  1. The Use of Periotest as a Diagnostic Tool in Endodontics

    Introduction: Periotest is a device that measures the damping characteristics of the periodontium. It has a tapping head which percusses the tooth 16 times in 4 seconds. This sensitive tip records the duration of contact with the tooth and gives us a reading. The Periotest value (PTV) is ranging …

    temple Repository record for The Use of Periotest as a Diagnostic Tool in Endodontics (opens in a new tab)

  2. Assessing the Initial Primary Stability of Dental Implants via Various Osteotomy Preparation Techniques: An Ex Vivo Comparative Study Utilizing Two Distinct Non-Invasive Methods

    … . Two innovative noninvasive devices like Periotest® (Siemens AG, Bensheim, Germany) and resonance frequency analysis (RFA) (Osstell Mentor) (Integration Diagnostics AB, Göteborg, Sweden) have been introduced to measure implant primary stability. The aim of this study is to assess and …

    buffalo Repository record for Assessing the Initial Primary Stability of Dental Implants via Various Osteotomy Preparation Techniques: An Ex Vivo Comparative Study Utilizing Two Distinct Non-Invasive Methods (opens in a new tab)

  3. New In Vivo and In Vitro Techniques for Quantification of Lateral Force Levels That Cause Implants to Fail : A Progress Report on Monkey Research

    … with no increase in mobility as verified by a Periotest device. No previous studies on the orthodontic uses of implants have evaluated in vivo forces of this magnitude in monkeys, used strain gages in quantification of applied loads, nor have they quantified mobility in terms of Periotest …

    loma-linda Repository record for New In Vivo and In Vitro Techniques for Quantification of Lateral Force Levels That Cause Implants to Fail : A Progress Report on Monkey Research (opens in a new tab)

  4. Factors effecting primary stability of mini-implants in vitro

    … procedures. PS of MIs was measured with Periotest and Osstell by three testers. The Cronbach Alpha inter-examiners reliability test was used to evaluate agreement among the testers. PS data were analyzed with multifactorial ANOVA to detect the significant influence of each factor in MIs’ …

    ubc Repository record for Factors effecting primary stability of mini-implants in vitro (opens in a new tab) Download PDF for Factors effecting primary stability of mini-implants in vitro (opens in a new tab)

  5. In Search of An Improved Methodology for Measuring Dental Implant Stability: Combining Experimental Model Analysis (EMA) and Finite Element Analysis (FEA) to Achieve Maximum Reliability

    … implant stability devices—the Osstell ISQ®, the Periotest®, and the Periometer—by calibrating them via both EMA and FEA, using models of dental implants of various lengths in Sawbones® of different densities. The theoretical mechanics used to operate the three devices were analyzed to understand …

    washington Repository record for In Search of An Improved Methodology for Measuring Dental Implant Stability: Combining Experimental Model Analysis (EMA) and Finite Element Analysis (FEA) to Achieve Maximum Reliability (opens in a new tab)

  6. Estabilidade primária de implantes imediatos em comparação com implantes instalados em áreas edêntulas : uma revisão sistemática e metanálise

    … frequência de ressonância, torque de inserção e Periotest. Outras subanálises foram realizadas para investigar os fatores que podem afetar o resultado. As metanálises foram realizadas sempre que possível. De 3413 títulos encontrados, 4 estudos randomizados e 3 não randomizados foram incluídos, …

    brazil-ufrgs Repository record for Estabilidade primária de implantes imediatos em comparação com implantes instalados em áreas edêntulas : uma revisão sistemática e metanálise (opens in a new tab)

  7. Comparison of piezoimplants versus conventional cylindrical implants in minipigs: stability analysis

    … tests (three per implant) using wireless Periotest® “M” were done at the start point and after euthanization. RESULTS: R-square (ANOVA) test was plotted comparing implant design, weeks 4, 8 and 12, and location (mandible and maxilla) for stability analysis. In this model, the R-square is …

    bu Repository record for Comparison of piezoimplants versus conventional cylindrical implants in minipigs: stability analysis (opens in a new tab)

