Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"Perfusion index"”
-
Φυσιολογικοί και παθολογικοί παράμετροι ροής του αρτηριακού, πυλαίου και φλεβικού συστήματος του ήπατος στην έγχρωμη doppler υπερηχοτομογραφία
… velocity (TAV) and calculation of Doppler Perfusion Index (DPI) of liver. Results: Asymptomatic HBV carriers showed statistically significant decrease in portal vein TAV (12,8±6,1 vs 17,5±8,8), increase in portal vein BF (411,38±211,31 vs 327,55±188,77) and decrease in DPI (0,18±0,14 vs …
-
Efectos de la simpatectomía torácica sobre la pletismografía de los miembros superiores en sujetos con hiperhidrosis palmar
… DC (non-pulsatile component), 3. Ratio AC / DC (perfusion index), 4. Area under the curve (AUC), 5. time between the start of the peak systolic wave (T_DA) and 6. Time between pulse wave (T_DD). Results: AC increased 120% and DC decreased 78% of the right upper extremity (RUE) with a 99% …
-
Stellenwert der modernen Ultraschalldiagnostik in der Erkennung und Klassifizierung adrenaler Raumforderungen
… werden: Peak-Enhancement [%], Wash-in Perfusion Index [%], Wash-out AUC [%] und Wash-in and Wash-out AUC [%]. Eine weitere Unterscheidung gelang mit den Parametern Wash-in AUC [%], Wash-in-Rate [%], Wash-out-Rate [%] und Time to Peak [s]. Eine Differenzierung in verschiedene Entitäten …
-
CT perfusion image processing: analysis of liver tumors
Perfusion CT imaging of the liver has potential to improve evaluation of tumour angiogenesis. Quantitative parameters can be obtained applying mathematical models to Time Attenuation Curve (TAC). However, there are still some difficulties for an accurate quantification of perfusion parameters due, …
-
Image processing techniques in nuclear medicine
… has been investigated. <br></br><br></br>Hepatic perfusion imaging studies with <sup>99</sup>Tc<sup>m</sup>-tin colloid were performed in patients with primary colorectal carcimma. The hepatic perfusion index performed poorly in the detection of those patients with occult or overt hepatic …
-
Improving the care of preterm infants: before, during, and after, stabilisation in the delivery room
… (ECG) application warrants further evaluation. Perfusion index (PI) monitoring utilised in the delivery room was feasible. Video recording technology was utilised in several ways. This technology has many potential benefits, including debriefing and coaching in procedural healthcare, and …
-
Improving wearable out-of-hospital pulse oximetry estimation with novel real-time analysis of photoplethysmography
… to provide a result, thus failing during low perfusion states or cardiac arrest. This thesis investigates whether acute desaturation can be continuously monitored using photoplethysmography (PPG)-based devices to enable rapid detection of acute cardiopulmonary instability. To address this …
-
Comparison of Small Volume Bolus Administration of Hypertonic Saline, Colloid, and Hypertonic Saline-Colloid Combination in Dogs with Isoflurane-Induced Hypotension
… dioxide, end tidal isoflurane concentrations, perfusion index and plethysmographic variability index via pulse oximetry, mean right atrial and mean pulmonary arterial pressures, and cardiac output by thermodilution were measured.Hemodynamic parameters were assessed at baseline following 30 …
-
Die Kontrastmittelsonografie (CEUS): Evaluation der Aggressivität von Prostatakarzinomen anhand der quantitativen Perfusionsanalyse im Vergleich zur DCE-MRT
… (GS) ≥ 4+3, ≥ ISUP 3), anhand der quantitativen Perfusionsanalyse zu objektivieren. Die erhobenen CEUS-Parameter wurden darüber hinaus mit äquivalenten Parametern der dynamischen kontrastmittelverstärkten MRT (DCE-MRT) verglichen. Material und Methoden: 158 Patienten mit Verdacht auf ein PCa und …
-
Ανασκόπηση των υπαρχουσών μεθόδων αξιολόγησης του πόνου σε βαρέως πάσχοντες ασθενείς υπό μηχανικό αερισμό
… η εγκυρότητα εργαλείων όπως το BIS (Bispectral Index), η μέτρηση του αντανακλαστικού διαστολής της κόρης του οφθαλμού, PDR (Pupillary Dilatation Reflex), η μέτρηση αγωγιμότητας δέρματος στο αλγόμετρo, ο δείκτης αιμάτωσης με παλμικό οξύμετρο, το PI (Perfusion Index) καθώς και άλλες μέθοδοι που …
