Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 109 for “"Perimetry"”.
-
Data-Driven Portable Perimetry
Automated visual field testing, or perimetry, is a non-invasive method to assess differential light sensitivity across the retina. Traditionally, perimetry has been confined to clinical settings which are highly controlled. However, recent advancements in portable perimetry have expanded the …
-
Improving measurements in perimetry for glaucoma
… and, if untreated, irreversible blindness. Perimetry is the clinical tool for assessing the functional ‘seeing’ part of the field of view (visual field) and is widely used in the detection and clinical monitoring of glaucoma. These measurements rely on a psychophysical response making them …
-
Saccadic vector optokinetic perimetry : a technique and system for automated static perimetry in children using eye tracking
Perimetry is essential to identify visual field defects in disorders of the visual pathways. In compliant adults, automated static perimetry (ASP) is the preferred method of visual field assessment. However, children under 10 years have difficulty with the visuo-motor task and constant fixation …
-
Examination variability in short-wavelength automated perimetry
… variability in standard white-on-white (W-W) perimetry and short-wavelength automated perimetry (SWAP). The Influence of staircase strategy on the fatigue effect in W-W perimetry was investigated for a 4 dB single step, single reversal strategy; a variable step size, single reversal dynamic …
-
Retinal Diseases: multifocal pupillographic objective perimetry, and epidemiology
… with multifocal pupillographic objective perimetry (mfPOP) in neovascular AMD (nAMD) and diabetic macular oedema (DMO), and second, epidemiology of vitreoretinal diseases (VRD) in Bhutan and Nepal. The epidemiological chapters cover 1905 new VRD patients in Nepal, and 2913 in Bhutan. Those …
-
Multifocal pupillographic objective perimetry in age-related maculopathy
… potential of multifocal pupillographic objective perimetry (mfPOP) in AMD. Our investigation began with the determination of the optimal features for centrally directed stimuli in multifocal pupillography. To overcome the effects of saturation and achieve high signal to noise ratios from stimuli …
-
The evaluation of multiple sclerosis through static chromatic perimetry
… luminance thresholds through static, chromatic perimetry could be used to distinguish visual threshold losses in multiple sclerosis from that of normal functioning. It was proposed that threshold losses would be greater at both the fovea and near foveal eccentricities due to the assumption that …
-
Regression Analysis of Censored Data with Applications in Perimetry
This thesis treats regression analysis when either the dependent or the independent variable is censored. We deal with quantile regression when the dependent variable is censored. Using the independence between the true values and the censoring limits the quantile function for the true values can …
-
Reclaiming the periphery: Kinetic perimetry in patients with glaucoma
Static automated perimetry of the central 30˚ is the most often used visual field test in glaucoma patients. Short test durations are achieved by focusing on a central region, which constitutes ~20% of the visual field. However, ignoring the periphery may sacrifice information on how patients are …
-
Psychophysical aspects of clinical perimetry: studies in ageing and disease
… be addressed in the use of conventional clinical perimetry techniques include: How does CS change with age across the VF? Are static and kinetic perimetry results actually the same? Can factors causing increased measurement variability in perimetry be systematically quantified and eliminated? …
-
Aspects of frequency doubling perimetry in the detection of early glaucoma
Background : Frequency Doubling Perimetry ( FDP ) is a recently developed form of perimetry, which may be more sensitive for detecting visual field loss from glaucoma than conventional Achromatic Automated Perimetry ( AAP ). This thesis was undertaken to study aspects of FDP for the detection of …
-
The role of standard automated perimetry in age-related macular degeneration
Standard automated perimetry (SAP) is a well-established test of visual function, Goldmann size III (GIII) being the standard stimulus size used. Studies have shown that using GIII across the visual field (VF) may however result in lower separability between normals and those with optic nerve …
-
A comparison of two fast threshold strategies, SPARK and SITA in threshold perimetry
This thesis investigated the extent of differences between a newer fast threshold strategy, SPARK and the “gold standard” strategy, Swedish Interactive Threshold Algorithm (SITA). A between-visit comparative study in subjects with glaucoma and suspected glaucoma, subjects with cataract and healthy …
-
Estimating Retinal Ganglion Cell Content with Widefield OCT and Perimetry in Non-Human Primates
… and visual sensitivity from Standard Automated Perimetry (SAP) using stimulus sizes I-V. The histological correspondence of these in-vivo measures was obtained at the endpoint in a non-human primate (NHP) experimental glaucoma model. Methods: 1) Widefield and standard OCT scans were acquired in …
-
Automated static perimetry and dimensional characteristics of the intra- and peri-papillary retinal features in myopia
… the central visual field by automated static perimetry in a group of healthy myopic individuals with peripapillary crescents and tigroid fundus changes only. The appearance of the optic nerve head and surrounding structures were used to classify subjects into groups for the analysis of field …
-
Exploring the Relationship Between Health Biomarkers and Performance on a Novel Color Perimetry Device in Prediabetes and Type 2 Diabetes
… present. Here we evaluate whether a novel color perimetry device could be used as an indicator of health changes in the eye along with alterations of diabetes status and other health biomarkers. Methods: 40 (age-matched) subjects were divided into three groups by HbA1c or previous diagnosis …
-
Virtual reality goggles for visual field diagnostics
Current methods of perimetry testing present substantial difficulties with regards to patient fatigue and cooperation. This project aims to implement the building block for a game-like perimetry test in virtual reality, which aims to improve the patient compliance. The game elements have been …
-
Συγκριτική μελέτη με οπτικά προκλητά δυναμικά, οπτικά πεδία, μαγνητική τομογραφία οπτικού νεύρου και μαγνητική τομογραφία εγκεφάλου ασθενών με πρώτο κλινικό επεισόδιο οπισθοβολβικής νευρίτιδος
… and the optic nerve), with evoked potentials and perimetry. All above examinations were performed in both affected and partner eye in the acute phase and one month after. 100% revealed abnormal evoked potentials, 80% revealed abnormal perimetry, 78% revealed demyelinating plaques in brain magnetic …
-
Evaluation of hemifield sector analysis protocol in multifocal visual evoked potential (MFVEP) objective perimetry for the diagnosis and early detection of glaucomatous field defects
… and monitoring, and the Standard Automated Perimetry (SAP) test is considered up until this moment, the gold standard of visual field assessment. Although SAP is a subjective assessment and has many pitfalls, it is being constantly used in the diagnosis of visual field loss in glaucoma. …
-
Examining the effect of test stimulus size and movement on the detection of contrast in visual field testing
… locations across the visual field (static perimetry) or by moving a spot of light across the visual field until it is visible (kinetic perimetry). Despite the popularity of visual field testing in both research and clinical assessment, a number of limitations have been noted with both …
Page 1 of 6