Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 127 for “"Peak Detection"”.
-
Coherent peak detection algorithms for utra first stage code acquisition
… time. In this thesis, we have devised four new peak detection algorithms for first stage code acquisition. We utilize the available base stations with few multipath signals along with the standard oversampling and pipelining utilization. We compare different coherent and non-coherent combining …
-
Peak detection and statistical analysis of karyotypic variation from flow cytometry data
… an open-source Bioconductor package, ploidyPeaks. The existing flowCore Bioconductor package was used to load flow cytometry data from reference cell populations with known and variable karyotypes into the R programming language. We used reference populations with known ploidy to determine a …
-
Parametric Tracking of the Electroencephalogram in Coma Using a Computerized Peak Detection Method
… analysed off-line on a LINC-8 computer using a peak-detection technique. The algorithm employs a sliding window concept to detect absolute maxima (peaks) and absolute minima (troughs) in the signal. As each peak-trough combination (count) is registered, the amplitude and time-interval are …
-
Analysis of grey level weighted Hough transforms
… space quantizing errors, and Hough space peak detection strategy. One way to improve the accuracy of the transform is to weight each pixel’s Hough space sinusoid by an amount which reflects the pixel’s grey level contribution to an image space feature. This paper examines the behavior of …
-
Data mining in computational proteomics and genomics
… by investigating two important problems, namely peak detection and structure matching. Peak detection is useful for biological pattern discovery while structure matching finds many applications in clustering and classification. The first part of this dissertation focuses on elastic peak detection …
-
P300, Steady State Visual Evoked Potentials, And Hybrid Paradigms For A Brain Computer Interface Speller
… of the SSVEP spelling paradigm including peak detection for different range of frequencies, placement of LEDs, design of the SSVEP stimulus board, and window time for the SSVEP peak detection processing. The next experiment was to evaluate the SSVEP spelling paradigm. Six subjects …
-
Energy Harvesting from Hydraulic and Vibration Sources
… point of displacement. Therefore, an accurate peak detection sensor is required. A new piezoelectric energy harvester integrating a small piezoelectric area for peak detection with a larger piezoelectric area for energy harvesting was designed and fabricated. The difference in capacitance …
-
Post-Processing Method for Determining Peaks in Noisy Strain Gauge Data with a Low Sampling Frequency
… interference. This thesis proposes a peak detection algorithm, written in MATLAB, that can parallel process the 40,000 trips recorded in this naturalistic driving study. This algorithm uses an iterative LOWESS regression to eliminate the offset from zero when the strain gauge is not …
-
Non-linear dynamical analysis of biosignals
… to determine the efficiency of the algorithms. A peak detection algorithm was written to detect the QRS complex. This complex is the most prominent waveform within an ECG signal and its shape, duration and time of occurrence provides valuable information about the current state of the heart. The …
-
Streak Detection in Mottled and Noisy Images
… to pinpoint streak locations and widths using a peak detection algorithm. Finally, for a given peak, the window size is changed adaptively to identify and locate the intensity and length of the corresponding streak while maximizing signal to noise ratio. Results on synthetic and real-life images …
-
Minimizing Uncertainty in the Peak and Zero Crossing Detection of Finite Length Signals
… systems for the problem of finite signal length peak detection in the presence of noise are developed. Where the input signal resembles a parabola, the filter coefficients of the optimum system can be obtained in a straightforward manner for any order system. Where the signal is not well …
-
Acoustic diagnosis of aortic stenosis
A multi-peak detection algorithm is developed to process the phonocardiogram (PCG) signals with the time-frequency methods. Based on the PCG signal, four indicators are produced to predict the severity of the Aortic Stenosis (AS). 64 subjects are classified into three groups of different severities …
-
MALDI-TOF MS Data Processing Using Wavelets, Splines and Clustering Techniques.
… baseline correction, normalization, and peak detection and alignment for biomarker discovery.
-
ScanSAR radiometric calibration based on roll angle Estimatiru
… This "hybrid data" is then used in a new (hybrid peak detection) and modified (three beam) algorithm to provide a more accurate and robust roll estimate. Algorithms using this hybrid data are more tolerant to lower mean scene σ°, gain uncertainty, and other variables than algorithms using normal …
-
Genome-Wide Analysis of Histone Modification Enrichments Induced by Marek's Disease Virus in Inbred Chicken Lines
… First, we present WaveSeq, a novel algorithm for detection of significant enrichments in ChIP-Seq data. WaveSeq implements a distribution-free approach by combining the continuous wavelet transform with Monte Carlo sampling techniques for effective peak detection. WaveSeq outperformed existing …
-
Laser-induced fluorescence measurements of dual plumes and comparison of laser-induced fluorescence and conductivity probe measurements
… comparison of the temporal response and the peak detection are presented. In addition, a proof-of-concept of a two-color LIF technique is presented using Rhodamine 6G paired with an Argon-ion laser and simultaneously Oxazine 725 paired with a Krypton-ion laser. Optical filters on two digital …
-
Capacitive Chest Strap for Heart Rate Monitoring
… investigates various factors affecting the detection of capacitive electrocardiogram (cECG) signals. A comprehensive design process of a rigid printed circuit board (PCB) electrode was presented, covering the modelling of key parameters, prototyping, and testing. The impact of using …
-
Stark cell stabilization of a CO(2) laser
… absorption cell. A dithered Stark voltage gave a peak-detection correction signal fed back to a PZT mounted laser resonator mirror to control the cavity optical length. Operation of an integrator incorporated in the feedback loop to improve the system stability has been investigated. A method was …
-
A Self-Contained Roadway Kinetic Energy Harvesting System for Energy Recovery
… for a novel KEH circuit design. A voltage peak detection function and an energy storage unit voltage hysteresis function have been included in the circuit. The circuit has demonstrated a higher energy harvesting efficiency compared to competitors during tests.
Page 1 of 7