Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"Peak demand reduction"”.
-
Using Hydrated Salt Phase Change Materials for Residential Air Conditioning Peak Demand Reduction and Energy Conservation in Coastal and Transitional Climates in the State of California
… climates. This fact makes that the electric peak demand be dominated by air conditioning use of residential buildings in the summer time. This extra peak demand caused by the use of air conditioning equipment lasts only a few days out of the year. As a result, unavoidable power outages have …
-
An Expert-based Approach for Grid Peak Demand Curtailment using HVAC Thermostat Setpoint Interventions in Commercial Buildings
… dissertation explores the idea of inducing grid peak demand curtailment by turning commercial buildings into interactive assets for building owners during the demand control period. The work presented here is useful for both ab initio design of new sites and for existing or retrofitted sites. An …
-
Consumer savings and peak reduction potential of a simulated residential microgrid with demand response and electric vehicle discharge capabilities
… consumers have a large potential for utility peak demand reduction. As more homeowners acquire solar generation capacity and electric vehicles, the variable demand on the grid becomes more concerning while the potential for localized load smoothing grows. This thesis models possible outcomes …
-
The Investigation and Optimization of a Two-Heat-Pump System Incorporating Thermal Storage for Shaping Residential Heating Load
… energy consumption from generation to provide peak demand reduction and to better facilitate the integration of variable renewable energy resources. A scoping study was performed to evaluate the potential impact of this project if implemented in single family homes in Portland, Oregon. This …
-
Comparing Economic, Environmental, and Social Effects of Central Air Conditioner Size and Thermostat Schedule Interactions
… but also to utilities as a contributor to peak demand and to society by the resultant carbon dioxide and other emissions. In this article, we investigate how size and operational patterns of central residential air conditioners interact with stakeholder benefits and costs. The case study …
-
Integrating complex human dimensions into residential demand flexibility program design
… over 135 million customers contributes 48% of peak energy demand and about 1 billion tons of carbon emissions. Peak energy demand reduction via demand flexibility (DF) is critical to increasing grid-integrated renewable energy and reducing carbon emissions. Yet, DF does not meet its peak demand …
-
Investigation of Inorganic Salt Hydrate Phase Change Materials for Thermal Energy Storage Integrated into Heat Pump Systems
… to the highest potential for energy savings and peak demand reduction. This HP-TES system was then modeled in a building thermal energy simulation where the same findings emerge: a TES temperature near the application temperature shows the highest potential. A common method of achieving an …
-
Dynamic modeling, optimization, and control of integrated energy systems in a smart grid environment
… optimization strategies are able to reduce peak demand and decrease cooling electricity costs by 79%. Smart grid data are employed to consider a system of 900 residential homes in Austin. In order to make the system model tractable for a model predictive controller, a reduced-order home …
-
Optimal Siting and Sizing of Solar Photovoltaic Distributed Generation to Minimize Loss, Present Value of Future Asset Upgrades and Peak Demand Costs on a Real Distribution Feeder
… transmission and distribution levels, meeting demand growth and improving distribution network performance and security. DG technology is rapidly maturing in Ontario due to government economic incentives promoting connection, specifically, the Ontario’s Feed-In-Tariff (FIT) Program. Optimal …
-
Energy Management System of Hybrid Wayside Storage in Urban Railway Traction
… which leads to both energy savings and peak demand reduction.
-
Improvement and optimization of laboratory exhaust systems
… level when the building airflow changes. The fan peak demand reduction is 49% and the fan energy savings is 55% compared to the original system. The project payback period is 3.7 years. Moreover, the duct static pressure is reduced to a reasonable level, which provides fume hoods with the required …
-
Green Scheduling of Control Systems
Electricity usage under peak load conditions can cause issues such as reduced power quality and power outages. For this reason, commercial electricity customers are often subject to demand-based pricing, which charges very high prices for peak electricity demand. Consequently, reducing peaks in …
-
The role of the forward capacity market in promoting electricity use reduction
<p>Electricity use reduction is at the heart of an energy policy landscape increasingly defined by climate change, security and affordability. With its potential of peak demand reduction, it can be used as a cost-effective alternative to generation for contributing to capacity adequacy. In many …
-
Multi-Dimensional Energy Consumption Scheduling for Event Based Demand Response
The global energy demand in residential sector is increasing steadily every year due to advancement in technologies. The present electricity grid is designed to support peak demand rather than Peak to Average (PAR) demand. Utilities are investigating the residential Demand Response (DR) to lower …
-
What Drives Residential Energy Demand? An Investigation of Smart Metered Electricity Data
… Grid Smart City project to build a residential demand modelling tool set. This data covers a part of greater Sydney. Two statistical models for household annual electricity demand and half-hourly peak electricity demand were established and tested for both individual households and regional …
-
Data-Driven Optimized Operation of Buildings with Intermittent Renewables and Application to a Net-Zero Energy Library
… can be an open-market electrical price or a demand response signal thus improving the grid's flexibility while satisfying the building constraints and better utilizing its systems and storage. In a morning peak demand reduction case, given at least a 4-hour notice, our method is able to …
-
Evaluating Photovoltaics in a Peak-Shaving Supply Management Role in Rural Communities
… ± 0.13 m. Building sidewall, side entrance and peak heights ranged from 1.9 to 5.6 m and the mean error was 0.06 ± 0.04 m, or 1.2% mean error. The results proved that using consumer-grade UAV’s and photogrammetric SfM could create accurate DSM and orthomosaics of a study area at efficient use of …
-
An experimental and numerical investigation of predictive control with different building-integrated thermal storage systems
… thermal mass of a space in order to reduce the peak demand and energy consumption while maintaining occupant comfort. Two case studies are performed together with model development. The first one is a zone of a perimeter office with floor heating, convective cooling and a carpeted concrete …
-
Optimal Deployment of Energy Storage Technologies for Grid Service Provision and Microgrid Formulation
… Operating Reserve (OR), and Capacity Markets Demand Response (CMDR). Results indicate that while AA-CAES is economically viable for EA and OR primarily in high-variability markets, it remains highly profitable for CMDR across both stable and variable pricing markets. At the consumer level, the …
-
Peak Load Shaving Using Battery Energy Storage Systems for a Regional Distribution Network
… (RDNs) frequently encounter challenges during peak load periods, including elevated infrastructure costs, grid congestion and instability, higher fuel consumption, environmental pressures, increased transmission and distribution losses, and reduced system efficiency. These issues arise from …
Page 1 of 2