Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 69 for “"Penning trap"”.

  1. A novel, multiple-electrode penning trap

    … and tested an extended-length, harmonic Penning-type ion trap. A distributed-electrode design allows the radial inside dimension to be kept at a minimum (1 $cm$) while extending the axial length to 15 $cm$. In-flight capture of 10-$keV$ protons from a continuous-beam ion source has been …

    rice Repository record for A novel, multiple-electrode penning trap (opens in a new tab)

  2. A Compact, Reconfigurable Penning Trap for Quantum Applications

    Penning ion traps are versatile tools for studying atomic and molecular physics. They use static electric and magnetic fields to confine charged particles in 3-dimensional space. Most Penning traps employ a magnetic field produced by a large superconducting coil. However, in this thesis I detail …

    gatech Repository record for A Compact, Reconfigurable Penning Trap for Quantum Applications (opens in a new tab)

  3. Penning trap mass measurements to test three-body forces in atomic nuclei

    … of ²⁰'²¹Mg, ⁵¹'⁵²Ca, and ⁵¹K with the TITAN Penning trap mass spectrometer. The measured mass excesses were ME(²⁰Mg) = 17477.7(18) keV, ME(²¹Mg) = 10903.85(74) keV, ME(⁵¹Ca) = 36339(23) keV, ME(⁵²Ca) = 34245(61) keV, and ME(⁵¹K) = 22516(13) keV. With the calcium and potassium mass …

    ubc Repository record for Penning trap mass measurements to test three-body forces in atomic nuclei (opens in a new tab) Download PDF for Penning trap mass measurements to test three-body forces in atomic nuclei (opens in a new tab)

  4. Novel permanent-magnet Penning trap for studies of dipole-bound negative ions

    … ions. Here we describe a novel permanent-magnet Penning trap designed to examine the lifetime of such long lived metastable negative ions. With the help of ion trajectory calculations, the characteristics of the trap have been investigated and the most effective methods for ion injection have …

    rice Repository record for Novel permanent-magnet Penning trap for studies of dipole-bound negative ions (opens in a new tab)

  5. First measurements of atomic masses with the Canadian Penning Trap, CPT, mass spectrometer

    The Canadian Penning Trap (CPT) mass spectrometer has been set up at the ATLAS facility of the Argonne National Laboratories. The CPT mass spectrometer consists of two major components: a Paul trap for cooling and accumulation, and a Penning trap for precise mass measurements. The mass measurement …

    manitoba Repository record for First measurements of atomic masses with the Canadian Penning Trap, CPT, mass spectrometer (opens in a new tab)

  6. Resurrecting the N = 20 shell closure and upgrades to the TITAN measurement Penning trap

    … developments and improvements to the Measurement Penning Trap (MPET). The Penning trap, an experimental apparatus that uses electric and magnetic fields to determine the atomic mass through the ion’s cyclotron frequency, has been upgraded to operate at cryogenic temperatures with the goal to reach …

    ubc Repository record for Resurrecting the N = 20 shell closure and upgrades to the TITAN measurement Penning trap (opens in a new tab) Download PDF for Resurrecting the N = 20 shell closure and upgrades to the TITAN measurement Penning trap (opens in a new tab)

  7. Precise mass measurements of Cf252 fission fragments with the Canadian penning trap mass spectrometer (CPTMS)

    The Canadian Penning Trap Mass Spectrometer (CPTMS) located at the ATLAS (Argonne Tandem Linear Accelerator System) facility of Argonne National Laboratory makes precise mass measurements on both stable and unstable isotopes. A 252Cf fission source has been used as the ion source for the unstable …

    manitoba Repository record for Precise mass measurements of Cf252 fission fragments with the Canadian penning trap mass spectrometer (CPTMS) (opens in a new tab)

  8. A cooler Penning trap to cool highly charged radioactive ions and mass measurement of 24Al

    Penning trap mass spectrometry (PTMS) can be used to test the Standard Model (SM) and to answer the questions related to the origin and abundance of the elements in the universe. There are several facilities worldwide specialized in PTMS and some of them can measure the masses of isotopes with …

    manitoba Repository record for A cooler Penning trap to cool highly charged radioactive ions and mass measurement of 24Al (opens in a new tab)

  9. Study of the decay of Zr-96 by isotope geochemistry and Penning trap mass spectrometry

    … decay Q-values were measured using the JYFLTRAP mass spectrometer. This measurement significantly improved the Q-value uncertainties over previous measurements, refining the underlying nuclear theory to improve understanding of the single-ß decay path of 96Zr->96Nb. A study of the …

    calgary Repository record for Study of the decay of Zr-96 by isotope geochemistry and Penning trap mass spectrometry (opens in a new tab)

  10. A mass measurement of the short-lived halo nucleus ¹¹Li with the TITAN Penning trap spectrometer

    … were made using recently commissioned TITAN Penning trap mass spectrometer at TRIUMF. The measurement of the halo nucleus ¹¹Li represents a new standard in Penning trap mass spectrometry, as it is the shortest lived, t₁/₂ = 8.8 ms, isotope ever weighed using this technique. Low energy, E = 20 …

    ubc Repository record for A mass measurement of the short-lived halo nucleus ¹¹Li with the TITAN Penning trap spectrometer (opens in a new tab) Download PDF for A mass measurement of the short-lived halo nucleus ¹¹Li with the TITAN Penning trap spectrometer (opens in a new tab)