  8. Einfluss der bukkalen Knochenlamelle auf die Hart- und Weichgewebsheilung bei Sofortimplantation mit offener und geschlossener Einheilung

    … implants demonstrated clinical stability (Periotest). Despite GBR failures caused by the pigs’ hay consumption after one week, no significant differences (p > 0.5) were observed between SM-BD and NSM-BD in buccal parameters (NSM-BD/SM-BD: S=0.6 mm, IE=2.9/2.4 mm, CT=3.5/3.4 mm, BW=5.9/5.8 …

    cau-kiel Repository record for Einfluss der bukkalen Knochenlamelle auf die Hart- und Weichgewebsheilung bei Sofortimplantation mit offener und geschlossener Einheilung (opens in a new tab)

  9. An Immediate Implant Stability and Pull-Out Study Comparing Two Different Surgical Techniques : Conventional Drilling versus Trabecular Compaction : A Pilot Study

    … The initial lateral stability (assessed by Periotest values, PTVs), the uniaxial pull-out force (measured by Instron machine) and the radiodensity (Hounsfield numbers) of immediately placed implants were investigated in a split mouth design. The mean PTV of implants placed by the trabecular …

    loma-linda Repository record for An Immediate Implant Stability and Pull-Out Study Comparing Two Different Surgical Techniques : Conventional Drilling versus Trabecular Compaction : A Pilot Study (opens in a new tab)

  10. Experimental Peri-Implant Tissue Breakdown in Rhesus Monkeys

    … with no significant difference between mean Periotest values at baseline and at follow-up examinations. The peri-implant subgingival microflora at baseline was dominated by coccoid cells. Following ligature placement, the microflora included a large proportion of Gram-negative anaerobic rods, …

    loma-linda Repository record for Experimental Peri-Implant Tissue Breakdown in Rhesus Monkeys (opens in a new tab)

  11. Immediate Loading of Unsplinted Implants in the Anterior Mandible for Overdentures

    … level via standardized periapical radiographs, Periotest values (PTV), modified plaque index (mPI), surgical and prosthetic complications. All implants were successfully osseointegrated (16/16) with a follow-up time of 12-months. The mean marginal bone levels at 0-, 3-, 6-, and 12-months were …

    loma-linda Repository record for Immediate Loading of Unsplinted Implants in the Anterior Mandible for Overdentures (opens in a new tab)

  12. Immediate Provisionalization of Single 3.0 mm Diameter Implant in Maxillary and Mandibular Anterior Region

    … was evaluated at time of implant placement and Periotest values (PTVs) were recorded at 0- and 3-months follow-up. All implants were functioning at 12-months follow up indicating a success rate of 100% (13/13). Mean and SD of the marginal bone level at 0-, 3-, 6-, and 12-months were -0.03 ±0.10 …

    loma-linda Repository record for Immediate Provisionalization of Single 3.0 mm Diameter Implant in Maxillary and Mandibular Anterior Region (opens in a new tab)

  13. Periimplantäre Mukositis

    … die Beweglichkeit mit Hilfe des Periotests (Periotest ®M, Medizintechnik Guldene K, Germany) und der Klopfschall bei allen Patienten erhoben. Das Vorliegen einer Mukositis verursachte nach der Evaluation mit dem OHIP keine signifikante Einschränkung der oralen Lebensqualität. In …

    cau-kiel Repository record for Periimplantäre Mukositis (opens in a new tab)

  14. Biomechanical and histological evaluation of a new zirconia implant in a canine model

    … rate (MAR), bone forming area (BFA), and Periotest value (PTV) of the two groups were studied and compared. Results: At 12 weeks post operatively, one Shofu thread type Ti implant were not integrated. Over all failure implant was 0/12 in zirconia group, and 1/12 in titanium group. In 8 …

    iupui Repository record for Biomechanical and histological evaluation of a new zirconia implant in a canine model (opens in a new tab)