Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 87 for “"Perfusion system"”.

  1. Development of a physiologic ex vivo vessel perfusion system.

    … of MCS devices. Therefore, a unique ex vivo perfusion system integrated with a mock adult circulatory system was design to study the impact of VAD-generated flow patterns on vascular function. Methods: The benefits of a mock circulatory loop and an ex vivo perfusion system were combined by …

    louisville Repository record for Development of a physiologic ex vivo vessel perfusion system. (opens in a new tab)

  2. A PERFUSION SYSTEM WITH MONITORING DEVICES FOR OPEN-HEART SURGERY

    … the physiological aspects of heart-lung perfusion techniques concern mainly two areas connected with the extracorporeal system. These are the reduction of priming volume required in the oxygenator and the requirement for a monitored control of the blood's gas exchange parameters to …

    sask Repository record for A PERFUSION SYSTEM WITH MONITORING DEVICES FOR OPEN-HEART SURGERY (opens in a new tab)

  3. Development of an Equine Ex Vivo Pulmonary Arterial Perfusion System

    … lung preparations. An ex vivo pulmonary arterial perfusion system (EVPAPS) with controlled pulsatile flow, perfusate temperature and ventilation was designed and constructed. A blind technique for catheter placement into the distal main stem f the pulmonary artery utilizing balloon tipped …

    guelph Repository record for Development of an Equine Ex Vivo Pulmonary Arterial Perfusion System (opens in a new tab)

  4. Frequency Response Characterization for a Microprocessor-Based Coronary Perfusion System

    … development of a microprocessor-based coronary perfusion system used to enable studies of coronary circulation that are independent of the influence of the systemic circulation. A closed loop servo valve system is used to control coronary perfusion. The servo valve serves to partition blood flow …

    marquette Repository record for Frequency Response Characterization for a Microprocessor-Based Coronary Perfusion System (opens in a new tab)

  5. TUBULAR PERFUSION SYSTEM BIOREACTOR FOR THE DYNAMIC CULTURE OF HUMAN MESENCHYMAL STEM CELLS

    … have developed a novel bioreactor, the tubular perfusion system (TPS), to culture human mesenchymal stem cells (hMSCs) in three dimensional scaffolds. In our design, hMSCs are cultured on scaffolds tightly packed in a tubular growth chamber. Media is perfused by a peristaltic pump through the …

    maryland Repository record for TUBULAR PERFUSION SYSTEM BIOREACTOR FOR THE DYNAMIC CULTURE OF HUMAN MESENCHYMAL STEM CELLS (opens in a new tab)

  6. DEVELOPING A MACHINE PERFUSION SYSTEM FOR THE PRESERVATION OF RAT ABDOMINAL WALL VASCULARIZED COMPOSITE ALLOGRAFTS

    Machine perfusion (MP) systems offer a promising platform for organ preservation, providing continuous nutrient delivery, toxin removal, and treatment administration. This technology has emerged as a vital alternative to static cold storage (SCS), addressing issues related to ischemia-reperfusion …

    jhu Repository record for DEVELOPING A MACHINE PERFUSION SYSTEM FOR THE PRESERVATION OF RAT ABDOMINAL WALL VASCULARIZED COMPOSITE ALLOGRAFTS (opens in a new tab)

  7. In-Silico design and verification of an extracorporeal normothermic cardiac perfusion system for use during heart transplantation procedures

    … with cardioplegic arrest to continuous blood perfusion, which enhances metabolic support and extends viable ischemic time. This study explores the development of a system for continuous myocardial perfusion to improve donor heart preservation during transplantation. Using in-silico modelling …

    cape-town Repository record for In-Silico design and verification of an extracorporeal normothermic cardiac perfusion system for use during heart transplantation procedures (opens in a new tab)

  8. In-Silico design and verification of an extracorporeal normothermic cardiac perfusion system for use during heart transplantation procedures

    … with cardioplegic arrest to continuous blood perfusion, which enhances metabolic support and extends viable ischemic time. This study explores the development of a system for continuous myocardial perfusion to improve donor heart preservation during transplantation. Using in-silico modelling …

    cape-town Repository record for In-Silico design and verification of an extracorporeal normothermic cardiac perfusion system for use during heart transplantation procedures (opens in a new tab)

