Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 18 of 18 for “"Peak current-mode control"”
-
Evolution of current mode control approaches for implementation in rapid capacitor charger technology
… power management parameters to these systems. Current mode control is seen as a desirable control method for the power inverter to quickly charge the capacitor bank. An analog current mode control platform has been demonstrated at the P3E (pulsed power and power electronics) Laboratory. …
-
Analysis and Comparison of Popular Models for Current-Mode Control of Switch Mode Power Supplies
Current-mode control is the most popular scheme used for the operation of SMPS (Switch Mode Power Supplies). Current-mode control, also known as current-programmed mode or current-injected control is a multi-loop control scheme that has an inner loop and an outer voltage loop. The current loop …
-
Control And Topology Improvements In Half-bridge Dc-dc Converters
… requirements for DC-DC converters. Topology and control are two key topics in this dissertation. A variety of techniques for DC-DC converter performance improvement are presented in this work. Focusing on the efficiency issue, a variety of clamping techniques including both active and passive …
-
Design and Development of High-Frequency Switching Amplifiers Used for Smart Material Actuators With Current Mode Control
… is hysteretic with respect to its electrical control signal. This actuator's reactive load property usually causes a large portion of reactive power circulating between the power amplifier and the driven actuator, thus reduces the circuit efficiency in a linear power amplifier scenario. In …
-
Average current-mode control and charge control for PWM converters
Two control schemes for PWM converters, average current-mode (ACM) control and charge control, are studied in this dissertation. The small-signal models are derived for continuous-conduction mode PWM converters employing these two controls. Sampled-data modeling is applied to the current loop …
-
Current-Mode Control: Modeling and its Digital Application
Due to unique characteristics, current-mode control architectures with different implementation approaches have been widely used in power converter design to achieve current sharing, AVP control, and light-load efficiency improvement. Therefore, an accurate model for current-mode control is …
-
High performance control of VRM circuits
… because of its ability to handle large load current and to achieve fast dynamic transient response under large step-load condition.The first part of this thesis fully investigates this issue for three popular control schemes used currently: Voltage Mode Control (VMC), Average Current Mode …
-
A line and load independent zero voltage switching DC/DC full bridge converter topology
… blocking capacitor is essential to prevent the current sense transformer from saturation, and the study of this thesis shows that contrary to the conventional pulse width modulated full bridge converter, the peak current mode control can still be used along with the blocking capacitor in a phase …
-
True-Average Current-Mode Control of DC-DC Power Converters: Analysis, Design, andCharacterization
… the converter components, a robust closed-loop modeling is very essential for reliable power-electronic systems.Two closed-loop control techniques for power converters exist: voltage-mode control and current-mode control. The principles of voltage-mode control have been explored in great depths …
-
Improved Models for DC-DC Converters
To obtain high performance control of a dc-dc converter, a good model of the converter is needed. It is suitable to consider the load to be included in the converter model since it usually affects the dynamics. The load is often the most variable part of this system. If the load current and the …
-
Design of robust controllers for telecom power supplies
… power supply is studied and analyzed from control system viewpoint. It consists of three stages: AC/DC rectifier, a backup battery, and a Telecom load. The AC/DC rectifier stage can be composed of paralleled DC/DC converters preceded by paralleled AC/DC converters. However, paralleled DC/DC …
-
Relative Stability of the Inner-Current Loop of Peak Current-Mode Controlled PWM DC-DC Converters in CCM
<p>Current-mode control is a commonly adopted method of regulation for pulse-width modulated (PWM) dc-dc power converters in industry, but is not well understood. The advantages of current-mode control over the voltage-mode control include inherent overload and short circuit protection, faster …
-
DC-DC Converters - Dynamic Model Design and Experimental Verification
To obtain high performance control of a dc-dc converter, a good model of the converter is needed. The load usually affects the dynamics and one way to take this into consideration is to regard the load as a part of the converter. The load is often the most variable part of this system. If the load …
-
Modeling of V2 Control with Composite Capacitors and Average Current Mode Control
Various types of current mode control are being used in different applications. Model for current mode control is indispensable for proper system design. Since 1980s, modeling of current mode control has been a hot topic in power electronics field. In current mode control, sub-harmonic oscillation …
-
Pulse Frequency Modulation Zcs Flyback Converter In Inverter Applications
… has two stages cascaded, which has simpler controller but low efficiency. A new solar-based single-stage grid-connected inverter system can achieve higher efficiency by reducing the power semiconductor switching loss and output stable and synchronizing sinusoid current into the utility grid. …
-
Fuel Cell Distributed Generation: Power Conditioning, Control and Energy Management
… examined. The selected converter is first modeled to gain insight into its behavior for the purpose of designing suitable compensators. MATLAB is then used to study the results using the frequency domain, and it was observed that the converter offers its own unique challenges in terms of …
-
Evaluation of boost converter and single phase inverter circuit efficiency improvement using silicon carbide devices and IGBTs
… and standalone photovoltaic system. The dynamic modelling of boost converter was derived based on State-Space Average Model. It can be depicted from the control-to-voltage transfer function that there was no RHP zero in case of discontinuous conduction mode of boost converter which resembled …
-
Spínaný zdroj s digitální řídící smyčkou
Diplomová práce seznamuje s funkcí jednočinného propustného měniče. Zabývá se detailním vysvětlením funkce jednočinného propustného měniče s demagnetizačním vinutím a jednočinného můstkového propustného měniče. Popisuje chování propustných měničů v režimu spojitých a přerušovaných proudů. …