Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 109 for “"Peak shape"”

  1. Mass analysis with quadrupoles with added multipole fields

    … and resolution are low, and there is peak structure. When a<0, only very low resolution (80) and transmission are seen. With both a>0 and a<0, the use of islands of stability for mass analysis greatly improves peak shape, resolution, and in some cases, transmission. Mass selective …

    ubc Repository record for Mass analysis with quadrupoles with added multipole fields (opens in a new tab)

  2. Instrumentation and Kinetic Studies of Surface-Induced Dissociation in a Time-of-Flight Mass Spectrometer

    … (Chapters 3 and 4). Theoretical and experimental peak shape comparisons assuming unimolecular decay kinetics indicated a log rate constant in the range 6 - 7 (Chapter 4). Energy and mass resolved kinetic studies are also carried out. The contribution of special structural features to peptide …

    arizona-thes Repository record for Instrumentation and Kinetic Studies of Surface-Induced Dissociation in a Time-of-Flight Mass Spectrometer (opens in a new tab)

  3. Real time automation for batch sampling analysis

    … sample management capability, the use of peak shape recognition for detection, calibration, and a comprehensive interactive command capability. Discussion of system performance and recommendations for future improvements are included.

    vt Repository record for Real time automation for batch sampling analysis (opens in a new tab)

  4. STUDIES OF ION DISSOCIATION KINETICS AND MECHANISMS BY SURFACE-INDUCED DISSOCIATION AND INFRARED MULTI-PHOTON DISSOCIATION/SOFT-LANDING

    … dissociation (SID) capability and peak shape analysis. Structural studies were performed to determine dissociation mechanisms. The b₂⁺ ion from AGG is an oxazolone structure as indicated by the IRMPD spectrum and quantum chemical calculations. Protonated …

    arizona-thes Repository record for STUDIES OF ION DISSOCIATION KINETICS AND MECHANISMS BY SURFACE-INDUCED DISSOCIATION AND INFRARED MULTI-PHOTON DISSOCIATION/SOFT-LANDING (opens in a new tab)

  5. Effects of Static and Dynamic Thermal Gradients in Gas Chromatography

    … Transport model simulated retention times and peak widths matched experimental values well for isothermal, temperature programmed and thermal gradient separations. The validated transport model was used to study the effect of static (not varying temporally) thermal gradients on GC separations …

    byu Repository record for Effects of Static and Dynamic Thermal Gradients in Gas Chromatography (opens in a new tab)

  6. Methylammonium Formate as a Mobile Phase Modifier for Reversed Phase Liquid Chromatography

    … is a good silanol suppressor resulting in better peak shape and separation efficiency than methanol as a mobile phase modifier when using C18-based silica columns. The preliminary studies using MAF as a mobile phase modifier or additive for pharmaceutical applications using LC-MS methods have …

    ohiolink Repository record for Methylammonium Formate as a Mobile Phase Modifier for Reversed Phase Liquid Chromatography (opens in a new tab)

  7. Characterizing Subsurface Sediments with Passive Microtremor Measurements Using the Horizontal-to-Vertical Spectral Ratio (HVSR) Method in the South Nation Watershed in Embrun, Ontario

    … the correlation between H/V resonance peak shape, fundamental frequency and lithological succession by applying a machine learning clustering algorithm. Clusters are linked to specific lithologies through signals from borehole locations where the subsurface is known. Two profiles across …

    carleton Repository record for Characterizing Subsurface Sediments with Passive Microtremor Measurements Using the Horizontal-to-Vertical Spectral Ratio (HVSR) Method in the South Nation Watershed in Embrun, Ontario (opens in a new tab)

  8. The Determination of Lead and Cadmium in Tobacco Using High Performance Liquid Chromatography and Dithiocarbamate Derivitization.

    … the presence of hazardous solvents to optimize peak shape and resolution; the mobile phase consists of methanol, water, and a surfactant. Tobacco samples were chemically oxidized and reacted with sodium diethyldithiocarbamate reagent prior to analysis using the HPLC method. The lead …

    etsu Repository record for The Determination of Lead and Cadmium in Tobacco Using High Performance Liquid Chromatography and Dithiocarbamate Derivitization. (opens in a new tab)

  9. Immature SOD1: protein folding, misfolding and aggregation

    … and nitrogen temperature coefficients, and peak shape analysis. These results provide new evidence that ALS-associated mutations promote the aggregation of apoSH SOD1 through multiple pathways and potentially through subtle differences in local structure and dynamics with broad implications …

    waterloo Repository record for Immature SOD1: protein folding, misfolding and aggregation (opens in a new tab)

  10. Supercritical fluid chromatography and two-dimensional liquid chromatography : From new applications to technical innovations

    … chromatography often lead to poor separation and peak shape, due to strong solvent effect and viscous fingering. Multiple injection technique was investigated in this PhD study to enable the injection of relatively large volume to enhance the detectability. The signal-to-noise ratio enhancement …

    lund Repository record for Supercritical fluid chromatography and two-dimensional liquid chromatography : From new applications to technical innovations (opens in a new tab)