  11. Investigation of Background from the Inter-Spectrometer Penning Trap and Secondary Electron Emission in the KATRIN Experiment

    … geometry of KATRIN is the inter-spectrometer Penning trap formed during tandem operation of the spectrometers. Detailed measurements and simulations were performed to quantify the background induced by the Penning trap and to confirm the electron-production model. However, by maintaining …

    washington Repository record for Investigation of Background from the Inter-Spectrometer Penning Trap and Secondary Electron Emission in the KATRIN Experiment (opens in a new tab)

  12. First mass measurements of highly charged, short-lived nuclides in a Penning trap and the mass of 74Rb

    … best determined by direct mass measurements in Penning traps. In this work, Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions, using the TITAN facility. Compared to singly-charged ions, this provides an improvement in …

    ubc Repository record for First mass measurements of highly charged, short-lived nuclides in a Penning trap and the mass of 74Rb (opens in a new tab) Download PDF for First mass measurements of highly charged, short-lived nuclides in a Penning trap and the mass of 74Rb (opens in a new tab)

  13. Mass measurements of neutron-rich nuclides for the astrophysical r process using the Canadian Penning trap mass spectrometer

    … before they are sent to the Canadian Penning trap (CPT) mass spectrometer, where their masses are measured using the Phase-Imaging Ion-Cyclotron- Resonance (PI-ICR) technique. The main focus of this work was to provide data on atomic masses that would allow simulations to replicate the …

    manitoba Repository record for Mass measurements of neutron-rich nuclides for the astrophysical r process using the Canadian Penning trap mass spectrometer (opens in a new tab)

  14. Mass measurement of the lightweight self-conjugate nucleus zirconium-80 and the development of the single ion penning trap

    … are fundamental for nuclear physics research. Penning trap mass spectrometry (PTMS) is currently the most precise method for performing these measurements. The Low Energy Beam and Ion Trap (LEBIT) Facility at the National Superconducting Cyclotron Laboratory (NSCL) uses PTMS to measure the …

    msu Repository record for Mass measurement of the lightweight self-conjugate nucleus zirconium-80 and the development of the single ion penning trap (opens in a new tab)

  15. Towards high precision mass measurements of short-lived exotic isotopes using highly charged ions at the TITAN Penning trap system

    The TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) experiment will use Penning trap (PT) for precise mass determinations on short-lived isotopes at ISAC. An Electron Beam Ion Trap (EBIT) is used to charge breed ions to a charge state q. The PT mass resolution is directly proportional to …

    ubc Repository record for Towards high precision mass measurements of short-lived exotic isotopes using highly charged ions at the TITAN Penning trap system (opens in a new tab) Download PDF for Towards high precision mass measurements of short-lived exotic isotopes using highly charged ions at the TITAN Penning trap system (opens in a new tab)

  16. First direct mass measurement of the two and four neutron halos ⁶He and ⁸He using the TITAN Penning trap mass spectrometer

    … = 808 ms, 119 ms respectively) using the TITAN Penning trap as well as systematic studies of this system. The obtained mass are m(⁶He) = 6 018 885.883(57) u and m(⁸He) = 8 033 934.435(114) u. These values show deviations with literature of 4.0 and 1.7σ. Using our new masses, we re-evaluated the …

    ubc Repository record for First direct mass measurement of the two and four neutron halos ⁶He and ⁸He using the TITAN Penning trap mass spectrometer (opens in a new tab) Download PDF for First direct mass measurement of the two and four neutron halos ⁶He and ⁸He using the TITAN Penning trap mass spectrometer (opens in a new tab)

  17. Staking out the Tm Proton drip-line with mass spectrometry and using electrons to sympathetically cool ions inside a penning trap

    … trends in their relative stability. Modern ion trapping techniques such as Penning Trap Mass Spectrometry (PTMS), and Multiple Reflection Time Of Flight Mass Spectrometry (MRTOF-MS) have enabled the precision measurement of energy trends in even very short-lived nuclei, by allowing their masses …

    manitoba Repository record for Staking out the Tm Proton drip-line with mass spectrometry and using electrons to sympathetically cool ions inside a penning trap (opens in a new tab)

  18. Radio-frequency generation of an electron plasma in a Malmberg-Penning trap and its interaction with a stationary or pulsed electron beam.

    Experiments and numerical investigations on trapped electron plasmas and traveling electron bunches are discussed. A Thomson backscattering diagnostics set up was installed in the ELTRAP (Electron TRAP) device, a Penning-Malmberg trap operating at the Department of Physics of the University of …

    milano Repository record for Radio-frequency generation of an electron plasma in a Malmberg-Penning trap and its interaction with a stationary or pulsed electron beam. (opens in a new tab)

Page 1 of 4