Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"Pediatric Phantoms"”
-
Mathematical descriptions of a one and five-year old child for use in dosimetric calculations
… dose which may be introduced in using shrunken phantoms, two pediatric phantoms were developed.</p><p>Mathematical representations of a one-year old and a five-year old human have been designed. The phantoms consist of head, trunk and leg regions with a skeletal system and twenty-two internal …
-
Estudo dosimétrico de SAF e dose absorvida por atividade injetada de radiofármacos utilizando fantomas computacionais
… and computer simulations using several voxelized phantoms and the Monte Carlo code EGSnrc. Guidelines for producing SAF values were defined by OpenDose and the results are published at the website of MCMEG. The S-values, absorbed dose and effective dose per injected activity were calculated for …
-
Task-based Optimization of Administered Activity for Pediatric Renal SPECT Imaging
… database uses a highly-realistic population of pediatric phantoms with anatomical and body morphological variations. Using the developed projection image database, we have explored patient factors that affect IQ and are currently in the process of determining relationships between IQ and AA in …
-
Προσομοίωση των εξετάσεων υπολογιστικού τομογράφου σε παιδιά με τη μέθοδο monte carlo, για την εκτίμηση της απορροφούμενης δόσης ακτινοβολίας
… dose and organ dose (thyroid and eye lens) for pediatric patients (neonate, 1, 5, 10 and 15 years old). Method: The Monte Carlo (MC) code MCNP was employed to simulate CT exposures. To verify MC results dose measurements were carried out on physical pediatric phantoms using TLD’s. For the …
-
Dose and Risk Assessment Methods for Epidemiologic Studies Investigating Long-term Side Effects of Proton Therapy
… of body size-dependent computational human phantoms, methods were created to generate a full-body patient-specific phantom. This allows for full-body neutron dose calculations using Monte Carlo radiation transport methods. Second, a computer simulation model was developed to reconstruct a …
-
Radiation Dose Estimation for Pediatric Patients Undergoing Cardiac Catheterization
… common X-ray based imaging modalities. </p><p>Pediatric patients are at a greater risk compared to adults due to their greater cellular radio-sensitivities as well as longer remaining life-expectancy following the radiation exposure. In terms of radiation dosimetry, they are often more …
-
Advancement of A 3D Computational Phantom and Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies
… various computed tomography (CT)-based phantoms from the University of Florida/National Cancer Institute (UF/NCI) phantom library to arbitrary ages. We quantified the geometric accuracy of scaling by comparing several overlaps, distance, and anthropometric parameters of the scaled …