Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"Penetration force"”.

  1. Penetration force measurements in the central nervous system with silicon electrodes

    … the dimpling effect that is due to the insertion force. A method which can reduce the penetration force can also reduce dimpling and the resulting tissue damage. There are two objectives in this thesis. One is to measure the penetration force with Michigan electrodes, which are silicon based …

    njit Repository record for Penetration force measurements in the central nervous system with silicon electrodes (opens in a new tab)

  2. Burial Performance Between Different Head Shapes and Skulls Amongst Head-First Burrowing Fishes

    … or conical head shape. Head shape determines the penetration force magnitudes, but it is important for their neurocranium to avoid overwhelming cranial stresses from those burial forces. There is minimal research on the penetration force (N), rotational resistance (Nmm), and cranial stress (Pa) …

    ottawa-retro Repository record for Burial Performance Between Different Head Shapes and Skulls Amongst Head-First Burrowing Fishes (opens in a new tab)

  3. Penetration Forces for Subsurface Regolith Probes

    … and porosity can be made from the shape of the penetration curve. Using penetrometers mounted on planetary platforms could be challenging due to the uncertainty of the subsurface composition and since the maximum allowed force for penetration is the weight of the lander or rover on the surface. …

    arkansas Repository record for Penetration Forces for Subsurface Regolith Probes (opens in a new tab)

  4. Approximation of the plastic behavior of rocks at elevated mean pressures using a bi-linear yield envelope

    … the wedge indentation theory for this case, the penetration force equation is derived. The calculated values for the penetration force are then compared with the experimental results obtained by previous investigations. The rocks tested are: Danby Marble, Carthage Marble, Ohio Sandstone and …

    rice Repository record for Approximation of the plastic behavior of rocks at elevated mean pressures using a bi-linear yield envelope (opens in a new tab)

  5. Production, development, and characterization of plastic hypodermic needles

    … steel. A key issue in their acceptance is the force required to penetrate a patient; a smaller force is associated with less pain. The effect that needle parameters have on the penetration force is studied in an effort to better understand how to reduce penetration forces and increase the …

    gatech Repository record for Production, development, and characterization of plastic hypodermic needles (opens in a new tab)

  6. Quantifying the forces in stabbing incidents

    … These facts make the study of mechanics of knife penetration more relevant than ever. The aim was to quantify the penetration force needed to inflict a certain stab wound by modelling knife penetration via the Finite Element Method. Case studies of stabbing incidents were carried out to give some …

    glasgow Download PDF for Quantifying the forces in stabbing incidents (opens in a new tab)

  7. Drosophila suzukii (Matsumura) (Diptera: Drosphilidae): Risk Assessment For An Invasive Vinegar Fly In Virginia Vineyards

    … varieties. More eggs were laid in grapes as penetration force decreased. Penetration force and not skin thickness was the limiting factor for oviposition. Survivorship of eggs laid in intact grapes was analyzed and survivorship to adulthood was dependent upon variety and survivorship usually …

    vt Repository record for Drosophila suzukii (Matsumura) (Diptera: Drosphilidae): Risk Assessment For An Invasive Vinegar Fly In Virginia Vineyards (opens in a new tab)

  8. Fabrication and analysis of injection molded plastic microneedle arrays

    … by injection molding, and analysis of the penetration mechanics. Injection molding is an economical mass-production technique that may encourage widespread adoption of microneedles for drug delivery. Four polymers were injection molded into hexagonal and square patterns of between 91 and …

    gatech Repository record for Fabrication and analysis of injection molded plastic microneedle arrays (opens in a new tab)

  9. Mechanics of needle insertion and deep penetration in soft solids

    … of needle insertion and continued by deep penetration. This work describes both phenomena, in relation to material properties and needle size, with simple mechanical models and compares them against experiments. Needle insertion is characterized by physical and geometrical nonlinearities …

    ubc Repository record for Mechanics of needle insertion and deep penetration in soft solids (opens in a new tab) Download PDF for Mechanics of needle insertion and deep penetration in soft solids (opens in a new tab)

  10. Biomimetic vibroprobes for lunar and terrestrial subsurface exploration

    … to predict the deceleration rate and final penetration depth of a rigid projectile probe under perpendicular subsonic impact. The analytical model, developed based on the spherical cavity expansion theory, considers plastic and elastic stress fields by incorporating the Mohr–Coulomb failure …

    manitoba Repository record for Biomimetic vibroprobes for lunar and terrestrial subsurface exploration (opens in a new tab)

