Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Peak detector"”.

  1. A low power, low noise heart variability sensor design

    … Amplifier in this project. A d/dt peak detector is used to find the peaks of the heart beats. Low power, low noise heart variability sensors can look for patterns in a patient’s heart beat which can be correlated to known patterns for certain diseases. This can help doctors …

    texas Repository record for A low power, low noise heart variability sensor design (opens in a new tab)

  2. Design of an adaptive cable equalizer using 0.5 [mu]m [i.e. micrometer] CMOS process

    … of the cable will be estimated through the peak detector circuitry and the equalizer filter will be tuned automatically according to the estimated cable length using this linearity. All the circuits of the system have been designed using AMI 0.5µm CMOS technology and simulated on Cadence's …

    ut-knoxville Repository record for Design of an adaptive cable equalizer using 0.5 [mu]m [i.e. micrometer] CMOS process (opens in a new tab)

  3. A Novel Analog-Based Matched Filter Design

    … The gain-boosted N-path filter has a measured peak passband S21 of 10 dB, a maximum out-of-band attenuation of -50 dB, and a tunable passband between 0.4-3.0 MHz. Then, the switchable bandwidth gain boosted N-path filter has measured bandwidths below the kHz range with quality factors from …

    carleton Repository record for A Novel Analog-Based Matched Filter Design (opens in a new tab)

  4. Impedance Spectroscopy Systems Suitable for Biomedical Cell Impedance Measurement

    … utilizes a time-to-digital converter (TDC) and a peak detector circuit (PDC) for quick measurement of both impedance phase and magnitude, respectively. Designed in a 0.18μm CMOS process, the front-end is capable of performing impedance measurements in 6μs at frequencies ranging from 100Hz-10MHz …

    tamu Repository record for Impedance Spectroscopy Systems Suitable for Biomedical Cell Impedance Measurement (opens in a new tab)

  5. Design and self-calibration scheme for RF circuits using mems in 3D packages

    … (NF). On-chip testing is performed using a peak detector and a digital signal processor (DSP). A low-cost self-calibration scheme is proposed which utilizes a tuning circuit consisting of an inductor and capacitor bank and a MEMS switch matrix. The MEMS switch matrix and the analog circuitry …

    alabama Repository record for Design and self-calibration scheme for RF circuits using mems in 3D packages (opens in a new tab)

  6. A study of time-based features and regularity of manipulation to improve the detection of eating activity periods during free living

    … an algorithm for automatically detecting peaks in activities associated with food preparation and clean-up. This peak detector is then used for segmenting data. These segments are then classified as eating or non-eating activities using a naive Bayes classifier based on probabilities …

    clemson Repository record for A study of time-based features and regularity of manipulation to improve the detection of eating activity periods during free living (opens in a new tab)

  7. On the Stability of Region Count in the Parameter Space of Image Analysis Methods

    … region count. The experiments are using flower detector, peak detector and retinal image lesion detector respectively to process images and signals. The results from these experiments all suggest that our computer vision framework can solve different image and signal problems and provide …

    clemson Repository record for On the Stability of Region Count in the Parameter Space of Image Analysis Methods (opens in a new tab)

  8. Derivation of the respiratory rate signal from a single lead ECG

    … derived respiration program, develop an adaptive peak detector algorithm to process the complex respiration signal and produce a usable respiration rate waveform. Three methods for deriving respiration from a single lead ECG were identified and implemented in LabVIEW. The three methods were R wave …

    njit Repository record for Derivation of the respiratory rate signal from a single lead ECG (opens in a new tab)

  9. A Self-Calibrated Power Detector and Current Sensor for Use in a Power Amplifier Control Circuit

    … loop: a DC bias current sensor and a power detector. The DC bias current sensor must accurately measure the DC bias of the power amplifier since this current is used to calculate the DC power dissipation for the power-added efficiency. In order to ensure the DC current sensor’s output is …

    tamu Repository record for A Self-Calibrated Power Detector and Current Sensor for Use in a Power Amplifier Control Circuit (opens in a new tab)

  10. Integrated Circuit Design for Silicon Photonics Interconnects

    … on microring drop filters and waveguide photodetectors implemented in a 130nm SOI process and high-speed optical front-ends designed in 65nm CMOS. When tested with a waveguide photodetector with 0.45A/W responsivity, the receiver achieves -8.0 dBm OMA sensitivity at a BER=10-12 with a jitter …

    tamu Repository record for Integrated Circuit Design for Silicon Photonics Interconnects (opens in a new tab)