  9. IDENTIFYING FACTORS DRIVING TNF-α EXPRESSION IN THE DUAL CLOSED LOOP EX-VIVO PLACENTAL PERFUSION MODEL: A METHODOLOGICAL STUDY

    … The <em>ex-vivo</em> dual closed-loop placental perfusion model has been widely used to study placental physiology. To address the association between bacterial chorioamnionitis and fetal inflammation, TNF-α induction following lipopolysaccharide (LPS) challenge – a pyrogen of Gram-negative …

    mcmaster Repository record for IDENTIFYING FACTORS DRIVING TNF-α EXPRESSION IN THE DUAL CLOSED LOOP EX-VIVO PLACENTAL PERFUSION MODEL: A METHODOLOGICAL STUDY (opens in a new tab)

  10. Vývoj ex vivo plicního perfuzního systému pro animální modely

    … time and so follow the principles of the 3Rs, a perfusion system is involved in the procedure. The perfusion system filled with a chosen perfusate solution is responsible to prolong the period in which the animal lungs are viable for experiments and storage in the ex-vivo environment. The …

    brno-tech Repository record for Vývoj ex vivo plicního perfuzního systému pro animální modely (opens in a new tab)

  11. The Effect of Architecture and Shear Stress on Endothelialization of 3D Printed Vascular Networks

    … with this challenge. Specifically, the tubular perfusion system bioreactor has been used for large scale bone constructs; however these engineered constructs lack inherent vasculature and quickly develop a hypoxic core, where no nutrient exchange can occur, thus leading to cell death. Through …

    maryland Repository record for The Effect of Architecture and Shear Stress on Endothelialization of 3D Printed Vascular Networks (opens in a new tab)

  12. Design and development of a bioreactor for ligament tissue engineering

    … reactor vessels, with enhanced environmental and perfusion fluidic control under sterile conditions. The cell seeding and perfusion system is made of polycarbonate and is translucent. The whole system consists of four cell seeding chambers that can be incorporated into the perfusion system whereby …

    nus Repository record for Design and development of a bioreactor for ligament tissue engineering (opens in a new tab) Download file for Design and development of a bioreactor for ligament tissue engineering (opens in a new tab)

  13. Development of a Phantom Tissue for Blood Perfusion Measurements and Noninvasive Blood Perfusion Estimation in Living Tissue

    … method for testing and calibrating surface perfusion sensors has been developed. A phantom tissue model is used to mimic the non-directional blood flow of tissue perfusion. A computational fluid dynamics (CFD) model was constructed in Fluent to design the phantom tissue and validate the …

    vt Repository record for Development of a Phantom Tissue for Blood Perfusion Measurements and Noninvasive Blood Perfusion Estimation in Living Tissue (opens in a new tab)

  14. Development of the Passive Perfusion Probe for Non-Invasive Blood Perfusion Measurement

    A non-invasive blood perfusion system has been developed and tested in a phantom tissue and an animal model. The system uses a small sensor with a laminated flat thermocouple to measure the heat transfer response to an arbitrary thermal event (convective or conductive) imposed on the tissue …

    vt Repository record for Development of the Passive Perfusion Probe for Non-Invasive Blood Perfusion Measurement (opens in a new tab)

  15. Triple-Negative Breast Cancer Spheroids in a Dynamic Pillar-Perfusion Platform for Evaluating Enzyme-Induced Self-Assembling Peptide Therapeutics

    … were established and integrated into a pillar/perfusion system via hydrogel embedding to emulate the key features of the tumor microenvironment (TME). Hydrogel optimization enabled spheroid stability and phenotype control, revealing both invasive and non-invasive behaviors depending on the …

    unt Repository record for Triple-Negative Breast Cancer Spheroids in a Dynamic Pillar-Perfusion Platform for Evaluating Enzyme-Induced Self-Assembling Peptide Therapeutics (opens in a new tab)

  16. The development and clinical application of small intestinal perfusion studies in man

    … is the technique of small intestinal marker-perfusion applied to the measurement of jejunal absorption in man. The work describes studies performed in developing the technique and applying it to study factors involved in influencing intestinal absorption. Standard methods of investigating …

    glasgow Download PDF for The development and clinical application of small intestinal perfusion studies in man (opens in a new tab)

Page 1 of 5