Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 300 for “"Peak Intensity"”.

  1. Using Peak Intensity and Fragmentation Patterns in Peptide SeQuence IDentification (SQID) - A Bayesian Learning Algorithm for Tandem Mass Spectra

    … with greater confidence by incorporating peak intensity information and peptide cleavage patterns obtained in gas-phase ion dissociation research. The underlying hypothesis is that these algorithms can benefit from knowledge about molecular level fragmentation behavior of particular amino …

    arizona-thes Repository record for Using Peak Intensity and Fragmentation Patterns in Peptide SeQuence IDentification (SQID) - A Bayesian Learning Algorithm for Tandem Mass Spectra (opens in a new tab)

  2. Low Energy Electronic Raman Scattering in Cuprate High Temperature Superconductors

    The temperature dependence of the 2$\Delta$-peak in overdoped Tl-2201 implies that the superconducting gap opens very rapidly below the critical temperature. The measured peak intensity as a function of temperature, however, shows an anomalous behavior. A magnetic field is observed to affect Raman …

    uiuc Repository record for Low Energy Electronic Raman Scattering in Cuprate High Temperature Superconductors (opens in a new tab)

  3. Relationship Between Ventilation and Oxygen Uptake at 40% And 85% of Peak Oxygen Uptake in 18-35-Year-Old Women Using the Arm Crank Ergometer

    … and oxygen uptake at 40% and 85% of V02 peak intensity in 30 upper body fit and 30 unfit 18- 35-year-old women. The correlations between ventilation and oxygen uptake at 40% of peak intensity for the fit group (r = -.51) and the unfit group (r = -.48) were modestly negative. At 85% …

    unt Repository record for Relationship Between Ventilation and Oxygen Uptake at 40% And 85% of Peak Oxygen Uptake in 18-35-Year-Old Women Using the Arm Crank Ergometer (opens in a new tab)

  4. Economical fabrication methods of three-dimensional ceramic Photonic Band Gap crystals at micron and submicron scales

    … a 4-layer LBL PBG structure has a characteristic peak in reflectance corresponding to the main bandgap at around 5.0microm wavelength with the peak intensity reaching 35%. An 8-layer structure gives 60% peak intensity and a 12-layer structure has 90% peak intensity. The structures also show the …

    iastate Repository record for Economical fabrication methods of three-dimensional ceramic Photonic Band Gap crystals at micron and submicron scales (opens in a new tab)

  5. Titanium Aluminum Nitride Films Deposited by AC Reactive Magnetron Sputtering: Study of Positioning Effect in an Inverted Cylindrical Magentron Sputtering System

    … Spectroscopy analysis of the samples showed the intensity of the TiAlN characteristic peak of the samples to differ from sample to sample. Results from the XRD analysis of this work showed a 157% and 176% increase in peak intensity of the 0¡Æ tilt sample of the Bottom Plate from the 45¡Æ tilt …

    arkansas Repository record for Titanium Aluminum Nitride Films Deposited by AC Reactive Magnetron Sputtering: Study of Positioning Effect in an Inverted Cylindrical Magentron Sputtering System (opens in a new tab)

  6. WAVEFRONT ENGINEERING TO ENHANCE ATOM-LIGHT INTERACTION

    … the knife-edge method. The beam waist radius, peak intensity, and beam cross-sectional area are taken as the figure of merit for an optimization algorithm to improve focusing. An optimization algorithm based on Zernike polynomials that we developed manages to reduce the waist radius. For the …

    nus Repository record for WAVEFRONT ENGINEERING TO ENHANCE ATOM-LIGHT INTERACTION (opens in a new tab) Download file for WAVEFRONT ENGINEERING TO ENHANCE ATOM-LIGHT INTERACTION (opens in a new tab)

  7. Spatial and spectral photoluminescence characterisation of semiconductor wafers

    … From the spectral information such images as the peak intensity, peak wavelength and the full width at half maximum can be obtained. Several examples of peak wavelength and peak intensity maps of epilayer and quantum well structures grown on GaAs wafers recorded at room, liquid nitrogen and liquid …

    dcu Download PDF for Spatial and spectral photoluminescence characterisation of semiconductor wafers (opens in a new tab)

  8. Second and third order minimum time controllers and missile adjoints

    … of harmonic generation experiments at increasing peak intensity and fluence. Second harmonic beam quality has been measured. Using the oscillator alone, with grating selection of the 9.55 micrometer line, the pulse train consisted of a spike containing about 10 pulses followed by a tail containing …

    nps Repository record for Second and third order minimum time controllers and missile adjoints (opens in a new tab)

  9. Use of fluorescence excitation emission matrix spectroscopy for water and wastewater characterization

    … the fluorescence pattern, center position and peak intensities. It was found that the DI water samples showed scattered but weak fluorescence whereas the tap water samples showed a fluorescence center clustered at excitation 220nm and emission 350nm. The sample has very low fluorescence peak …

    missouri Repository record for Use of fluorescence excitation emission matrix spectroscopy for water and wastewater characterization (opens in a new tab)