  11. Development of Electronic Instrumentation For Computer-Assisted Surgery

    … on is required. Two AC current sensors, two peak detector circuits, and one voltage comparator circuit were used to detect when an electromagnetically tracked electrosurgical cauterizer is being powered on and differentiate between the cut and coagulation modes when cauterizing different …

    queens Repository record for Development of Electronic Instrumentation For Computer-Assisted Surgery (opens in a new tab)

  12. Analysis and Design of a Wave-Interference Based Monolithic Millimeter-Wave Backscatter Interrogator

    … frequency divider chain, the demodulating peak detector, as well as the baseband signal processing are described in detail. A high-input-voltage-tolerant millimeter-wave voltage peak detector is implemented below a transmission line and it employs thick gate-oxide, high-voltage transistors …

    qucosa-diss

  13. Profilér infračerveného laserového paprsku

    Tato diplomová práce se zabývá návrhem profiléru infračerveného laserového paprsku, který umožňuje kalibraci směru a grafické zobrazení jeho Gaussova rozložení. Práce je zaměřena na výběr vhodného detekčního prvku, návrh analogové části, která je citlivá na okolní rušení, zpracování krátkých a …

    brno-tech Repository record for Profilér infračerveného laserového paprsku (opens in a new tab)

  14. Enhancing AR Letterboards for Nonspeaking Autistic People via Haptic Feedback and Intent Inference

    Many nonspeaking autistic individuals (nonspeakers) rely on letterboards to communicate by pointing to letters to spell words. This approach has enabled many to express thoughts and participate more fully in daily life. However, learning to use a letterboard requires years of consistent practice …

    calgary Repository record for Enhancing AR Letterboards for Nonspeaking Autistic People via Haptic Feedback and Intent Inference (opens in a new tab)

  15. Design of portable CMOS NMR system

    … alignment of two clocks is proposed. The phase detector circuit triggers the on-chip timer that controls the NMR operation. This way, the output phase can remain constant. Second, the slow settling of the receiver deteriorates the acquisition sensitivity. This problem is solved with the proposed …

    texas Repository record for Design of portable CMOS NMR system (opens in a new tab)

  16. Návrh a realizace modernizované řídicí elektroniky autonomního podvozku

    Tato bakalářská práce je zaměřená na návrh modernizované řídicí elektroniky, jež má na starosti napájení, snímání a zpracování dat a poskytování spolehlivé komunikace mezi vyšší řídicí vrstvou a nízkoúrovňovými součástkami. V rešeršní části je popsána analýza stávajícího stavu hardwaru a firmwaru. …

    brno-tech Repository record for Návrh a realizace modernizované řídicí elektroniky autonomního podvozku (opens in a new tab)

  17. Nízkofrekvenční aktivní bezprahové napěťové detektory

    Tato bakalářská práce se zabývá různými řešeními aktivní topologie napěťových detektorů a usměrňovačů nevyužívajících diody. Konkrétně se zaměřuje na diskrétní detektory s násobičkami a převodníky napětí na proud, diskrétní špičkový detektor s transkonduktory a integrovaný RMS detektor s násobičkou …

    brno-tech Repository record for Nízkofrekvenční aktivní bezprahové napěťové detektory (opens in a new tab)

  18. Detekce fibrilace síní zPPG signálu

    … vlastního algoritmu pro detekci systolických peaků v PPG a vývoji algoritmu pro detekci fibrilace síní z PPG. Výsledkem praktické části práce je funkční klasifikační algoritmus, který je schopen rozřadit data do dvou skupin – signály obsahující sinusový rytmus a signály obsahující fibrilaci …

    brno-tech Repository record for Detekce fibrilace síní zPPG signálu (opens in a new tab)

  19. Evaluation of Pedometer Performance Across Multiple Gait Types Using Video for Ground Truth

    … on three different methods of step detection; peak detection, zero crossing (threshold based), and autocorrelation. The evaluation of these algorithms was performed across 5 dimensions, including algorithm, parameter set, gait type, sensor position, and evaluation metric, which yielded 108 …

    clemson Repository record for Evaluation of Pedometer Performance Across Multiple Gait Types Using Video for Ground Truth (opens in a new tab)

  20. Systém pro měření četnosti amplitud pulzů

    Zařízení pro měření četnosti amplitud pulzů na jeho vstupu bylo navrženo, realizováno a otestováno. Projekt zahrnoval návrh a realizaci hardwarové části za použití moderních mikrokontrolérů a jednoduchý software pro obsluhu zařízení. Důraz byl kladen na uživatelskou přívětivost, jednoduchou …

    brno-tech Repository record for Systém pro měření četnosti amplitud pulzů (opens in a new tab)

Page 1 of 2