-
Applications of machine learning for the diagnosis of sleep apnoea and the causal analysis of sleep studies
… these experiments is not associated with the perfusion index (PI), a measure used to quantify signal quality.<br/><br/>Greater understanding of the physiological mechanisms of sleep could improve treatment. Accordingly, causal reasoning is applied to this field of study. Firstly, Granger …
-
Dynamic Imaging of Tissue Perfusion Using Ultrasound Contrast Agents
Tissue perfusion is an important indicator of the health and vitality of organs such as liver and kidney. Imaging tissue perfusion has significant clinical applications such as myocardial infarction. Contrast-enhanced ultrasound (CEUS) has been clinically used in imaging myocardial perfusion since …
-
Pulse oximetry: Evaluation of a potential tool for early detection of critical congenital heart disease
… for pulse oximetry (Paper I), normal range for perfusion index; PPI (Paper II), and deviation of pulse oximetry values from true arterial saturation in cyanosed children (Paper IV). Paper III includes a multicentre screening-study that tests the method prospectively in all newborn nurseries in …
-
MRT/Ultraschall fusionierte Biopsie und multiparametrischer Ultraschall der Prostata bei Verdacht auf ein Prostatakarzinom
… gestütztem Ultraschall und quantitativer Perfusionsanalyse im Rahmen der MRT/Ultraschall fusionierten Biopsie der Prostata eine Detektion und Prädiktion von PCa? (5.) Steigert der Einsatz zusätzlicher ventraler Biopsien in der additiv durchgeführten systematischen Biopsie die Detektion von …
-
The Association of Kangaroo Mother Care, Energy Conservation, and Bonding in Preterm Neonates
… parameters using bedside monitoring and perfusion and oxygenation of the gut using near-infrared spectroscopy (NIRS) during 1 hour of KMC compared to incubator care. Study design: A randomized controlled trial (RCT) examining the effects of 1-hour of KMC or 1-hour incubator care on …
-
Case Series: A Description of the Pleth Variability Index in Patients with Septic Shock
Pulse variability index (PVI) is a new functional hemodynamic measurement value that is noninvasive and has been shown to predict fluid responsiveness in critically ill patients. Few studies have examined the use of PVI in patients with severe sepsis or septic shock. This prospective case series …
-
Multiple contrast-bolus injection strategy for the quantification of hepatic tumor perfusion by DCE-MRI : a rabbit study
… est de plus en plus proposée pour évaluer la perfusion des cancers. Mais elle souffre d'une faible résolution temporelle, d'un faible rapport signal / bruit (SNR), d'artefacts de mouvements, et elle est particulièrement limitée par la non-linéarité de la relation signal-concentration d'agent …
-
Accuracy of Masimo Radical-7® Pulse CO-oximetryTM in anaesthetized dogs
… accuracy of SpHb and SpO2 will be influenced by perfusion index (PI), mean arterial pressure (MAP) and tongue thickness. Furthermore, clinical significance and trending accuracy were tested with error grid and four quadrant plot analysis. A total of 39 data pairs of tHb were obtained before …
-
An investigation of splanchnic blood flow in patients with colorectal cancer
… portal venous blood flow is reduced. The Doppler Perfusion Index (DPI), defined as the ratio of hepatic arterial to total liver blood flow, increases as a result of both these changes. An elevated DPI at the time of apparently curative surgery has been shown to be highly predictive of subsequent …
-
Prédiction de la réponse à l’expansion volémique : Nouvelles limites, nouvelles méthodes
… test, qui consiste en la mesure de l’indice de perfusion (IP), rapport entre la portion pulsatile et non pulsatile du signal de saturation pulsée en oxygène. Même si le signal ne pouvait pas être recueilli de façon stable chez tous les patients, les changements de cet indice lors du PLR …
Page 1 of 2