  10. Ultra-high-quality bulk Germanium-based thin films for Silicon-compatible photonics

    … wet etching reported. The photoluminescence (PL) peak intensity of the Ge sample (TDD = 6000 cm⁻², n-doping = 10¹⁶ cm⁻³) increased 32-fold when reduced from 535 µm to 2 µm, surpassing the PL peak intensity of 0.75 µm thick epi-Ge on Si (n-doping = 10¹⁹ cm⁻³) by 2.5 times. A 405 µm thick zero-TDD …

    ubc Repository record for Ultra-high-quality bulk Germanium-based thin films for Silicon-compatible photonics (opens in a new tab) Download PDF for Ultra-high-quality bulk Germanium-based thin films for Silicon-compatible photonics (opens in a new tab)

  11. Enhancing QED effects by temporal pulse shaping in laser - electron-beam collisions

    … of plasmas created by laser pulses with high-intensity ≥ 10^23 W/cm^2. Experimental evidence of quantum effects has proven challenging to obtain so far and crucially depend on maximising the electron’s Lorentz invariant non-linearity parameter, χ = ERF/Es, the ratio of the laser electric field …

    whiterose Download PDF for Enhancing QED effects by temporal pulse shaping in laser - electron-beam collisions (opens in a new tab)

  12. AN ANALYSIS OF LOBLOLLY PINE AND SHORTLEAF PINE HYBRIDIZATION USING CHROMATOGRAPHY AND GEOGRAPHIC INFORMATION SYSTEMS: A CASE STUDY IN EAST TEXAS

    … individuals). Through HPLC, 14 chromatogram peaks were identified and measured for intensity. T-Tests for overstory and advanced regeneration at each site indicated no significant differences for peak intensity between forest strata. Two-way ANOVA indicated the significance of six peaks for …

    sfasu Repository record for AN ANALYSIS OF LOBLOLLY PINE AND SHORTLEAF PINE HYBRIDIZATION USING CHROMATOGRAPHY AND GEOGRAPHIC INFORMATION SYSTEMS: A CASE STUDY IN EAST TEXAS (opens in a new tab)

  13. Diagnostische Genauigkeit der Perfusionsanalyse am Skelettmuskel mit kontrastunterstütztem Ultraschall und ihr Einsatz bei Diabetes mellitus

    … wurden neue Messparameter, nämlich wash-out und peak intensity, auf ihre Anwendbarkeit hin <br>überprüft und mit der etablierten Messgröße TTP verglichen. Weiterhin wurde der Einfluss von Größe und Positionierung der regions of interest (ROI) an Einzelfällen untersucht. <br>Hinsichtlich der …

    freiburg-diss Repository record for Diagnostische Genauigkeit der Perfusionsanalyse am Skelettmuskel mit kontrastunterstütztem Ultraschall und ihr Einsatz bei Diabetes mellitus (opens in a new tab)

  14. Femtosecond pulsed laser deposition

    … to ablate the target has a significantly higher peak intensity and shorter pulse duration as compared to conventional nanosecond lasers more commonly used for PLD. Experiments have been conducted on the growth of Nd:Gd is presented. Experimental results will show the composition and lattice …

    soton Download PDF for Femtosecond pulsed laser deposition (opens in a new tab)

  15. A 2-D model for the O'Connell effect in W Ursae Majoris systems /

    … by calculating the magnitude difference of the peak intensity at each of the light curve maxima. These asymmetries are usually modeled with ad hoc spots, usually considered as magneto-hydrodynamic in origin. The work of Zhou and Leung offers a thermodynamically motivated solution for these light …

    oklahoma-thes Repository record for A 2-D model for the O'Connell effect in W Ursae Majoris systems / (opens in a new tab)

  16. Statistical photoionization theory of atoms in soft XUV free-electron laser fields

    … of the field’s coherence temporal length and peak intensity. Particularly, the photoionization of helium (He) and lithium ion (Li+ ) via their doubly-excited state 2s2p 1 P has been studied with the interacting FEL’s 1st-order coherence function modelled as square-exponentially dependent. The …

    dcu Download PDF for Statistical photoionization theory of atoms in soft XUV free-electron laser fields (opens in a new tab)

  17. A Temporal Examination of the Connections between Convective Available Potential Energy and Convective System Development

    … between realization of maximum CAPE and the peak intensity of nearby convection, and at what local time of day each of these occurrences takes place. This study specifically explores the diurnal variations in CAPE in the continental United States (also known as the CONUS) in seasons of …

    cuny Repository record for A Temporal Examination of the Connections between Convective Available Potential Energy and Convective System Development (opens in a new tab)

  18. A resonance electronic raman effect

    … exciting frequencies. A strong electronic peak corresponding to a transition within the 7F6 manifold was observed at 84 cm^-1. The dependence of the electronic peak intensity on exciting frequency was investigated by comparison with the phonon modes at 139 cm^-1 and 266.8 cm^-1, the latter …

    carleton Repository record for A resonance electronic raman effect (opens in a new tab)

Page 1 of 15