak capacity, nc, and the algorithm specific limit of chemometric resolution using a simulation based study of multivariate curve resolution alternating least squares for demonstration. For comprehensive two dimensional gas chromatography the …
-
Development of theory, instrumentation, and chemometric data analysis tools for comprehensive two- and three-dimensional gas chromatography
… cost-prohibitive and is not op timized for high peak capacity. Second, the technique generates large and complex data, requiring many man-hours of analysis by an expert user(s) to generate chemically meaningful information. This dissertation presents several developments in instrumentation, data …
-
Investigation of the Fundamentals of Electrospray Ionization and the Separation of Small Molecules using Ion Mobility Mass Spectrometry
… Drift gas selectivity was quantified using peak capacity and peak-to-peak resolution. Those results show that the identities of the pairs of amino acids separated depends on the drift gas and the number of pairs separated depends on peak capacity. The collision cross sections of ten …
-
Development of matrix assisted laser desorption ionization-ion mobility-orthogonal time-of-flight mass spectrometry as a tool for proteomics
… large peptide datasets in order to determine the peak capacity of the method for bottom-up experiments in proteomics, and it is found that IM separation increases the peak capacity of an MS-only experiment by a factor of 5-10. The population density of the appearance area for peptides is further …
-
Characterization of Novel Materials as Platforms for Performing Microfluidic Gas Chromatography
… and 8.29 respectively for LTCC and titanium. Peak capacity was also probed using temperature programming with a simple nC8 – nC20 alkane mixture. A cumulative peak capacity of about 53 was obtained for the LTCC tile while the titanium tile gave a value of 48. Polar analyte separations on both …
Page 1 of 5