  11. Spray ILGAR growth and Raman spectroscopy of CuInS2 thin films

    … amorphous carbon. Additionally, the asymmetric peak shape of the Raman A1 mode of chalcopyrite-type CuInS2 thin films was analyzed. The peak shape was simulated numerically according to the phonon confinement model. These simulations yielded values for the average distances between …

    fu-berlin Repository record for Spray ILGAR growth and Raman spectroscopy of CuInS2 thin films (opens in a new tab)

  12. Platinum oxide reduction kinetics on polycrystalline platinum electrodes

    … assembled analog instrumentation. The reduction peak was studied under three surface conditions: same oxide coverage θ and same potential E, different θ and same E, and same θ but different E, to determine the influence of θ and E on the peak potential and peak shape. The double-layer charge …

    uvic Repository record for Platinum oxide reduction kinetics on polycrystalline platinum electrodes (opens in a new tab)

  13. Kolonėlės perkrovos efektai atvirkščių fazių ir hidrofilinės sąveikos skysčių chromatografijoje /

    … benzoate and nicotine retention time and peak shape was tested under certain experiment terms (pH, temperature, buffer concentration and solvent volume) and compared. It was evaluated, that under neutral pH BEH HILIC column‘s capacity, depending on the nature of the analyte, is 5 – 20 …

    vilnius Repository record for Kolonėlės perkrovos efektai atvirkščių fazių ir hidrofilinės sąveikos skysčių chromatografijoje / (opens in a new tab)

  14. Reversed-phase and surfactant modified reversed-phase high and ultra-high performance liquid chromatography of phenolic and aliphatic carboxylic acids

    … however, Tween 20 shows faster and better peak shape than Tween 40. MLC using Tween 20 was used successfully to analyze red wine, spiked and unspiked, for seven of the cinnamic acids; the results showed excellent recoveries for the spiked sample.To the best of our knowledge, amino …

    ohiolink Repository record for Reversed-phase and surfactant modified reversed-phase high and ultra-high performance liquid chromatography of phenolic and aliphatic carboxylic acids (opens in a new tab)

  15. Phase separation in solid mixtures of helium-3 and helium-4

    … of changes in the x-ray lattice parameter and peak shape. A new rigid tail dilution refrigerator cryostat is used to study 3 He-4He crystals with 3He concentrations of 0.10,0.20,0.30,0.45,0.60 and 0.70, and melting pressures between 3.0 and 4.3 MPa. The phase separation temperatures determined …

    uiuc Repository record for Phase separation in solid mixtures of helium-3 and helium-4 (opens in a new tab)

  16. An inverse gas-solid chromatographic study of the adsorption heterogeneity of aluminum oxide powders used in ceramic processing

    … and relationship between the chromatographic peak shape and the adsorption isotherm is presented. A new method for determination of the adsorption energy distribution function, which is applicable to any convex upwards adsorption isotherm, has been developed. This robust and accurate method …

    utk-theses Repository record for An inverse gas-solid chromatographic study of the adsorption heterogeneity of aluminum oxide powders used in ceramic processing (opens in a new tab)

  17. Investigations on the Effects of Hydrothermal Surface Doping of Europium Ions on Titanium Dioxide Nanoparticles

    … were observed in the oxygen and titanium XPS peaks, both in location in energy and overall peak shape, as the temperature of the hydrothermal environment changed. In addition, it was inferred from XPS and photoluminescence (PL) spectroscopy that there was healing (i.e., reduction) of the …

    mo-state Repository record for Investigations on the Effects of Hydrothermal Surface Doping of Europium Ions on Titanium Dioxide Nanoparticles (opens in a new tab)

  18. Theoretical and Practical Aspects of a Flame Atomic Fluorescence Detector for Liquid Chromatography

    … based on this separation is presented. The peak shapes of the system are described in terms of two models. These models examine the physical and chemical processes of the detector and how these processes affect the peak shape. Computer simulations are used to fit experimental data to the …

    marquette Repository record for Theoretical and Practical Aspects of a Flame Atomic Fluorescence Detector for Liquid Chromatography (opens in a new tab)

  19. Machine Learning for Structure-Agnostic Chemical Analysis from Chromatographic Data

    … can be inferred directly from chromatographic peak shape, bypassing manual peak integration. ML classification and regression models trained on peaks from ambient atmospheric samples achieve 89% identification accuracy and a mean absolute error of 0.085 ppbv in concentration prediction. …

    vt Repository record for Machine Learning for Structure-Agnostic Chemical Analysis from Chromatographic Data (opens in a new tab)

  20. INVESTIGATION OF SITE-SPECIFIC CHANGES WITHIN THE N-TERMINAL DOMAIN OF CALMODULIN AND THE RELATIONSHIP TO STRUCTURAL AND THERMAL STABILITY

    … changes in dynamics was derived from changes in peak shape and chemical shift position to elucidate how the solution environment affects residues within N-CaM. 1H-15N HSQC experiments provided quantitative determination of specific residues near known degradation sites that undergo physical …

    ku Repository record for INVESTIGATION OF SITE-SPECIFIC CHANGES WITHIN THE N-TERMINAL DOMAIN OF CALMODULIN AND THE RELATIONSHIP TO STRUCTURAL AND THERMAL STABILITY (opens in a new tab)

Page 1 of 6