  11. Micromachined Ultrasonic Silicon Horn Actuators For Biomedical Applications: Surgical Tools, Cardiac Electrophysiological Recordings, Testicular Tubule-Size Detection And Fluid Viscosity Measurement

    … surgical microprobes are developed to reduce penetration force into biological tissues by actuating the surgical tool at its ultrasonic resonance. Silicon serves as an ideal platform for integration of a variety of microfabricated sensors on the surgical tools to monitor tissue activity. In …

    cornell Repository record for Micromachined Ultrasonic Silicon Horn Actuators For Biomedical Applications: Surgical Tools, Cardiac Electrophysiological Recordings, Testicular Tubule-Size Detection And Fluid Viscosity Measurement (opens in a new tab)

  12. Relationship between cutting parameters and bit geometry in rotary cutting

    … relationship between cutting parameters (cutting force, penetration force, specific energy, specific respirable dust) and the bit geometry parameters (angle of the bit tip, bit tip size and shape of the bit) in order to reduce the amount of specific respirable dust generated and the specific …

    wvu Repository record for Relationship between cutting parameters and bit geometry in rotary cutting (opens in a new tab)

  13. Investigation of Geometrical Effects on Microneedle Geometry for Transdermal Applications

    … for microneedle fracture and split thickness penetration force measurements. Out of plane needle array configurations (100and#956;m needle length) with intra array geometric variations including needle shape, diameter, intra-array pitch and density (1a 625) were characterized on cadaver skin …

    usf Repository record for Investigation of Geometrical Effects on Microneedle Geometry for Transdermal Applications (opens in a new tab)

  14. A Functional Suitability Assessment of Aseptically Reprocessed Bromobutyl Parenteral Packaging Components

    … including container closure integrity, needle penetration force and fragmentation. In parallel, subvisible particulate matter was assessed through USP <788> methods, as well as one orthogonal characterization technique: HIAC light obscuration, membrane microscopy, and Micro Flow Imaging, …

    ku Repository record for A Functional Suitability Assessment of Aseptically Reprocessed Bromobutyl Parenteral Packaging Components (opens in a new tab)

  15. Effects of bit geometry in multiple bit-rock interaction

    … was advanced at 0.14 in/sec of advance. Cutting force, penetration force, rate of advance and respirable dust were measured during the cutting process. Specific energy and specific dust were also calculated for each experiment.

    wvu Repository record for Effects of bit geometry in multiple bit-rock interaction (opens in a new tab)

  16. Effects of Whey Protein Concentrate, Phosphate, and Sodium Hydroxide on Texture and Acceptability of Turkey and Beef Rolls

    … program that allowed continuously collected penetration force data . at specific time intervals. Penetrometer bind strength and taste panel cohesiveness of turkey and beef rolls were highly correlated (r=0.89 and r=0.93, respectively).

    utahstate Repository record for Effects of Whey Protein Concentrate, Phosphate, and Sodium Hydroxide on Texture and Acceptability of Turkey and Beef Rolls (opens in a new tab)

  17. Changes in soil density, moisture, strength, and residue cover induced by tillage and time

    … of tillage and time on soil density, moisture, penetration resistance, and percent residue cover were evaluated under field conditions. Evidence was found that the chisel plow, the no-till, and the newly introduced paraplow tillage systems are potential soil and water conservation …

    iastate Repository record for Changes in soil density, moisture, strength, and residue cover induced by tillage and time (opens in a new tab)

  18. Vision guided automation for intra-cytoplasmic sperm injection

    … value of various injection parameters, such as force fluctuation, and penetration force on cell damages. An ultimate automation task is required in microinjection to position the randomly located biological cell within the Petri dish to the system’s field of view. The proposed technique fills a …

    birmingham Download PDF for Vision guided automation for intra-cytoplasmic sperm injection (opens in a new tab)

  19. Sewing machine, fabric and thread dynamics

    … due largely to an increase of the dynamic forces and consequently to problems such as seam pucker. In this research computer-based instrumentation and high-speed digital image and signal acquisition systems were developed to study the dynamic effects of the sewing machine, fabric and thread …

    whiterose Download PDF for Sewing machine, fabric and thread dynamics (opens in a new tab)

  20. A comparison of four objective measures of beef tenderness

    … X C H, C X CH, S X H, M A X H and L X H.</p> <p>Penetration-force values were obtained from raw muscle with the AT. Cores one-half inch in diameter, from cooked muscle were used with the WB and the Instron. Maximum-shear-force values were obtained with the WB while maximum force (IMF) and "area …

    utk-theses Repository record for A comparison of four objective measures of beef tenderness (opens in a new tab)

Page 1 of 2